HomeMy WebLinkAboutC104 Utility PlanDATE:
10/30/03
PROJECT NO.:
1238.030
DRAWN BY:
SGE
CHECKED BY:
MJD
SHEET TITLE:
UTILITY
PLAN
DRAWING FILE
N: \1238 \030 \DWGS \C104.DWG
XREF: 026 —B`,. DWG
XREF: 012BS.DWG
XREF: MID— K.DWG
XREF: 3001 ABS.DWG
SHEET NO.:
CZC
EAS
=M INT (ExisTik
5' DRA \AGE, �,TIL 1`Y 8c SEWER
G DER PLAT
U)
s
AVTiR`i VA\-OL
T1 8949O±
1\V. IV= 885,37
\V. CU 885.27
8LF of 8"PVC
(CAP 'SEA_ -,G
\V 89
co
T
F
L LJ
Q
W
5
1_1 3 H0
ILOCAT
E
�T
ERO
L
F
o
T
E LI
CTRL FRO
SIRVC
N
L
V
BROCCOLI BILLS LI\
F.F. ELEV.= 898.50
S
T
=T LC
IC1R CAL
Q
T
BEEHIVE
TC= 894.36
\V 18" RCP \W=888.36
\V 24" RCP SE= 887.21
RELOCATED
SPRINKLER LINE
0
T
PROVD
CO\CR
CRADDL
T
E
EX
LOCAT
ECIRC
ORSEFERRY ROAD
ST
3
L
DR
=T
26' (APHARE
VE
L GI-
T) R/W
15.55'
SA\ TAR Y v AN H OLE
TC= 89L.81
I \V 8" PVC 878.36
I\ V 8" PVC 5= 878.26
I \V 8" PVC \`W= 884.90
Lai
fi
CO
24- RCP
SA \ITARY vIA \HOLE
TC= 895.06
\V 8" PVC 878.06
I V 8" PVC SE= 877.86
CURB I \LET
TC= 894.03
\V 24" RCP \W= 886.68
\V 24 RCP 5E= 886.68
ASSUMED NORTH
SCALE: 1"=10'
ZCTll°SI.,II'IC'SY 7 s
1. IT SHALL BE THE RESPONSIBILITY OF EACH
CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS
PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE
CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE
VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY
BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN
WRITING THE OWNER AND THE ENGINEER OF ANY CHANGES,
OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD
BEFORE WORK IS STARTED OR RESUMED.
2. STANDARD SPECIFICATIONS FOR THE CITY OF CARMEL SHALL
APPLY FOR ALL SANITARY SEWERS, WATER LINES AND STORM SEWERS.
3. ANY PART OF THE UTILITY LINE TRENCHES RUNNING UNDER PAVED
AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL.
4. THE SIZE AND LOCATION OF EXISTING UTILITIES SHOWN ARE PER
INFORMATION PROVIDED BY THE RESPECTIVE UTILITY COMPANIES. ALL
UTILITY COMPANIES SHOULD BE NOTIFIED PRIOR TO ANY EXCAVATION
FOR HELD LOCATION OF SERVICES.
5. WATER SERVICE LINE TO THE BUILDING SHALL HAVE A SHUTOFF
VALVE IN AN ACCESSIBLE LOCATION OUTSIDE OF THE BUILDING.
6. CONTRACTOR TO CONTACT INDIANA GAS COMPANY FOR GAS
CONNECTION TO MAIN. MAIN CONNECTION LOCATION IS TO BE
COORDINATED WITH GAS COMPANY ((317) 776 5533).
7. WATER METER PIT LOCATION TO BE DETERMINED BY CARMEL
WATER COMPANY. COORDINATE WITH PLUMBING PLANS.
8. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN
COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER
SAFETY.
9. WATER SERVICE LINE SHALL BE DUCTILE IRON PER CARMEL
UTILITY REQUIREMENTS.
