HomeMy WebLinkAboutC102 Site Layout PlanX 11
gly
111111111111,1111111111111111112111146,
1111111111111
lr�tll�ll�wiltli w
!11 1111l111IREr�
�sl�rd��r11!!1111/1lMIMPt
�11■ 11liiiu ®I�c� li�fm
a
2, t rAG
FEE 807. e
FFE =Bd
PROPOSED ',r
BUILDING f
EXPANSION
,1 —e
50•.
..•••CHAIN: 4LIVK „F.
•..AROUND POND
I
C s
D
ci
1
1.350
Der
7 .95
fast 1 31 st Street
CONSTRUCTION LIMITS
06
LINE
INSTALL 42” BLACK VINYL
CHAIN LINK- NG
AR@E}N D -RCALD
WET RETENTION -841N
TOP ---OF BAN K 792.48
NORMAAk POOL ELEVATION 789.35
1 OQy FLOOD ELEVATION= 791.97
OUTLET INV =789.35
•x` 40' Half R/4
per D.R 279,pg. 74
to 7:S.hGC
NOTE:
LANE CONTROL ARROWS SHALL BE WHITE AND SHALL BE PLACED IN ACCORDANCE WITH IMUTCD.
THE ARROW SHOULD RE 20 FEET IN ADVANCE OF THE STOPLINE. THE WORD "ONLY" SHOULD BE
LOCATED IN ADVANCE C THE PAVEMENT ARROW.
792
INSTALL 42" BLACK VINYL
CHAIN LINK FENCE
AROUND POND
79
4 t ak'�
22.93
ROPOSED 50' 1/2
_1
rn
f
0
TRAFFIC MARKING DETAILS
(No SCALE)
i
m._ 7y,1
GENERAL NOTES:
1) THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE
RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO STARTING CONSTRUCTION.
2) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES IN THE VICINITY OF THE
CONSTRUCTION AREA PRIOR TO STARTING CONSTRUCTION
3) IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY AND COORDINATE CONSTRUCTION WITH ALL RESPECTIVE UTILITIES.
4) ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED
BY THE BIDDING CONTRACTORS.
5) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART
"P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH.
6) IN ADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A
REGISTERED PROFESSIONAL ENGINEER.
7) IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS PROJECT.
8) TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL STANDARDS.
9) BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR EXACT
INFORMATION.
10) ANY FIELD TILES ENCOUNTERED DURING EXCAVATION SHALL BE REPAIRED AND POSITIVE DRAINAGE PRESERVED.
11) THE ENGINEER AND /OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT.
12) THE LOWEST FLOOR ELEVATION RECEIVING GRAVITY SERVICE MUST BE A MINIMUM OF ONE (1) FOOT ABOVE THE TOP OF CASTING OF
THE NEAREST SANITARY SEWER MANHOLE, OR A GRINDER PUMP SHALL BE REQUIRED.
13) ALL DIMENSIONS ARE BASED ON FACE OF CURB OR BACK OF ROLL CURB OR FACE OF BUILDING.
14) SEE ARCHITECTURAL PLANS FOR DETAILS OF BUILDING, BUILDING DIMENSIONS, ATM RELATED DETAILS, AND SIGNAGE SPECIFICATIONS.
DO NOT STAKE BUILDING FROM THESE PLANS.
15) COORDINATE CONSTRUCTION ACTIVITIES WITH ADJOINING WORK. VERIFY EXTENT OF ADJOINING WORK AND COORDINATE AS REQUIRED.
16) FIELD VERIFY EXISTING CURBS AND TAPER PROPOSED VERTICAL CURBS TO MATCH WITHIN A MIN. OF THREE (3) FEET.
HATCH LEGEND
PROPOSED BUILDING EXPANSION
r! AREAS WHERE EXISTING ASPHALT PAVING IS TO BE
OVERLAYED WITH 1.5" OF NEW ASPHALT.
0
0
0
0 6" CONCRETE CURB SIDEWALK, REFER TO
ARCHITECTURAL DFAWINGS
PAVEMENT FLUSH Wf 1-I SIDEWALK
EXISTING SIGN
0
0
10
11
12
PLAN NOTES:
LIGHT DUTY ASPHALT PAVING
R.O.W. ASPHALT PAVING
CONCRETE SIDEWALK (TIP.)
CURB TO MATCH EXISTING
HANDICAP PARKING SIGN LOCATED 8" FROM BACK OF
SIDEWALK WHEN IN LAWN AREAS. PROVIDE SIGN WITH
BOLLARD WHEN PLACED WITHIN PAVED AREAS.
PAINTED WHITE 4" PARKING UN ES
PAINTED WHITE HANDICAP ACCESSIBLE ISLE
PAINTED HANDICAP PARKING SYMBOL
PAINTED WHITE TRAFFIC ARROWS SEE DETAIL
13 GENERAL CONTRACTOR TO PROVIDE 6" MIN., APPROVED
TOPSOIL BETWEEN BUILDING AND SIDEWALK. COORDINATE
W /ARCHITECTURAL DRAWINGS
14 INSTALL HANDRAILS PER ARCHITECTURAL DRAWINGS
15 CURB TURNOUT
0 NOT USED
17 8" CONCRETE CURB SIDEWALK, REFER TO
ARCHITECTURAL DRAWINGS.
