Loading...
HomeMy WebLinkAboutA501 Retaining Wall & Outdoor Stair PlansG2 2 SCALE: 1/4 =1' -0" 1 A2 SCALE: 1/4 =1' -0" 1 2 NEW OUTDOOR STAIR 3 EXISTING OUTDOOR STAIR 3 4 4 5 6 5 6 7 7 8 8 A9 9 10 CO\S SEQUE\CEI VERIFY LOCATION OF EXISTING STRUCTURES AND UTIUTIES. •EXCAVATE AREA LARGE ENOUGH TO ACCOMMODATE LEVEUNG PAD, REQUIRED UNIT EMBEDMENT, AND REQUIRED GEOGRID LENGTHS. PROOF ROLL AND COMPACT EXCAVATED FOUNDATION AREA. i EXISTING GRADE rIN APPROXIMATE EXCAVATION UNE, FOLLOW OSHA f GUIDELINES GRANULAR LEVELING PAD MIN. 6" THICK BY 24" WIDE STEP 1 1 1 i UNDISTURBED SOIL PLACE LOWEST COURSE OF WALL UNITS ON LEVEUNG PAD, SETTING UNIT SIDES AGAINST ADJACENT UNITS. LEVEL UNITS SIDE -TO -SIDE, FRONT -TO -REAR, AND WITH ADJACENT UNITS. •CHECK ALIGNMENT ALONG BACK OF UNITS. •PLACE AND COMPACT BACKFILL IN FRONT AND BEHIND UNITS TO BE EMBEDDED BELOW FINAL GRADE. i i COMPACTED BACKFILL EMBEDMENT VARIES, APPROX tuIATELY 1/10 THE WALL HEIGHT FIRST COURSE STEP 2 PLACE NEXT COURSE OF UNITS. INSERT TWO CONNECTION PINS THROUGH TWO OF THE FOUR CENTER HOLES OF THE UPPER COURSE UNITS INTO THE CENTER SLOTS OF THE LOWER COURSE UNITS. CHECK LEVEL AND ALIGNMENT OF UNITS. CONTINUE PLACING COURSES OF UNITS AND COMPACTING BACKFILL IN FRONT OF AND BEHIND UNITS UNTIL REACHING HEIGHT OF FINAL GRADE IN FRONT OF WALL BEGINNING JUST ABOVE THE FINAL GRADE IN FRONT OF WALL, PLACE DRAINAGE AGGREGATE BEHIND THE UNITS TO REQUIRED THICKNESS. INSTALL DRAINAGE COLLECTION PIPES AT BASE OF DRAINAGE AGGREGATE, WITH PERFORATION OR SLOTS FACING DOWN. SLOPE DRAIN PIPE TO ALLOW GRAVITY FLOW OF WATER TO OUTSIDE THE WALL SYSTEM, OUTLETTING PIPES AS REQUIRED. PLACE AND COMPACT REINFORCED BACKFILL BEHIND DRAINAGE AGGREGATE. FINAL GRADE HI DRAIN AGGREGATE 1 THICK MIN. DIA. DRAIN WIPE OUTLET AT END OF WALL OR AT 40' CENTERS MAX. STEP 3 N J 2 f r REINFORCED BACKFILL COMPACTED 95% OF MAXIMUM STANDARD PROCTOR DENSITY CONTINUE PLACING UNITS, DRAINAGE AGGREGATE AND REINFORCED BACKFILL, UNTIL REACHING HEIGHT OF GEOSYNTHETIC LAYER. LAY THE REQUIRED LENGTH OF GEOSYNTHETIC HORIZONTALLY ON TOP OF THE UNITS, ENSURING HIGHEST STRENGTH DIRECTION OF GEOSYNTHETIC IS PERPENDICULAR TO WALL FACE. PLACE NEXT COURSE OF UNITS ON TOP OF GEOSYNTHETIC AND PIN DOWN THROUGH GEOSYNTHETIC INTO UNITS BELOW. •PLACE DRAINAGE AGGREGATE BEHIND UNITS TO REQUIRED THICKNESS. PULL BACK OF GEOSYNTHETIC TO REMOVE ANY WRINKLES OR LOOSENESS. DO NOT OVER TENSION. USE STAPLES, STAKES, OR HAND