Loading...
HomeMy WebLinkAboutSite Plans 10 of 10 Construction DetailsD C C B C B C B A B A "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY #8 CRUSHED STONE (1/4" TO 3/4 HEAVY DUTY PAVEMENT SECTION TYPICAL PAVEMENT SECTION EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE SIMILAR STRUCTURE IN THE PUBLIC RAN 5' OR LESS MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH #11 OR #12 SURFACE #5 BASE ASPHALT #53 COMPACTED AGGREGATE #2 COMPACTED AGGREGATE COMPACTED WELL DRAINED SUBGRADE #11B SURFACE #9 BINDER m #53 STONE #2 STONE 6" COMPACTED WELL DRAINED SUBGRADE WITHIN 5' OF EDGE OF PAVEMENT Bo OUTSIDE DIAMETER D INSIDE DIAMETER NOTE: ALL BEDDING BACKFILL TO 12" ABOVE PIPE SHALL BE IN 6" LIFTS. MIN. 12" OR 6" MIN. REGULAR BACKFILL #8 CRUSHED STONE (1/4" TO 3'4 PAVEMENT SECTION FOR 10' ASPHALT PATH EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE GREATER THAN 5' MIN. 2' Bo MAX. 3' Bc V Bc OUTSIDE DIAMETER D INSIDE DIAMETER GREATER THAN 5' FROM EDGE OF PAVEMENT NOTE: ALL BEDDING BACKFILL TO 12" ABOVE PIPE SHALL BE IN 6" LIFTS. SANITARY SEWER BEDDING DETAIL #11B SURFACE c' I #9 BINDER #53 STONE 6° COMPACTED WELL DRAINED SUBGRADE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH MIN. 12" OR 6" MIN. "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY 'A. 'A :A• e• EDGE OF PAVEMENT, CURB, GUTTER, OR SIMILAR STRUCTURE IN THE PUBLIC R W 5' OR LESS AVEMENT ON BASE SECTION A-A NOTE: ALL BEDDING INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS MIN. 9" CLEARANCE EACH SIDE OF INSTALLED PIPE DEPTH FOR BEDDING LEGEND MATERIAL BELOW PIPE Bc OUTSIDE DIAMETER D INSIDE DIAMETER d DEPTH OF BEDDING MATERIAL BELOW PIPE D 27" SMALLER 30" TO 60" 66" LARGER COMPACTED GRANULAR FILL 4" CONCRETE SLAB ON 4° #53 STONE COMPACTED SIDEWALK RAMP DETAIL MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT (d) MIN. 3" 6" REINFORCED CONCRETE PIPE (RCP) TRENCH DETAIL WITHIN 5' OF EDGE OF PAVEMENT SERVICE FROM BUILDING 18" R HANDICAP SYMBOL II III III III III CLEANOUT DETAIL CLEANOUT ADAPTOR WITH THREADED CAP 6 "x6" PVC WYE BRANCH RISER PIPE TO BE SAME SIZE AND SPECIFICATION AS HORIZONTAL PIPE d TO GRAVITY SEWER a 0 PORTLAND CEMENT 3500 PSI CONCRETE 1 /4" PER Ft. 3' FROM BUILDING (TYPICAL) 0 0 e e e e a a PLAN 0 0 STRAW BALE INLET PROTECTION NO SCALE SANDBAG DROP INLET PROTECTION A A 6" GRANULAR BACKFILL A MIN. 6" DIA. PIPE CLEANOUT SHALL BE INSTALLED WITHIN THREE (3) FEET OF OUTSIDE BUILDING WALL. A PLUG SPECIFIED BY THE PIPE MANUFACTURER SHALL BE USED TO ENSURE 100% WATERTIGHTNESS. BELL HOLES SHALL BE PROVIDED UNDER PIPE STAKED