Loading...
HomeMy WebLinkAbout11 Water Main Extension PlanEx. Hydt. Job No. 1 PVC Pipe Size: 121n 416' Job No. 2 PVC Pipe Size: 6!n 367' New Hydt. Billy Creek Assoc 520 116 ST W 1- 800 382 -5544 CALL BEFORE YOU DIG Project Name Project Number Dist. Map No. Meter Map No. Lots Tax Code Pressure Dist Drafter Date JBM /BANN /NB 3-16-03 Project No: 03146 Sheet No: JOB STREET NO. NAME 1 116TH STREET 2 CHATEAUX DRIVE VEOLIA WATER PROJECT LEGEND PROJECT NAME: CHATEAUX DE MOULIN PROJECT NUMBER: PIPE 12 SIZE 8 6 3 PIPE TYPE TOTAL PVC 416' PVC 670' PVC 367' PE 255' TOTAL 1,708' \03146 \iwc 103146H20.dgn 5/27/74 3: 08: 26 PM 5 4' CONC. WALK WATER MAIN T-0' 4'-0' COMMON AREA 7 -0' 1. THIS SHEET DESIGNED FOR IW PURPOSES ONLY. ALL OTHER INFORMATION SHOWN IS FOR REFERENCE ONLY AND NOT TO BE UTILIZED FOR ANY CONSTRUCTION OTHER THAN THAT OF THE WATER MAIN 3. NO STREET ADDRESS PROVIDED AT TIME OF PLAN 22- O'COMMON AREA 14'-0' 2. THE WATER MAIN EXTENSION SHEETS ARE CONSIDERED PRELIN INARY UNTIL IW HAS THEIR STAMP AND SIGNATURE APPROVING PLAN. ANY QUANTITIES FROM THESE SHEETS COULD BE SUBJECT TO CHANGE AT ANY TIME DURING IW REVIEW 5 ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO CONSTRUCTION, IN THE EVENT OF THE CONTRACTORS'S FAILING TO GIVE SUCH NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. 40' CQiIOq 4. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY EXISTING UTILITY LOCATIONS AND CONDITIONS. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE VARIOUS UTILITIES FOR PROPER STAKING LOCATIONS FOR EACH PRIOR TO CONSTRUCTION. VARIES Conc. roll curb gutter (see detail this sheet) CHATEUX DRIVE ENTRANCE NO SCALE 1 a PROFILE GRADE AREA VARIES b' Sire rfocs drib Cfsicdboth delis of rood) N O T E C H A T E A U OWE T O B E 2a BACK OF CUM TO BACK OF CUR TYPICAL STREET SECTION No wiz r Telephone Pole Po,. Gas Pole 0 Inlet Tree GAS VALVE Parcel Id Adapter INe I/t Bend sj MAIEJY111 Kicker Block 10}1 Cross 22'- O'COMMON AREA 20'-0" NOTE: DETAILS ARE FOR VEOLIA WATER REFERENCE ONLY, STREET CONSTRUCTION SHALL BE INSTALLED IN CONFORMANCE WITH THE HAMILTON COUNTY STANDARDS. Legend 2' -0" GAS UT UE Existing Water Main Proposed Water Main Hydrant Hydrant with Hydrant Valve FLH El Flush Hydrant Q Butterfly Valve Valve la.a Blowoff Assembly w Air Relief Valve r Plug II Reducer tst T.J. Tee M.J. Sleeve Casing Pipe Gas Lines Telephone Lines Electric Lines EX /STING WATER MAIN JOB: New Hydt. OHE Vantassel, Charles J Jr Marjorie 11607 WILLIAMS CREEK N REMOVE PLUG AND 1 1 6TH STREET -KICKER AND RETURN—___________- TO VEOL JAW TER-__ 6 Noland, James E Jr Carolyn K 770 116 ST W P' NON- ACCESS EASEMENT