HomeMy WebLinkAboutC603 Site DetailsPRESSURE PIPE JOINT RESTRAINT TABLE Length Of Pipe To Be Restrained In Each Direction From Of Bend Based On 150 PSI Test Pressure Degree Of Bend 6' 8' 10' 12' 14' 16' 18' 20' 24' 30' 90 ,Tees Plugs 27' 35' 42' 50' 58' 65' 73' 80' 95' 115' 45° 7' 9' 11' 13' 15' 17' 19' 21' 24' 29' 22-1/2° 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11-1/4° 2' 2' 3' 3' 4' 4' 4' 5' 6' 7' N u7 a) to 0 o Wa ter ti Flex /able Joints Flat Slab To MH Riser ASTM C478 Water Lip #4 @12 EW i w See Not IMO LIN Val 1 MH Frame And Cover Neenah R -1642 Or Equal For Wa ter tigh t Installations Neenah R- 1916 -F Cr Equal 'WA TER' Cast In Cover Adjusting Rings 8' Min, 12' Max, 1/2" Cement Plaster Ar Manhole Diameter Shall Be A M/n /mum Of 4'-0". The Designer Shall Specley An Adequate Dia me ter To Accomoda to The Valve And Voter Main Size, Date: January 1995 Gate Valve Concrete Blocking As Required 1 -0' Min, Cast -In Place Concrete Base CITY OF CARMEL STANDARD DETAILS Scaler Not To Scale TITLE: WATER VALVE MANHOLE Drawn By: Jones Henry Engineers, Inc. Drawing Name: CW7 Restrained Joints Shall Be Mechanical Joint With Retainer Glands, US Pipe TR Flex Joint System, US Pipe Field L OK Gasket System, Or Equal. NOTE' THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED, CITY OF CARMEL STANDARD DETAILS Date: January 1995 Scale: Not To Scale TITLE: JOINT RESTRAINT TABLE Drawn B Jones Henry Drawing Name: CW10 y Engineers, Inc. rn N O 0 O Notes' Hydrant Asse Restrained ength And Fittings As Required Water Main Tee M.J, 6'Va l ve Box 6' Gate Valve 1. At High Points Along Main Water Line Where Indicated On Drawings, Anchoring Tee Shall Be Set At 45° Angle Upwards And Connected To 6' 45° Bend, Main Water Line Shall Be Lowered To Provide Sufficient Cover As Specified, 2. All Joints Shall Be Restrained Except In Run Of Tee, 3, Hydrants Shall Be Set At 500' Max, Horizontal Distance, Or Less As Specified By Fire Department Date: January 1995 Mueller Centurion A -423, Or Equal Painted 'Safety Yellow' kft cs Scale: Not To Scale 1 -0' Min. Bedding Material Conforming To INDOT 903.02, Size No, 8 One 8'x8'x16' Solid Conc. Block Or 6'Mln, Class'B' Concrete Base On Undisturbed Ground, CITY OF CARMEL STANDARD DETAILS TITLE: FIRE HYDRANT ASSEMBLY Drawn By: Jones Sc Henry Engineers, Inc. Drawing Name: CW8 Existing Water M Tapping Sleev Varies Bend As Required Valve Varies Note' All Joints Shall Be Restrained Except In Run Of Tee. PLAN New P/pe Shall Be Installed Under The Existing Water Main 4 New Water Main Tee Date: January 1995 12' Mln. vvvvvvvvvvv s vvvvvvvvvvv vvvvvvvvvvv vvvvvvvvvv vvvvvvvvvvv vvvv vvv vvvv vvv vvv vvv vvv vvvv vvvvv••vvvv vv•• CITY OF CARMEL STANDARD DETAILS Scale: Not To Scale SECTION See Trench De to ll For Backf/ll Requirements TITLE: i Existing Voter Main New Water Main Bed P/pe In Specified Granular Bedding Material Hand Tamped In 6' Layers To Pipe Centerline Bedding Material Shall Conform To INDOT 903.02, Size No. 8 WATER MAIN CONNECTION DETAIL Drawn By Jones Henry Drawing Nome: CW5 Engineers, Inc. WATER MAIN NOTES' 1) ALL WATER MAINS SHALL BE DUCTILE CAST IRON PRESSURE PIPE 2) PIPE SHALL CONFORM TO ANSI A-21,51 OR A W WA C -151 AND AT A MINIMUM SHALL BE PRESSURE CLASS 350, 3) FITTINGS FOR DUCTILE CAST IRON PRESSURE PIPE SHALL BE DUCTILE CAST IRON AND CONFORM TO ANSI A -21.10 OR A WA C -110 AND SHALL HAVE A THICKNESS CLASS OF 53, 4) FITTINGS FOR 4-INCH TO 12 -INCH MAY CONFORM TO ANSI A-21,3 OR A W WA C -153. HOLEY MOLEY SAYS, "DON'T DIG BLIND" 1-800 382-5544 CALL TOLL FREE 1-800-428 -5200 FOR CALLS OUTSDE OF INDIANA CM Engineer: k°1 08 0 280 East 96th Street Suite 200 Indianapolis, IN 46240 317.848.7800 (voice) 317.574.0957 (fax) Architect: 8132 Hunters Place Indianapolis, Indiana 46236 317.823.6653 (voice) 317.826.8584 (tax) ®Copyright 2002 Developer: Pedcor Investments, LLC 8888 Keystone Crossing, Suite 900 Indianapolis, Indiana 46240 317.587.0320 Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical, and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractor's shall furnish all items required for the proper execution and completion of the work. Project Carmel City Center Parcel 2B Phase 2 3rd Avenue Southwest Carmel, Indiana Drawing Title: SITE DETAILS Issue Date 01/26/04 Drawn By KRS Checked By RO Certified By Drawing Number: C603 Project Number: 23465