Loading...
HomeMy WebLinkAbout03090025 St. Christopher Episcopal Church Exapnsion pg. H1' :72 ler :1 I TE irik 1191Wra 1111MIATAL red l ariarr sin 1' tI 1 N li jam■ jwr_ ■jilt jam■ jam■ jl�`j j■ �■�i■■ ��`�i■�l ■�n I jJ g Pr '.111 1 1111---- 1- 111 1111 iA .f li 1 24 SPACES NU". ...1"11 I 1111 4010 lall IIII xi t 11 r N1' ►:t am �:1 S ri -:i� I' '_I,■_ ■■■I ■u...„., 11 i w '11" 1 I 1 ■IL 11111. FL= 868.65' j 11 FL= 869.25 LP 1 j� ft, I.. .1 1 N. 1�/1� ■I 870 J 287.11.9 870 871 N EN 7 I 8 7 Nil' ■�■■gaia diam mom ■a ti■ ittttt Iva I.; 68 SPACES 873 FL= 871.90' FL= 869.65' FL= 870.05' FL= 867.20' Drain Vent Pipe e3c Marker Sign EXIST. LIGHTPOLE TO REMAIN CONNECT DRIVE TO EXISTING PARKING LOT 1/2" Pipe Fou 3/4" Pi Ite Found 171-- 1111— 1111 0 W W r r 8 AM r r r r oe r ,1111 r r r Point of Beginnin r r i 5 8" f bar w/C p Set 5/8" Rebar w /Cap Set MEM r r r r r by H 2 873 1/2" Pipe Found 0.4' South of R/W Line FIRE HYDRANT OMB 131st Street l r 872 Apparent 16.5' Half Rig of Way r 41178�111=10 0 1 W W i 87 4 MOND PHASE 1 (CLASSROOMS BLDG.) F.F. 875.00 W 874 I— GRADING AND UTILITY PLAN -lb& 30_o H S 88 °55 E 460.23' ckD 87 3 PRopnSF[) GRFASF TRAP SEE PLUMBING DETAILS HOOK -UP FOR BUILDING SEE PLUMBING DETAILS OH L 869 W W W 868 CONNECT TO "FUTURE" CARMEL SEWER EXTENSION W 7r co W FL= W68.20' 11111111101, =IMO CONNECT TO EXISTING CARMEL WATER MAIN EXTENSION 90 UTILITY R/W 0 00 69.55' 00 (0 00 o 00 cO 1 001 0 0 cn L NI 0 Ira (0 00 0 1/2" Pipe Found 0.20' East of Line FL= 866.85' Fence Post on Line OH FIRE HYDRANT NOTES 1. PROVIDE POSITIVE DRAINAGE IN ALL AREAS. PAVING CONTRACTOR TO SHALL TEST FOR ANY POUNDING AREAS AFTER INSTALLATION AND CORRECT DEFICIENT AREAS. 2. PROVIDE SMOOTH TRANSITIONS FROM NEW AREA TO EXISTING FEATURES AS NECESSARY. 3. ALL AREAS WHERE PROPOSED ASPHALT PAVEMENT MEETS THE EXISTING PAVEMENT, THE EXISTING PAVEMENT EDGE SHALL BE PROPERLY SEALED WITH TACK COAT MATERIAL. THIS INCLUDES NEW ASPHALT WHICH HAS COOLED OR BETWEEN LIFTS. 4. THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHILE EXCAVATING AROUND EXISTING TREES SO AS NOT TO DISTURB AND TO MINIMIZE OR ELIMINATE DAMAGE TO THE ROOT SYSTEM. 5. THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHEN EXCAVATING IN OR AROUND EXISTING UTILITY LINES AND EQUIPMENT. VERIFY COVER REQUIREMENTS BY THE UTILI1Y CONTRACTOR AND/OR UTILITY COMPANIES SO AS NOT TO CAUSE DAMAGE. 6. THE EXCAVATING CONTRACTOR OR LANDSCAPING CONTRACTOR SHALL INSTALL THE FINISH GRADE AT 1/2" BELOW PAVEMENT WHEN SHEET DRAINAGE IS PROPOSED ACROSS THAT SEEDED AREA. 7. ALL AREAS WHERE THE EXISTING PAVEMENT OR PAVEMENTS ARE DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY THE GENERAL CONTRACTOR, SUBCONTRACTORS, OR SUPPLIERS THESE AREAS SHALL BE RESURFACED OR RECONSTRUCTED AT LEAST TO THEIR ORIGINAL CONDITION AFTER THE CONSTRUCTION WORK IS COMPLETED. 8. NO GRADING, EXCAVATION, OR STOCKPILING SHALL OCCUR WHEN THE AREA IS MARKED AS A LEGAL DRAIN. LEGEND vc D PROPOSED EXISTING CONTOURS PROPOSED CONTOURS W EXISTING WATER LINE W PROPOSED WATER LINE PROPOSED SANITARY SEWER EXISTING OVER HEAD UTILITY TOP OF CURB TOP OF PAVEMENT PROPOSED CULVERT FLOW DIRECTION PROPOSED SANITARY MANHOLE Date Drawn Sheet No. WOOLLEN, MOLZAN AND PARTNERS, INC ARCHITECTUR 47 South Pennsylvania Street Suite 1000 Indianapolis, IN 462 317.632.7484. 317.687.2064 (fax) www.woollenmolzan.cc Civil Structural Engineers ARSEE ENGINEERS, INC. 9715 KINCAID DRIVE, SUITE 100 FISHERS, INDIANA 46038-9459 Telephone: (317) 594-5152 Fax: (317) 594-9590 E-mail: Imodlin@arsee-engineers.com Mechanical/ Electrical Plumbing Engineers R.E. Dimond and Associates, Inc. Consulting Engineers 732 North Capitol Avenue Indianapolis, Indiana 46204 Telephone: (317)634-4672 Fax: (317)638-8725 L.) lac ma; kig) cu tic +.1.• WI eV p INC 0 2 L kid 'aig et; tin EA IP 7 6,• i +ma 0111 (10 LIU 6 Certified by MAO rawing Name REDESIGN SEPTEMBER 4, 2003 Checked GRADING AND UTILITY PLAN