HomeMy WebLinkAbout06120001 Large Plan for Old Meridian Place, Sec. 1 pg. 21STUB SIZE
HEADER PIPE SIZES
48 42 36
AVAIL AVAIL AVAIL
30 24
18
15 r 12 10
8
24"
AVAIL AVAIL
18"
AVAIL AVAIL AVAIL
AVAIL AVAIL
AVAIL
15
AVAIL AVAIL AVAIL
AVAIL AVAIL
AVAIL AVAIL
1
AVAIL
AVAIL
12"
AVAIL AVAIL' AVAIL
AVAIL AVAIL
AVAIL AVAIL
AVAIL!
AVAIL' AVAIL
AVAILAVAIL'
AVAIL AVAIL
10"
AVAIL
AVAIL AVAIL
AVAIL !AVAIL
AVAIL !AVAIL
8"
AVAIL
6"
AVAIL AVAIL
MATERIAL LOCATION
C
!CATCH BASIN �I
OR
MANHOLE
1 SUMP DEPTH
BY DESIGN
ENGINEER
THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE
THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD
BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOR
EARTH AND LIVE LOADS, WITH CONSIDERATION FOR
IMPACT AND MULTIPLE VEHICLE PRESENCES.
2 INCH CLEAN,
CRUSHED, ANGULAR STONE
ADS 601 GEOTEXTILE OR EQUAL
FOR STORMTECH INFORMATION
CALL 1- 888 -892 -2694
SC -740 CHAMBER
I
11- y "il1
1 P --1 1 I 1 1, 11 I1 1 HI
1 11 -1 1 11j III III III -!II W 11
11
DESIGN ENGINEER IS RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUBGRADE SOILS*
THIS CROSS SECTION DETAILS THE REQUIREMENTS
NECESSARY TO SATISFY THE LOAD FACTORS SPECIFIED IN THE
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12
FOR EARTH AND LIVE LOADS USING STORMTECH CHAMBERS
SC -740 TYPICAL CROSS SECTION
DESCRIPTION
ANY SOIUROCK MATERIALS, NATIVE
TO GRADE ABOVE CHAMBERS SOILS OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT
SUBGRADE REQUIREMENTS.
1
FILL MATERIAL FOR 6" TO 18" GRANULAR WELL GRADED
ELEVATION ABOVE CHAMBERS SOIL/AGGREGATE MIXTURES,
(24" FOR UNPAVED INSTALLATIONS) <35% FINES.
FILL MATERIAL FROM 18"
B EMBEDMENT STONE SURROUNDING
AND TO A 6" ELEVATION ABOVE
CHAMBERS
A FOUNDATION STONE BELOW
CHAMBERS
I
ACCEPTABLE FILL MATERIALS
STORMTECH SC -740 CHAMBER SYSTEMS
CLEAN ANGULAR STONE WITH THE
MAJORITY OF PARTICLES BETWEEN
2 INCH
CLEAN ANGULAR STONE WITH THE
MAJORITY OF PARTICLES BETWEEN
3 2 INCH
MANHOLE WITH
OVERFLOW WEIR
ECCENTRIC
HEADER
PLACE MINIMUM 12.5' OF AASHTO M288
CLASS 1 WOVEN GEOTEXTILE OVER
BEDDING STONE FOR SCOUR PROTECTION
AT ALL CHAMBER INLET ROWS
STORMTECH
PREFABRICATED
END CAPS
CHAMBERS SHALL MEET ASTM F 2418 -05 "STANDARD
SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED
WALL STORMWATER COLLECTION CHAMBERS
6" MIN.
GRANULAR WELL GRADED SOIUAGGREGATE MIXTURES,
<35% FINES. COMPACT IN 6 IN LIFTS TO 95% PROCTOR DENSITY.