18 CONCRETE APRON AROUND STORM DRAINAGE INLET
19 8" CONCRETE CURB
2p PAINTED PARKING ISLAND
21 NEW LIGHT POLE AND BASE. VERIFY EXISTING UTIUTES
AT PROPOSED LOCATIONS_ RELOCATE UTILITIES AS
NEEDED.
22 MATCH EXISTING PAVEMENT
23 ADA ACCESSIBLE RAMP
24 1.5" ASPHALT OVERLAY
25 4'x4' CONCRETE PAD FOR MECHANICAL UNIT W /4' TALL
SHADOW BOX FENCE SCREENING.
26 6" CONCRETE CURB
27 ROLLED CURB
2$ STOP SIGN (TYP.)
29 24" PAINTED WHITE STOP BAR
30 VAN ACCESSIBLE HANDICAP PARKING SIGN
PARKING SUMMARY
EXISTING PARKING SPACES 247
REQUIRED PARKING SPACES 288'
PROPOSED PARKING SPACES:
PARKING SPACES 333
HANDICAP SPACES 8
TOTAL PROPOSED SPACES 341
*THE NUMBER OF REQUIRED PARKING SPACES WAS DETERMINED
BY DIVIDING THE NUMBER CF SEATS IN THE MAIN ASSEMBLY.
(1150) BY 4.
1" 40'
0 20 40 80
O
�•v
O
0
CO 0
892
STM
0
X 894.501
W
GAS
F.F.E.
TC
INV
RCP
CMP
PVC
STR.
M.E.G.
SSD
TOC
GUT
OUL
TBM
WV
LEGEND
EXIST. FIRE HYDRANT
EXIST. WATER METER/VALVE
EXIST. SIGN
EXIST. MONITOR WELL
EXIST. IRON PIN OR PK (SET /FOUND)
EXIST. GAS METER
EXIST. GAS VALVE
EXIST. STORM INLET
EXIST. STORM /SAN./TELE. MANHOLE
EXIST. ELECTRIC METER
EXIST. POWER POLE
EXIST. GUY ANCHOR
EXIST. TELEPHONE PEDESTAL
EXIST. MANHOLE
EXIST. CLEANOUT
EXIST. SANITARY SEWER LINE
EXIST. STORM SEWER UNE
EXIST. CONTOURS
PIPE END SECTION
RIGHT -OF -WAY UNE
PROPOSED SANITARY SEWER UNE
PROPOSED STORM SEWER UNE
PROPOSED o HDPE ROOF DRAIN
PROPOSED PIPE BOLLARD
PROPOSED MANHOLE
PROPOSED CONTOURS
PROPOSED ELEVATION
DRAINAGE FLOW ARROW
WATER UNE
GAS UNE
FINISH FLOOR ELEVATION
TOP OF (MANHOLE INLET) CASTING
INVERT (BOTTOM) ELEVATION OF (MANHOLE/INLET)
REINFORCED CONCRETE PIPE
CORRUGATED METAL PIPE
POLYVINYL CHLORIDE PIPE
STRUCTURE
MATCH EXISTING GRADE
SUB SURFACE DRAINAGE
TOP OF CURB
GUTTER
OVERHEAD UTILITY UNE
OVERHEAD TELEPHONE
TEMPORARY BENCHMARK
WATER VALVE
Call 1 BOO-382 -544
2 WORKING DAYS
BEFORE YOU DIG.
"IT'S THE LAW"
CAUTION I1
THE LOCATIONS OF ALL EXISTING UNDERGROUND UfiLR1ES SHOWN ON
THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE (INCLUDING.
BUT NOT LIMITED TO. MANHIOLES, INLETS, VALVES, AND MARKS MADE
UPON THE GROUND BY OTHER) AND ARE SPECULATIVE IN NATURE
THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE 15 NO ABOVE GROUND EVIDENCE OR FOR WHICH NO
ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 0
SAID EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY THE
CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION
PLEASE CALL "HOLEY MOLEY"
1 -800- 382 -5544
SCHMIDT
ASSOCIATES
Wil-Fra-Mar Building
320 East Vermont Street
Indianapolis, IN 46204 -2126
317 -263 -6226
Fax: 317-263-6224
P roject No
Project Dote
Produced
Revision Date
2003 -032 t W03.0545
04.1 6.2004
REVISIONS PER CARMEL TAC COMMENTS 07 2004
REVISIONS PER OWNER'S COMMENTS 08
These Drawings and Specifications, and all copies thereof are and
shill remain the property and copyright of the Architect. They shall
be used only with respect to this Project and are not to be used on
any other Project or Wok without prior written permission from
the Architect.
t 11 I l ►111/1o1/4
G
NO.
10200392
-v STATE OF
(4, 1444
110. i c3 (A 4-
JAMES K. SHINNEMAN P.E. 10200392
a.•
CL.
C102