TENSION TO KEEP GEOSYNTHETIC TAUT UNTIL BACKFILL IS PLACED ON TOP. i STEP 4 f REINFORCED BACKFILL COMPACTED 95% OF MAXIMUM STANDARD PROCTOR DENSITY PULL GEOSYNTHECTIC TIGHT AND HOLD IN PLACE WITH STAKE OR BY OTHER MEANS GEOSYNTHETIC REINFORCEMENT TYPE, LENGTH AND SPACING VARIES CONTINUE PLACEMENT OF WALL UNITS, GEOSYNTHETIC, DRAINAGE AGGREGATE AND REINFORCED BACKFILL BY REPEATING STEP 4 UNTIL WALL IS WITHIN ONE FOOT OF FINAL HEIGHT. STACK NO MORE THAN THREE COURSES BEFORE BACKFILL IS PLACED BEHIND WALL COMPACT BACKFILL IN NO GREATER THAN 6" THICK UFTS. STEP 5 i REINFORCED BACKFILL COMPACTED 95% OF MAXIMUM STANDARD PROCTOR DENSITY PLACE AND COMPACT IMPERVIOUS SOIL BEHIND THE TOP 12 INCHES OF THE WALL. PLACE AND ALIGN CAP UNITS, WITH A SLIGHT OVERHANG, ON TOP COURSE. AFTER ENSURING PROPER AUGNMENT, REMOVE AND THEN ADHERE CAPS WITH VERSA -LOK ADHESIVE. CAP UNIT ADHERES TO TOP COURSE WITH VERSA -LOK CONCRETE ADHESIVE IMPERVOUS FILL 12" DEEP STEP 6 t SLOPE AND LOADING VARIES REINFORCED BACKFILL COMPACTED 95% OF MAXIMUM STANDARD PROCTOR DENSITY RETAINING WALL CONSTRUCTION SCALE: NONE 9 10 11 11 12 12 13 13 14 14 15 INSTALLATION NOTES 16 1 17 1 18 STRIP VEGETATION AND ORGANIC SOIL FROM WALL AND GEOSYNTHETIC ALIGNMENT. BENCH CUT ALL EXCAVATED SLOPES. DO NOT EXCAVATE BEYOND EXCAVATION LINES SHOWN ON PLAN UNLESS DIRECTED BY SITE SOILS ENGINEER TO REMOVE UNSUITABLE SOIL CONTRACTOR SHALL ENSURE TEMPORARY EXCAVATIONS ARE STABLE AND PROVIDE EXCAVATION SUPPORT IF NEEDED. SITE SOILS ENGINEER SHALL VERIFY FOUNDATION SOILS AS BEING COMPETENT PER THE DESIGN PARAMETERS. LEVELING PAD SHALL CONSIST OF WELL GRADED ROAD BASE AGGREGATE, 3/4" CRUSHED, ANGULAR GRAVEL WITH SOME FINES CONTRACTOR MAY OPT FOR A LEAN CONCRETE LEVELING PAD. PAD SHALL BE UNREINFORCED LEAN CONCRETE, 200 -300 PSI, 3" THICK MAXIMUM. DRAINAGE AGGREGATE SHALL CONSIST OF CLEAN ANGULAR GRAVEL, 3/4" DIAMETER WITH LESS THAN 5% FINES. DRAINAGE PIPE SHALL BE PERFORATED OR SLOTTED PVC OR CORRUGATED HDPE PIPE. REINFORCED BACKFILL SHALL BE FREE OF DEBRIS, ORGANIC SOIL, AND EXPANSIVE SOILS. FOR UNITS TO BE EMBEDDED, COMPACT FILL IN FRONT OF UNITS AT THE SAME TIME FILL BEHIND UNITS IS COMPACTED. COMPACTION SHALL BE TO 95% OF MAXIMUM STANDARD PROCTOR DENSITY. (ASTM D -698) COMPACTION TESTS SHALL BE TAKEN AS THE WALL IS INSTALLED. THE MINIMUM NUMBER OF TESTS SHALL BE DETERMINED BY THE SITE SOILS ENGINEER. COMPACTION WITHIN 3FT. OF WALL SHALL BE LIMITED TO HAND OPERATED