SEE THE TABLE OF ACCEPTABLE FILL MATERIALS
3, 357, 4, 467, A -1
5, 56, 57, 6, A -2
67, 68, 7, 78, A -3
8, 89, 9, 10
3, 357, 4, 467, 5, N/A
56, 57
PAVEMENT
SC -740 END CAP
FOR UNPAVED INSTALLATION WHERE
RUTTING FROM VEHICLES MAY OCCUR, I/
INCREASE COVER TO 24 INCHES
1111 I
V III I I I 1I
51"
AASHTO M43 AASHTO M145
DESIGNATION DESIGNATION
N/A N/A
3, 357, 4, 467, N/A
5, 56, 57
INSPECTION PORT
BY DESIGN ENGINEER
'SEE STORMTECH DESIGN MANUAL
12" MIN. TYP.
AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OR EQUAL,
BETWEEN FOUNDATION STONE AND CHAMBERS
SC- 740- -5' -6' WIDE STRIP
SC- 310 -4' WIDE STRIP
r t
T
18" 96"
6" MIN. M IN. MAX'
30
DEPTH OF STONE
TO BE DETERMINED
BY DESIGN ENGINEER
6" MIN.*
COMPACTION /DENSITY
REQUIREMENT
PREPARE PER ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL
AND PREPARATION REQUIREMENTS.
COMPACT IN 6" LIFTS TO A MINIMUM 95%
STANDARD PROCTOR DENSITY. ROLLER GROSS
VEHICLE WEIGHT NOT TO EXCEED 12,000 LBS.
DYNAMIC FORCE NOT TO EXCEED 20,000 LBS.
NO COMPACTION REQUIRED
PLATE COMPACT OR ROLL TO ACHIEVE A
95% STANDARD PROCTOR DENSITY
PLEASE NOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN
CRUSHED ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR NO. 4 STONE.
STORMTECH
ISOLATOR ROW
STORMTECH CHAMBERS
STORMTECH ACCEPTABLE FILL MATERIALS
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
STORMTECH ISOLATORTM ROW MANIFOLD DETAIL
COVER ENTIRE ROW WITH
AASHTO M288 CLASS 2 NON -WOVEN
GEOTEXTILE OR EQUAL
SC- 740 -8' WIDE STRIP
SC- 310 -5' WIDE STRIP
STORMTECH ENDCAP
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
STORMTECH ISOLATORTM ROW DETAIL
BED PERIMETER
NUMBER AND SIZE OF 1
UNDERDRAINS PER
ENGINEER DESIGN
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
B
A
A I
B
TO OUTLET CONTROL
STRUCTURE
STORMTECH UNDERDRAIN DETAIL
NOTES:
1. ALL DESIGN SPECIFICATIONS FOR STORMTECH CHAMBERS
SHALL BE IN ACCORDANCE WITH THE STORMTECH DESIGN MANUAL.
2. THE INSTALLATION OF STORMTECH CHAMBERS SHALL BE IN
ACCORDANCE WITH THE LATEST STORMTECH INSTALLATION
INSTRUCTIONS.
3. THE CONTRACTOR IS ADVISED TO REVIEW AND UNDERSTAND
THE INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM
INSTALLATION. CALL 1- 888 892 -2694 OR VISIT
WWW.STORMTECH.COM TO RECEIVE A COPY OF THE LATEST
STORMTECH INSTALLATION INSTRUCTIONS.
4. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD
FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF
THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS.