STRAW BALES TWO STAKES PER BALE) TAMPED EARTH DROP INLET WITH GRATE VARIES (SEE PLANS) 1/8 BEND ELEVATION A e e e „p PLAN VIEW ELEVATION 1/2" SCORE A• FILLED SAND BAGS STACKED AND TIGHTLY FITTED AROUND PERIMETER OF INLET TO PREVENT SEDIMENT WASH INTO INLET 1/8" R TRUNK LINE LATERAL MINIMUM SIZE 6" 1/8 BEND SERVICE WYE 1" C. I. LOCATOR ROD OR MAGNETIC TAPE INSTALLED PER SECTION 7.02 -C s 1. 1 1IN•1114 1•∎11 MIN. FALL 444# 0.61%, SERVICE CONNECTION FOR SHALLOW SEWERS (LESS THAN 15' DEEP) Alr D R 1" INTEGRAL WALK AND CURB DETAIL ai11wrn eilipmwr COMPACTION OF GRANULAR BACKFILL IS CRITICAL UNDER WYE AND BEND. IF PROPER COMPACTION CANNOT BE ACHIEVED, PLACE A MIN. OF 6" OF CLASS B CONCRETE AROUND 1/8 BEND. \i j BUILDING LATERAL MINIMUM SIZE 6" 1 STAPLE PER SO. YD. X X N X 4 X x x� n X X x X XT X X x X n ;:rX X X g _O" 1 1 /2' 1 1 /2 X B X X 1* STAPLES PER SQ. YD. X j X X R1 -0 20" X X x x x X X X X X X X X X X 2 STAPLES PER 3* STAPLES PER SQ. YD. SQ. YD. 10' MIN. CENTER OF SEWER MAIN LAYING LENGTH MEDMIGH FLOW CHANNEL SHORELINE LOW FLOW CHANNEL w 5 2:1 a O J G7 1:1 3:1 4:1 SANITARY SEWER MAIN 0 u 0 L O L( O in O C� N N CV N T T tO STAPLE PATTERN Ill— Ill WATER MAIN i 18" MIN. SLOPE LENGTH COMPACTED SUBGRADE THE UPPER 6 INCHES SHALL COMPLY WITH THE DENSITY REQUIREMENTS OF THE CONTRACT IMMEDIATELY PRIOR TO PLACING THE MATERIAL THEREON. ALL SOFT,YIELDING OR UNSUITABLE MATERIAL, WHICH CANNOT BE COMPACTED SATIFACTORILY, SHALL BE REMOVED. ALL ROCK ENCOUNTERED SHALL BE REMOVED OR BROKEN OFF AT LEAST 6 INCHES BELOW THE SUBGRADE SURFACE, ANY HOLES OR DEPRESSIONS RESULTING FROM THE REMOVAL OF UNSUITABLE MATERIAL, SHALL BE FILLED WITH SATISFACTORY MATERIAL AND COMPACTED TO CONFORM WITH THE SURROUNDING SUBGRADE SURFACE, WHERE SIDEWALK IS CONSTRUCTED ADJACENT TO THE CURB, THE SPACE BEHIND THE NEW CURB SHALL BE FILLED W111-I GRANULAR MATERIAL TO THE REQUIRED ELEVATION AND COMPACTED IN LAYERS NOT TO EXCEED 4° WHERE SIDEWALK IS NOT CONSTRUCTED ADJACENT TO THE CURB THE SPACE BEHIND THE CURB SHALL BE FILLED WITH SUITABLE MATERIAL TO THE REQUIRED ELEVATION AND COMPACTED IN LAYERS NOT TO EXCEED 4 6" VERTICAL CURB 18" MIN. WATER MAIN N LL COMPACTED, WELL DRAINED BACKFILL y SANITARY SEWER MAIN 3 MINIMUM CROSSING SEPARATION REQUIREMENTS FOR WATER SANITARY SEWER MAINS 0 a) 0) a) C!) J W Q 0 N o e .(4.:# 10 S O F ►►unnnnmt �a;, 0 0 Cn Cr) w w CC w U W C.3 0 J W CC U W W CC C� T V W LC) CD t� 0 c0 0 c0 z 0 a) .0 0 z c 0 a u- LA CO CO CO t D n .o 0 X U a) U C!) J SCALE: 1" =40' .n 0 2 a a DATE: December 5, 2003 PROJECT NO. 122-0083 2 SHEET NO. 10 OF 10 0083 -det1. DGN