Loading...
HomeMy WebLinkAboutC3 Grading & Drainage PlanASPHALT LIGHT (TYP.) 25' INGRESS /EGRESS UTILITY EASEMENT (SCALES 30' ON PLAT REPLACE EXISTING CASTING WITH NEENAH R -3405 EX. TC= 738.96 Co NEW TC.= 738.81 R RAISED CURB I- J +ND 24" RCP INV 733.10 12" RCP INV 732.85 24" RCP INV. 732.67 12" RCP INV 732.88 EDGE OF CONCRETE STORM MH TC 739.86 311V 73L.86� 27" REF:, 742.71 742.21 96TH STREET 18" RCP INV 732.76 C.E.S. #1 740.39 740.14 740.79 742.00 742.90' 742.7 742.64 EENA .C. =7 UT. 743.1 43.30 43.14 741.08 R- 0.60 40.10 742.52 742.02 743.44 742.94 743.30 743.30 743.48 742.98 742.80 743.40 743.50 743.50 742.98 743.50 743.50 743.50 743.50 43.0 743.40 742.88 an _E 743.48 B I 743.38 743.30 743. 742.88 742.80 743.30 i 742. euRErmir Q.' F42.80 743.6 -328 .C. =7 T. =7 V. -7 743,15 -8V 9.90 9:40 6.8 740.88 740.3 741.63 742.38 738.84 742.68 740.18 INV 733.00 732 733 --734 .735 736 737 738 x 742.88 20' SEWER ESMT. PER D.B. 232, P. 97 7 3 7 734 ___ho_ o� EDGE OF CONCRETE CONCRETE PAVEMENT E(A) E( 15' D. U. E. 18" RCP INV 732.63 ttttt>.t>A�ttttttttttt� ��11r�� ®wRea ®I vIJ x ^0.; BEEHIVE'11�ilrET TC 737.20 732.10 NON- -ACESS'.:EASEMENT 63' ELEC. LINE ESMT. PER D.B. 235, P. 144 INST. #1441 OVERHEAD ELECTRIC E(A) 444 8684 X96 (856 L V. 738,E 24" WiTER LINE ER IWC /GIF MAPPING UNDERG OUND t• TELEPHONE CABLE 170.1344. ELEV. 740.73 5O A'. P HALT C) SE CORNER LOT 2 SE CORNER SE 1/4 SEC. 5, T17N, R4E HARRISON MON FOUND N.1704404.3020 E- 209602 6085® ELEV. =736 .2 FLOODPLAIN NOTE: ALL BUILDINGS WITHIN THE FLOODPLAIN MUST HAVE FINISHED FLOOR ELEVATIONS (INCLUDING BASEMENTS) A MINIMUM OF TWO (2) FEET ABOVE THE BASE FLOOD ELEVATION. THE FILL FOR THE BUILDING PADS MUST BE COMPACTED TO A MINIMUM OF 95% OF MAXIMUM DENSITY USING THE STANDARD PROCTOR TEST METHOD. THE COMPACTION TESTS SHALL BE PREFORMED AND CERTIFIED BY QUALIFIED TESTING AGENCY AT THE COST OF THE DEVELOPER. THE SURFACE OF THE FILL MUST EXTEND AT LEAST TEN (10') HORIZONTALLY FROM THE PERIMETER OF THE BUILDING BEFORE SLOPING BELOW THE BASE FLOOD ELEVATION. THIS IS A MINIMUM DISTANCE WHICH MAY NEED TO BE EXTENDED BASED ON SITE CONDITIONS. BASE FLOOD ELEVATION: 100 YR. CARMEL CREEK VARIES FROM 740.00 TO 740.50. PER FLOOD INSURANCE STUDY, HAMILTON CO., IN., FEBRUARY 19, 2003 FIRM MAP NO. 18057CO237 F 6" STANDING CURB 3 -0" TAPER AMSWA/..../%:V./ TBM CUT BOX ON CURB ELEV 739.33 SECTION VIEW 5' -0" END OF CURB PLAN VIEW CURB CUT TAPER DETAIL TAPER 892 0 894.50 W GAS F.F.E. TC INV RCP CMP PVC STR. M.E.G. SSD TOC GUT OUL T TBM WV SITE BENCHMARK SITE BENCHMARK (NO SCALE) 6" STANDING CURB 6" STANDING CURB LEGEND UNITED SURVEYING REBAR w /CAP MARKED UCP #21. ELEV 737.06 "NUM.,...\\\\I■ EXIST. FIRE HYDRANT EXIST. WATER METER /VALVE EXIST. SIGN EXIST. MONITOR WELL EXIST. IRON PIN OR PK (SET /FOUND) EXIST. GAS MEIER EXIST. GAS VALVE EXIST. STORM INLET EXIST. STORM/SAN./TELE. MANHOLE EXIST. ELECTRIC METER EXIST. POWER POLE EXIST. GUY ANCHOR EXIST. TELEPHONE PEDESTAL EXIST. MANHOLE EXIST. CLEANOUT EXIST. SANITARY SEWER LINE EXIST. STORM SEWER LINE EXIST. CONTOURS PIPE END SECTION RIGHT -OF -WAY LINE PROPOSED SANITARY SEWER LINE PROPOSED STORM SEWER LINE PROPOSED 6" HDPE ROOF DRAIN PROPOSED PIPE BOLLARD PROPOSED MANHOLE PROPOSED CONTOURS PROPOSED ELEVATION DRAINAGE FLOW ARROW WATER LINE GAS LINE FINISH FLOOR ELEVATION TOP OF (MANHOLE INLET) CASTING INVERT (BOTTOM) ELEVATION OF (MANHOLE /INLET) REINFORCED CONCRETE PIPE CORRUGATED METAL PIPE POLYVINYL CHLORIDE PIPE STRUCTURE MATCH EXISTING GRADE SUB SURFACE DRAINAGE TOP OF CURB GUTTER OVERHEAD UTILITY LINE OVERHEAD TELEPHONE TEMPORARY BENCHMARK WATER VALVE GENERAL NOTES: 1) CONTRACTOR SHALL VERIFY SITE SOIL BALANCE REQUIREMENTS. EXCESS /DEFICIENT MATERIAL QUANTITIES SHALL BE FIELD ADJUSTED. ADJUSTMENTS IN FINAL GRADES AS SHOWN SHALL BE FIELD ENGINEERED AS REQUIRED, AND AS APPROVED BY STEAK 'N SHAKE AND THE ENGINEER. GRADING INTENT AS SHOWN SHALL BE MAINTAINED. EXCESS SOIL SHALL BE REMOVED FROM THE SITE. Call 1- -800 382 --5544 2 WORKING DAYS BEFORE YOU DIG. "IT'S THE LAW" CAUTION!! THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE (INCLUDING. BU r NOT LIMITED TO, MANHOLES, INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY OTHER) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 0 SAID EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION PLEASE CALL "HOLEY MOLEY" 1 -800- 382 -5544 SHEET NO. o o1l1I Ii 1 !l111 14/ K S NIv Nr CG1STL- 4 9 `t` R NO. 10200392 STATE OF 4,. -.3 /41D1A G ES K. SHINNEMAN P.F:. 10200392 10 [)R -.WING. 1H: \2004 \VW04C266 \ENG \t gnset 040256003 -dwg LAYOUT (rad; H I. (1.3 a-flR 9 9 8 8 7 6 6 5 5 4 4 3 3 2 2 1