HomeMy WebLinkAboutC102 Grading, Drainage & Utility PlanDATE: 11/06/01 PROJECT NO.: 1238.020 DRAWN BY: DCC CHECKED BY: SHEET TITLE: GRADING, DRAINAGE UTILITY PLAN DRAWING FILES: N:\1238\020\DWGS\C102.DWG XREF: 020-BS.DWG XREF: 012BS.DWG XREF: MID-BS.DWG XREF: 3001 ABS.DWG SHEET NO.: C 1 02 02 kt CD Gui ,.s.,. 0 C 1. 0 i t!„, NCI' VILLAGE OF .,,WESTCL IY THE VILL et!" 898.12 896.05 12' OF 12* RCP 0 2.20% 896.3 TC 895.88 GUT TCGfj 896.05 GUT 896.55 896.14 897.04 896.54 896.25 897.15 898.10 TC 897.60 GUT 1898.001 TC 897.50 GUT TC To 1897.921 KTION 3001-} A GE I lLEN_TERT AR TI 2, 11398.28 TC 897.78 GUI 1897.561TC (N7T06 GUT Te Tc 18 12= R 0 0.60% (95.66)GU,T EX. IC f EX, TC=896.22 I r T 1897.20ITC (8 a_ 1 1 1 896.37 571 OF lr RCP 0 1.20% TC 895.88)GUT 1896.181 CUT 30, RCP EXISTING VILLAGE OF WESTCLAY SECTION 3001-C 7 t [02,STC 897.33 GUT R UT SANIT EX. ,IC=896.40, BE RDAOVED ARY UNE EX. TC=897.96 T° E 1897.46ITC (0 ,1 ...i i 7 y --e, yr UlSTING BUILDING E. 30" RCP TTSBJRY STR IET 1897.331TC Cirg. 4 4 4 4 1 EX TC=897.87 EX: EX. 121 RCP I I, I t_X TC=897.90 C:2 C. 1 t 1 ..4..,•... ,-...-:.F",i,,-...-1„,:...z...„:,,,......-„,.-,:.-.;•-;15;;I:11:;.,::::;•.:..,,'„.:;,"';;:‘,;- ":::;,..1.,--i,:i1,.„,...„-.7:"..:2::;7_7:::7.--...... -,„:„?„,-J,;-:,::::--- 1/1/7 i I 1 'Il EX. 30" RCP EX.112" RCP I LJJ uJ EX. t3" PVC k 'I I O., 1 1 ••■111MIMIINI4INNAMMNI•MN 000 x ELEV DESC (000.00) faro.ifdl- Existing Storm Sewer New Storm Sewer Existing Sanitary Sewer New Sanitary Sewer Existing Contour Existing Elevation w/ description New Pavement Grade All Other Finish Grades Storm Structure Number Sanitary Structure Number Clean Out Flow Arrow 6" Subsurface Drain Swale (0 Burried Electric Burried Telephone Burried Gas Line SANITARY SEWER DATA EX. SANITARY STRUCUTRE 469 EX. TC=896.40 EX. INV. IN-886.26 (8" PVC SW) EX. INV. IN-886.26 (8" PVC N) (TO BE REMOVED) NEW INV. IN-886.26 (8" PVC NW) EX. INV. OUT-886.16 (8" PVC E) SANITARY STRUCUTRE 401 TC=896.33 INV. IN-886.38 (8" PVC SE) INV. OUT-886.48 (8" PVC N) STORM SEWER DATA EX. STORM STRUCUTRE 102 TC=895.60 INV. IN-891.16 (18" RCP NW) (EX. 10' STUB) INV. IN-892.35 (12" RCP W) (EX. 10' STUB) INV. OUT-890.91 (21" RCP S) STORM STRUCUTRE 109 TC=895.96 INV. OUT-892.46 (12" RCP E) STORM STRUCUTRE 103 TC=896.33 INV. IN-892.66 (12" RCP NW) INV. IN-891.84 (12" RCP N) (68' STUB) INV. OUT-891.84 (18" RCP SE) STORM STRUCUTRE 110 TC=896.55 INV. IN-892.93 (12" RCP NW) INV. OUT-892.93 (12" RCP SE) STORM STRUCUTRE 111 TC=898.12 INV. IN-894.60 (12" RCP NW) (10' STUB) INV. OUT-894.60 (12" RCP SE) ASSUMED NOR [H SCALE: 1"=20' HOLEY MoLEY SAYS DON'T DIG BLIND' "IT'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1-800-382-5544 CALL TOLL FREE PER INDIANA STATE LAW IS-69-1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. -1ENIERAIL INCYTIES ALL GRADES AT BOUNDARY SHALL MEET EXISTING GRADES. 2. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATIONS FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 3. STANDARD SPECIFICATIONS FOR THE HAMILTON COUNTY SURVEYOR SHALL APPLY FOR ALL STORM SEWERS. 4. STANDARD SPECIFICATIONS FOR CLAY TOWNSHIP REGIONAL WASTE DISTRICT APPLY FOR ALL SANITARY SEWERS. 5. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 6. THE SIZE AND LOCATION OF EXISTING UTILITIES SHOWN ARE PER INFORMATION PROVIDED BY THE RESPECTIVE UTILITY COMPANIES. ALL UTILITY COMPANIES SHOULD BE NOTIFIED PRIOR TO ANY EXCAVATION FOR FIELD LOCATION OF SEI 7. SERVICE. WALKS SHALL BE NON-REINFORCED CONCRETE 4" THICK AND 4' IN WIDTH. 8. EXPANSION JOINTS ARE TO BE PLACED AT ALL WALK IN IFIRSECTIONS AND BETWEEN WALKS AND PLATFORMS. SITEWALK SCORES ARE TO BE EQUALLY SPACED BETWEEN EXPANSION JOINTS, CONTRACTION JOINTS AND PERPENDICULAR TO SIDEWALKS AT 5' INTERVALS OR LESS WITH A CONTRACTION JOINT EVERY 20' OR LESS. 9. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 11 ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 11. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES. 2. REMOVE AND BACKFILL ALL AREAS WHERE ANY FIELD TILE CROSSES PROPOSED HOUSE PADS. ALL FIELD TILES INTERCEPTED TO BE PERPETUATED INTO STORM SEWER SYSTEM OR LAKE. THE SUBCONTRACTOR SHALL NOTIFY IN WRITING THE OWNER AND THE ENGINEER IN ANY CIRCUMSTANCES WHERE THIS CANNOT BE ACCOMPLISHED. 3, ALL FILL AREAS SHALL BE COMPACTED TO AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D-1557). FILL UNDER THE FOOTING SHALL BE COMPACTED TO AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D-1557). TRENICIREIMIAIRIK IBM #44 USGS BENCHMARK CUT "X" NORTH BONNET BOLT IN FIRE HYDRANT EAST SIDE HOOVER RD. ±100' SOUTH OF CLARIDGE FARM ENTRANCE. ELEVATION 893.39 -0 9800085 IS; STATE OF e Y DI AN vS/ ONAL #0 //mitilltutIttO DATE: THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. 0 COPYRIGHTED BY THE SCFINEIDER CORP. (2001) THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering CY)