10. DOWNSPOUTS TO BE CONNECTED TO PVC PIPE PER PLANS.
PROVIDE 1% SLOPE MINIMUM.
GAS
Indiana Gas Company
15900 Allisonville Road
P.O. Box 1700
Noblesville, IN 46060
(317) 776 -5533
TELEPHONE
Ameritech
5858 North College Avenue
Indianapolis, IN 46220
(317) 252 -4275
PRIVATE
Carmel City Utilities
I Civic Square
Carmel, IN 46032
(317) 571 -2442
UTILITIES CARMEL
ELECTRIC
Cinergy
1441 South Guilford
P.O. Box 876
Carmel, IN 46032
(317) 581 -3040
CABLE TV
STORM SEWER SANITARY SEWER
WATER STREETS
Jones Intercable
516 East Carmel Drive
P.O. Box 668
Carmel, IN 46032
(317) 848 -4726
Carmel City Utilities
1 Civic Square
Carmel, IN 46032
(317) 571 -2442
PRIVATE
Utility Hotline: within Indiana 1 -800- 382 -5544
outside indiana 1- 800 428 -5200
c
w
HOLEY MOLEY SAYS
ee DON'T
DIG
BLIND"
"IT'S THE LAW"
CALL 2 WORKING DAYS BEFORE YOU DIG
1 -800- 382 -5544
CALL TOLL FREE
PER INDIANA STATE LAW IS -69 -1991.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
T
N
E
1
NOTE
The size and location of utilities are per plans and locations provided by the
respective utility companies. All utility companies shall be notified prior to any
excavation for field location of services.
II..IE.CrIENIE1
Existing Storm Sewer
Existing Sanitary Sewer
New Sanitary Sewer
(Laterals are shown for reference only)
Sanitary Sewer clean —out
New Storm Sewer
Utility Drainage Esmt.
Building Setback Line
Existing Fire Hydrant
Existing Water Valve
New Water Valve
w— New Water Main
Existing Water Main
New Gas Main
Existing Gas Main
New Electric Line
Existing Overhead Line
New Telephone Line
Existing Telephone Line
Existing Utility Pole
Existing Trees
Sub Surface Drain
New Street Light Electric Line
Existing Street Light Electric Line
NOTE:
CONTRACTOR SHALL NOTIFY CLAY TOWNSHIP REGIONAL WASTE
DISTRICT PRIOR TO CONSTRUCTION OF ALL LATERAL CONNECTIONS
AND EXTENSIONS FROM THE SANITARY SEWER MAIN TO CLEANOUT.
FURTHERMORE, C.T.R.W.D. SHALL BE NOTIFIED PRIOR TO ANY
LATERAL CONNECTIONS TO BUILDINGS. C.T.R.W.D.: (317)844 -9200
CANDY FELTNER.
,DHN0
eL
--g,,,* No.10100357
j STATE F 4c
1/4 ANP �C��
►f Il1rr\\\
DA TL' 10 /30/03
THIS DRAW NG AND THE IDEAS, DESIGNS AND
CONCEPTS C' NTAINED HEREIN ARE THE EXCLUSIVE
INTELLECT' HAL PROPERTY OF THE SCHNEIDER
CORPORATi )N, AND ARE NOT TO BE USED OR
REPRODUCE i, IN WHOLE OR IN PART, WITHOUT
THE WRIT IN CONSENT OF THE SCHNEIDER
CORPORATION.
0 COPYRIi.HTED BY THE SCHNEIDER CORP. (20016
Schneider
THE SCHNEIDER CORPORATION
Historic Fort Harrison
8901 Otis Avenue
Indianapolis, IN 46216 -1037
Telephone: 317.826.7100
Fax: 317.826.7200
www.schneidercorp.com
Arch itecture
Civil Engineering
Environmental Engineering
Geotechnical Services
GIS *[.I3
Home Builder Services
Interior Design
Land Surveying
Landscape Architecture
Transportation Engineering
C4-- -I