PAVEMENT
SC -740 CHAMBER
AASHTO M288 CLASS 2
NON -WOVEN GEOTEXTILE
A
STORMTECH SINGLE TEE
MANUFACTURED BY ADS
STORMTECH CHAMBER
PERFORATED
UNDERDRAIN PIPE
STORMTECH CHAMBER
FOUNDATION STONE
BENEATH CHAMBER
STONE BEDDING UNDER
DRAINAGE PIPE (PER DESIGN)
A
1
ADS 601 GEOTEXTILE
OR EQUAL
4x PIPE 0 MIN
FOR INFORMATION
CALL 1- 888 892 -2694
STORMTECH TRIPLE MANIFOLD
MANUFACTURED BY ADS
FOUNDATION STONE
BENEATH CHAMBER
ADS 601 GEOTEXTILE
OR EQUAL
4x PIPE 0 MIN
STONE BEDDING UNDER
DRAINAGE PIPE (PER DESIGN)
SECTION A_A
SECTION B_B
PERFORATED
UNDERDRAIN PIPE
STORMTECH INSPECTION PORT DETAIL
A
STORMTECH DOUBLE MANIFOLD
MANUFACTURED BY ADS
AVAIL STANDARD HEADERS AVAILABLE
A
24" HDPE PIPE
IN
CLASS "C" CONCRETE
AASHTO M288 CLASS 2
NON -WOVEN GEOTEXTILE
ISOLATOR ROW
MANHOLE
INLET PIPE
INVERT
INVERT
FLOOR BOX FRAME AND LID W /S.S.
CAP SCREW LID CLOSURE
INSPECTION PORT WITH SCREW -IN CAP
INSPECTION PORT TO BE
ATTACHED THROUGH
KNOCK -OUT LOCATED
AT CENTER OF CHAMBER
FOR STORMTECH INFORMATION CALL 1- 888 892 -2694
CROWN MATCHING
ECCENTRIC MANIFOLD
SECTION A A
INVERT MATCHING
ECCENTRIC MANIFOLD
SECTION A_A
ADS MANIFOLD DETAILS
SIZE ON SIZE MANIFOLD
SECTION A A
OVERFLOW WEIR
STORMTECH CHAMBERS
MANIFOLDS ARE DESIGNED TO BE COUPLED
TO STORMTECH PREFABRICATED END CAPS.
WHEN USING STANDARD END CAPS,
CORRUGATED PIPE UP TO 18 INCHES CAN BE
INSERTED DIRECTLY INTO THE END CAP. FOR
24" INLET PIPES, A CORRUGATED TO SMOOTH
PIPE ADAPTER IS REQUIRED.
PLACE MINIMUM 12.5' OF AASHTO M288 CLASS 1
WOVEN GEOTEXTILE OVER BEDDING STONE FOR
SCOUR PROTECTION AT ALL CHAMBER INLET ROWS
STORMTECH CHAMBERS
BOTTOM OF CHAMBER
ELEV.
BOTTOM OF FOUNDATION
STONE ELEV.
SECTION B_B
MAXIMUM FINISHED GRADE ELEV.
MINIMUM FINISHED GRADE ELEV.
72.8
IN
SECTION A_A
STORMTECH ELEVATIONS
ISOLATOR ROW
UNDERDRAIN PIPE
INVERT
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
WEIR PLATE
ELEV.
24" ISOLATOR ROW PIPE
INVERT
MANIFOLD PIPE
PROPOSED LAYOUT: SYSTEM 1
(350) SC -740 CHAMBERS
STORAGE PER CHAMBER: 74.9 CF
INSTALLED WITH 6" COVER STONE, 6" BASE STONE, 40% VOIDS
TOTAL SYSTEM 1 STORAGE: 26,215 CF
STORMTECH STUB
PREFABRICATED END CAP
ISOLATOR ROW
hhh hi
90.7" ACTUAL LENGTH
85.4" INSTALLED
l l _d wk U C&_
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W x H x INSTALLED LENGTH)
CHAMBER STORAGE
MINIMUM INSTALLED STORAGE
WEIGHT
STUBS AT TOP OF END
CAP FOR PARTS NUMBERS
ENDING WITH "T"
PART# CHAMBER
SC740EPEO6T SC-740
SC740EPEO6B SC-740
SC740E PEO8T
SC740EPEO8B
SC740EPE1OT
SC740EPE10B
SC740E PE 12T
SC740EPE12B
SC740EPE15T
SC740EPE15B
SC740EPE18T
SC740EPE18B
SC740E PE24B
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
SC-740
PIP E SIZE
6 in (150 mm)
6 in (150 mm)
8 in (200 mm)
8 in (200 mm)
10 in (250 mm)
10 in (250 mm)
12 in (300 mm)
12 in (300 mm)
15 in (375 mm)
15 in (375 mm)
18 in (450 mm)
18in(450mm)
24 in (600 mm)
ALL STUBS, EXCEPT FOR THE SC740EPE24B
ARE PLACED AT BOTTOM OF END CAP SUCH
THAT THE OUTSIDE DIAMETER OF THE STUB IS
FLUSH WITH THE BOTTOM OF THE END CAP.