EQUIPMENT. CONTRACTOR SHALL SLOPE SITE GRADES TO DIRECT SURFACE RUNOFF AWAY FROM WALL AT END OF EACH DAY TO AVOID WATER DAMAGING THE WALL WHILE UNDER CONSTRUCTION. ANY SURFACE DRAINAGE FEATURES, FINISH GRADING, PAVEMENT, OR TURF SHALL BE INSTALLED IMMEDIATELY AFTER WALL IS COMPLETED. FOLLOW APPLICABLE PROVISIONS OF "IHE WALL UNIT AND GEOSYNTHETIC MANUFACTURER'S INSTALLATION INSTRUCTIONS AND WRITTEN SPECIFICATIONS. IF SITE AND SOIL CONDITIONS, WALL GEOMETRY, OR WALL LOADINGS ARE DIFFERENT THAN IN THE DRAWINGS AND THE DESIGN PARAMETERS, THE CONTRACTOR MUST CONTACT DESIGN ENGINEER PRIOR TO PROCEEDING WTH THE CONSTRUCTION OF THE WALL. DESIGN PARAMETERS AND PROVISIONS THE DESIGN OF THE WALL SYSTEM ASSUMES THE FOLLOWING PARAMETERS: FRICTION UNIT SOIL CONDITIONS ANGLE WEIGHT REINFORCED BACKFILL RETAINED BACKFILL FOUNDATION SOIL 15 HYDROSTATIC LOADING NONE SURCHARGE LOAD AT TOP OF WALL ALLOWABLE BEARING CAPACITY THE WALL DESIGN ENGINEER ASSUMES NO LIABILITY FOR INTERPRETATION OF SUBSURFACE CONDITIONS, SUITABILITY OF SOIL DESIGN PARAMETERS AND INTERPRETATIONS OF SUBSURFACE GROUNDWATER CONDITIONS. THE OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR ENSURING THE CONDITIONS STATED ABOVE ARE ACCURATE PRIOR TO AND DURING CONSTRUCTION. THE OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR ENSURING THE WALL DESIGN ENGINEER IS CONTACTED IF CONDITIONS VARY. IT IS THE OWNER OR THE OWNER'S REPRESENTATIVE'S RESPONSIBILITY TO ENSURE EXTERNAL STABILITY OF THE WALL, INCLUDING BEARING CAPACITY AND SLOPE STABILITY, IS PROPERLY REVIEWED AND EVALUATED BY A QUALIFIED CIVIL ENGINEER. THE WALL DESIGN SHOWN IN THESE DRAWINGS DO NOT ADDRESS THE SUFFICIENCY OF THE BEARING CAPACITY NOR THE SLOPE STABILITY OF THE WALL SYSTEM AND SURROUNDING SOIL 16 17 18 REVISIONS TE REVISIONS/SUBMISSIONS ckK No. 3965 STATE OF NOT PUBUSHED ALL RIGHTS RESERVED THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED IEREIN ARE 1HE EXCLUSIVE PROPERTY OF MAS ASSOCAIATES AND ARE NOT TO BE USED OR REPRODUCED NI WHOLE OR IN PMT, WITHOUT TIT; WRITTEN CONSENT OF MAS ASSOCAIATES. MAS ASSOCIATES, LLC. Architects and Planners 5200 East 64TH Street, Suite A Indianapolis, Indiana 46220 msmith@masassociates.net Phone 317 726 1060 Fax 317 726 1061 Formerly Cool Creek Apartments CARMEL WOODS APARTMENTS Carmel, Indiana DATE PROJECT NO. DRAWN APPROVED MAS I MAS COMPUTER FILE NAMES RETAINING WALL AND OUTDOOR STAIR PLANS 10/30/2003 2341.001 SNIT NO. A501