Loading...
HomeMy WebLinkAboutC202 Future Site Development Plan1848.01 IM.E.1 870 <000 LEGEND EXISTING EDGE OF WOODS EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER PROPOSED GRADE MATCH EXISTING PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED SWALE HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) LOT NUMBER PAD ELEVATION PAD SIZE: 60'X60' PROPOSED 5' SIDEWALK (BY 100 874.1 PROPOSED 6" UNDERDRAINS DENOTES 4" SUBSURFACE DRAIN TO LOT DENOTES 6" SUBSURFACE DRAIN ROLL CURB D.U. &S.S.E. D.U. &S.E. D. &U.E. L.M.A.E. S.L.E. D.E. B.S.L. N.R. N.A.E. P.A.E. T.P.E. R/W C.A. EL.EV. 919.28 ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. DRAINAGE, UTILITY SANITARY SEWER EASEMENT DRAINAGE UTILITY SEWER EASEMENT DRAINAGE UTILITY EASEMENT LANDSCAPE, MAINTENANCE ACCESS EASEMENT SIGN LANDSCAPE EASEMENT DRAINAGE EASEMENT BUILDING SETBACK LINE NON RADIAL NON ACCESS EASEMENT PUBLIC ACCESS EASEMENT TREE PRESERVATION EASEMENT RIGHT OF WAY COMMON AREA BENCHMARKS S &A TBM #1 1.0'± UP FROM GROUND ON EAST SIDE ELECTRIC POLE. PWP #74 -693 10TH POLE FROM TOWNE ROAD ON S. SIDE OF 146TH STREET. NOTE TO CONTRACTOR: CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. EXISTING POND .TEMPORARY.. EASEMENT NOTE: CONTRACTOR TO FILL IN EXISTING POND BEYOND PROPERTY LINE. 20' 10.0 0 0 CO 3 cn o a 0 0 0 O (0 X- 0 x X N x co 0 1923.11 56 924.0 1924.01 57 924:0 58 922 ..5 1922.5] 59 920.9 1920.91 1920.41 1919. 61 919.9 1919.71 62 919.7 1919.61 63 919.6 1919.0 64 919.0 1918.41 65 918.4 60 920.4 c0 ---H P 919.5 X N 0 0 O co c0 N 22.81 921.3 54 922:8 53 921.3 x 920.6 52 920.6 1920.11 51 920.1 1919.61 919.8 50 919.8 49 919.8 19 48 919.2 918.8 a, O 03 x x x x X C0 X c0 CO x x X x a) w x x x x U1 POND #2 N.P.= 913.00 10 YR. ELEV.= 914.71 100 YR. ELEV.= 915.81 BOTTOM ELEV. =904.0 917 916 9T5- 914'. 918.5 MEM ao x x x x x X c0 Tip 4, 4 0 0 25 91 8.9 918.9 26 918.9 1918.91 27 919.4 28 919.9 1919.91 (919.41 0 0 0 0) 1916.01 co 18 918.9 x 918.41 17 918.9 1918.91 16 919.4 1919.41 15 919.9 1919.91 00 4 X X x x x co J "HOLEY MOLEY" SAYS: 1 800 -882 -5544 CALL TOLL FREE 1 -800- 428 -5200 FOR CALLS OUTSIDE OF INDIANA SCALE: 1"= 60' CAUTION -o= TE Q' LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. o 0 r m LL LIJ v W 0 J II w w 0 SHEET NO. JOB No.47175S1 m w 0 0 I) z a 0 z 0 z C202