FOR ADDITIONAL INFORMATION CONTACT
STORMTECH AT 1- 888-892 -2694.
PLACE MINIMUM 12.5° OF AASHTO
M288 CLASS 1 WOVEN GEOTEXTILE
OVER BEDDING STONE FOR SCOUR
PROTECTION AT ALL CHAMBER
INLET ROWS
SC -740 CHAMBER
HT
MSO WM CLASS 2
FOUNDATION STONE BENEATH
CHAMBER (PER DESIGN)
4'5\ s PERFORATED UNDER N ILE
D RAIN PPE
51
51.0" x 30.0" x 85.4"
45.9 CUBIC FEET
74.9 CUBIC FEET
75 LBS.
6" PERFORATED UNDERDRAIN
(SIZE TBD BY ENGINEER)
OUTLET CONTROL STRUCTURE
(TBD BY ENGINEER)
24" PRE -FAB ENDCAP AT
ALL 24" CONNECTIONS
(SC740EPE24B)
30.0"
STUBS AT BOTTOM OF END
CAP FOR PARTS NUMBERS
ENDING WITH "B"
A B C
10.90 in (277 mm) 18.50 in (470 mm) N/A
1
10.90 in (277 mm) N/A 0.50 in
N/A (13 mm)
1
12.20 In mm in mm
12.20 in 310 mm N/A 0.60 in (15 mm)
:13.40 in 13.40 in (340mm)14.50iN� 68 N/A
mm )t (340 mm)
0.70 in (18 mm) 1 1
14.70 in (373 mm) 12.50 in (318 mm)1 N/A
14.70 in (373 mm) N/A f 1.20 in (30 mm)
N/A
18.40 in (467 mm) 9.00 in (2
18.40 In (467 mm) N29 /A mm)
1.30 in (33 mm)
19.70'n 500 mm)1 5.00 in (127 mm) 1 60 in 41 mm
19.70 N/A in 1
18.50 in (470 mm) N/A 0.10 in (3 mm)
FOR THE SC740EPE24B THE 24"
STUB LIES BELOW THE BOTTOM OF THE
END CAP APPROXIMATELY 1.75
BACKFILL MATERIAL SHOULD BE
REMOVED FROM BELOW THE N -12 STUB
SO THAT THE FITTING SETS LEVEL.
TECHNICAL DETAILS
ALL MANIFOLDS SHOWN AS 18" X 18"
(SIZE TBD BY ENGINEER)
24" CONNECTION TO
ISOLATOR ROW TYP.
MANHOLE WITH WIER, TYP. 4 PLACES
(TBD BY ENGINEER)
CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN
SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN
SPECIFICATIONS LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL
INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD.
STORMTECH SC -740 CHAMBER LAYOUT
This drawing was prepared to support the
design engineer for the proposed
conversion. It is the ultimate responsibility
of the design engineer to
assure that the stormwater system's design
is in full compliance with all
applicable laws and regulations. It is the
design engineer's responsibility
to ensure that the StormTech products are
designed in accordance with
StormTech minimum requirements.
StormTech LLC does not approve plans,
sizing, or system designs. The design
engineer is responsible for all
design decisions.
SAVED AS
DRAWN BY
SCALE
DATE
H
U O
W
J
Et
ra. W
J (n
W Q
2 a.
ce O
Q
U d
REVISIONS
DRAWING TITLE
PROJECT NO.
SYSTEM 1
STORMTECH SC -740
CHAMBER DETAIL SHEET
JLB
NTS
11 -27-06
CHECKED BY
DATE
DRAWING NO.