Loading...
HomeMy WebLinkAbout10 EMP Plan1 North 0 10 20 IN FEET 1 inch 10 ft. TC=752110 INV= 747.72 GRAPHIC SCALE 79' 12" HDPE 0.50% SLLIPE 704 TC=752121 INV =748.9 14' 15" 7 ES INV 746 PE 7 750 749 744 745 15' 18" HDPE 0.33% SLDPE 11' 18" HDPE 0.36% SLDPE 40 PsPA1 7-50 Bottom 748.85 74C,00 747 707 TC=752158 INV= 747.76 5' 15" I-DPE 0.04% SLDPE =lei AQUA SWIRL SPECIFICATION NOTES 1. Manufacturer shall be responsible for complete assembly of Swirl Concentrator. 2. Swirl Concentrator shall be fabricated from Solid Wall high density polyethylene (HDPE) ASTM F 714 cell class 345464C per ASTM D 3350 or walls greater than 63" OD shall be fabricated from profile wall HDPE ASTM F 894 RSC 250. 3. HDPE stub outs and internal components shall be extrusion welded using accepted welding practices. Stub outs shall be supplied by Manufacturer and welded on inside and outside. 4. Manufacturer shall supply direct access to Swirl Concentrator via 30 -inch ID riser(s), which can be field cut to match finished grade by Contractor. 5. Contractor shall supply pipe couplings to and from Swirl Concentrator, which shall be Fernco or Mission style neoprene boot with stainless steel tension bands and shear guard. 6. Contractor shall prepare excavation and off -load Swirl Concentrator. Contractor is responsible for bedding and backfill around Swirl Concentrator as detailed on site plan. (see notes 10 and 11) 7. Manufacturer shall supply standard manhole frame(s) and cover(s). (Traffic rated 1120) 03 -20 -03 8. Where traffic loading (H -20) is required or anticipated, a reinforced concrete pad must be placed over the entire Swirl Concentrator per concrete design as calculated by Engineer. Sample of typical concrete design detail is available upon request. 9. Bollards shall be placed around access risers in non traffic areas to prevent inadvertent loading by maintenance vehicles. Sample of typical bollard installation detail and recommended locations of bollards around the Swirl Concentrator can be provided upon request. 10. Excavation and Bedding The trench and trench bottom shall be constructed in accordance with ASTM D -2321, Section 6, Trench Excavation, and Section 7, Installation. The HDPE Swirl Concentrator shall be installed on a stable base consisting of 12- inches of Class I stone materials (angular, crushed stone or rock, crushed gravel; large void content, contains little or no fines) as defined by ASTM D2321, Section 5, Materials, and compacted to 95% proctor density. All required safety precautions for Swirl Concentrator installation are the responsibility of the Contractor. 11. Backfill Requirements Backfill materials shall be Class I or II stone materials, (well graded gravels, gravely sands; contains little or no fines) as defined by ASTM D2321, Section 5, Materials, and compacted to 90% proctor density. Class I materials are preferred. Backfill and bedding materials shall be free of debris. Backfilling shall conform to ASTM 1759, Section 4.2, "Design Assumptions Backfill shall extend at least 2 feet outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser(s)) extending laterally to undisturbed soils. 1. System shall be designed for the following capacities: Peak Treatment Flow: 3.2 cfs Sediment Storage: 32 ft Oil/Debris Storage: 190 gal. Please see accompanied Aqua -Swirl specification notes. See Site Plan for actual system orientation. Manhole Frame Cover Detail For H -20 Traffic Loading Areas NTS Pipe coupling by Contractor. 12" long Stub -out by Manufacturer. Section A -A Aqua -Swirl Concentrator Model AS -4 Standard Detail Rim elevations to match finished grade. HDPE risers can be field cut by Contractor. STANDARD NOTE: 1. System shall be designed for the following capacities: Peak Treatment Row: 1.8 cfs Sediment Storage: 20 ft Oil /Debris Storage: 110 gal. Please see accompanied Aqua -Swirl spedfication notes. See Site Plan for actual system orientation. 54" AquiShieldir STOW TREATMENT •OLUTION• 2733 Ka tona Drh C, Suite A, Chattanooga, TN 37344 Phone (888) 3449044 Fax (423) 870 -1005 www.aouashieldh c.o m Octagonal Base Plate 54" Plan View DoCUment: Drawn By: Scale: Date: AS-3 STD 1:20 66" 02/24/04 us. Pantent No. 6524473 and other Patent Pending! Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Vent Arched Baffles Manhole Frame Cover Detail For H -20 Traffic Loading Areas NTS Varies 16" OD Max Manhole Frame and Cover by Manufacturer. (See Detail) 104" Section A -A Aqua -Swirl Concentrator Model AS -3 Standard Detail Rim elevations to match finished grade. HDPE risers can be field cut by Contractor. Vent Varies olltili?11i 11/ k. S K4 No.r.• 880 5 73 .o•'•. ST OF S O N A L ttlii llll l BMP STRUCTURE 706A BMP STRLJCTURE 703A falcon ENGINEERING, INC. 13110 Promise Road, Noblesville, IN 46060 Phone: (317) 841 -3141 Fax: (317) 841 -9951 Date March 29, 2004 Job No. Scale 100.0 1' =30' Sheet No. 10 OF 10