HomeMy WebLinkAbout06120001 Large Plan for Old Meridian Place, Sec. 1 pg. 22STUB SIZE
HEADER PIPE SIZES
48 42 36
30
24
18 15 I 12"
8
AVAIL; AVAIL AVAIL
AVAIL
AVAIL
X 10
AVAIL, AVAIL AVAIL
AVAIL
AVAIL
AVAIL
AVAIL AVAIL AVAIL
AVAIL
AVAIL
AVAIL AVAIL
AVAIL
7
N'.
AVAIL AVAIL AVAIL
AVAIL
AVAIL
AVAIL AVAIL AVAIL
AVAIL
AVAIL AVAIEAVAIL
i
AVAIL
T
AVAIL AVAIL AVAIL
AVAIL
AVAIL
AVAIL
AVAIL
AVAIL
AVAIL' AVAIL AVAIL
AVAIL
CATCH BASIN
OR
MANHOLE
SUMP DEPTH
BY DESIGN
ENGINEER
0
FOR STORMTECH INFORMATION
CALL 1- 888 -892 -2694
MATERIAL LOCATION
THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE
THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD
BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOR
EARTH AND LIVE LOADS, WITH CONSIDERATION FOR
IMPACT AND MULTIPLE VEHICLE PRESENCES.
ADS 601 GEOTEXTILE OR EQUAL
FILL MATERIAL FROM 18"
TO GRADE ABOVE CHAMBERS
'Cj FILL MATERIAL FOR 6" TO 18" GRANULAR WELL GRADED
ELEVATION ABOVE CHAMBERS SOILJAGGREGATE MIXTURES,
(24" FOR UNPAVED INSTALLATIONS) <35% FINES.
Bi EMBEDMENT STONE SURROUNDING
AND TO A 6" ELEVATION ABOVE
CHAMBERS
CLEAN ANGULAR STONE WITH THE
MAJORITY OF PARTICLES BETWEEN
'/4 2 INCH
PLEASE NOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN
CRUSHED ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR NO. 4 STONE.
A FOUNDATION STONE BELOW
CHAMBERS
VIPIP
SC -740 CHAMBER
3 /4 2 INCH CLEAN,
CRUSHED, ANGULAR STONE
I =11', III =III l= I =11
I 11 11 II-II III II II -11 I ii
ii I I 1 II I 1v
DESIGN ENGINEER IS RESPONSIBLE FOR
ENSURING THE REQUIRED BEARING
CAPACITY OF SUBGRADE SOILS"
THIS CROSS SECTION DETAILS THE REQUIREMENTS
NECESSARY TO SATISFY THE LOAD FACTORS SPECIFIED IN THE
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12
FOR EARTH AND LIVE LOADS USING STORMTECH CHAMBERS
SC -740 TYPICAL CROSS SECTION
DESCRIPTION
ANY SOIL/ROCK MATERIALS, NATIVE
SOILS OR PER ENGINEER'S PLANS.
CHECK PLANS FOR PAVEMENT
SUBGRADE REQUIREMENTS.
CLEAN ANGULAR STONE WITH THE
MAJORITY OF PARTICLES BETWEEN
'/4 -2INCH
STORMTECH ACCEPTABLE FILL MATERIALS
MANHOLE WITH
OVERFLOW WEIR
ECCENTRIC
HEADER
PLACE MINIMUM 12.5° OF AASHTO M288
CLASS 1 WOVEN GEOTEXTILE OVER
BEDDING STONE FOR SCOUR PROTECTION
AT ALL CHAMBER INLET ROWS
STORMTECH
PREFABRICATED
END CAPS
r CHAMBERS SHALL MEET ASTM F 2418 -05 "STANDARD
SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED
WALL STORMWATER COLLECTION CHAMBERS
GRANULAR WELL GRADED SOIL /AGGREGATE MIXTURES,
<35% FINES. COMPACT IN 6 IN LIFTS TO 95% PROCTOR DENSITY.
SEE THE TABLE OF ACCEPTABLE FILL MATERIALS
I I 1E'.
II III r
6" MIN.
PAVEMENT
SC -740 END CAP
FOR UNPAVED INSTALLATION WHERE
RUTTING FROM VEHICLES MAY OCCUR
INCREASE COVER TO 24 INCHES
II
I I I Ili=
51"
ACCEPTABLE FILL MATERIALS
STORMTECH SC -740 CHAMBER SYSTEMS
AASHTO M43 AASHTO M145 COMPACTION /DENSITY
DESIGNATION DESIGNATION REQUIREMENT
N/A N/A PREPARE PER ENGINEER'S PLANS. PAVED
INSTALLATIONS MAY HAVE STRINGENT MATERIAL
AND PREPARATION REQUIREMENTS.
3, 357, 4, 467, A -1
5, 56, 57, 6, A -2
67, 68, 7, 78, A -3
8, 89, 9, 10
3, 357, 4, 467, 5, N/A
56, 57
3, 357, 4, 467, N/A
5,56,57
"SEE STORMTECH DESIGN MANUAL
INSPECTION PORT
BY DESIGN ENGINEER
AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OR EQUAL,
BETWEEN FOUNDATION STONE AND CHAMBERS
SC- 740- -5' -6' WIDE STRIP
SC- 310 -4' WIDE STRIP
MAX
1 18" M IN. 96"
6 M I
I.
12" MIN. TYP.
COMPACT IN 6" LIFTS TO A MINIMUM 95%
STANDARD PROCTOR DENSITY. ROLLER GROSS
VEHICLE WEIGHT NOT TO EXCEED 12,000 LBS.
DYNAMIC FORCE NOT TO EXCEED 20,000 LBS.
NO COMPACTION REQUIRED
PLATE COMPACT OR ROLL TO ACHIEVE A
95% STANDARD PROCTOR DENSITY
I
DEPTH OF STONE
TO BE DETERMINED
BY DESIGN ENGINEER
6" MIN."
30"
STORMTECH
ISOLATOR ROW
STORMTECH CHAMBERS
STORMTECH ISOLATORTm ROW MANIFOLD DETAIL
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
COVER ENTIRE ROW WITH
AASHTO M288 CLASS 2 NON -WOVEN
GEOTEXTILE OR EQUAL
SC- 740 -8' WIDE STRIP
SC- 310 -5' WIDE STRIP
STORMTECH ISOLATORTM ROW DETAIL
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
FOR STORMTECH INFORMATION
CALL 1- 888 -892 -2694
STORMTECH UNDERDRAIN DETAIL
BED PERIMETER
NUMBER AND SIZE OF
UNDERDRAINS PER
ENGINEER DESIGN n
TO OUTLET CONTROL
STRUCTURE
NOTES:
1. ALL DESIGN SPECIFICATIONS FOR STORMTECH CHAMBERS
SHALL BE IN ACCORDANCE WITH THE STORMTECH DESIGN MANUAL.
2. THE INSTALLATION OF STORMTECH CHAMBERS SHALL BE IN
ACCORDANCE WITH THE LATEST STORMTECH INSTALLATION
INSTRUCTIONS.
3. THE CONTRACTOR IS ADVISED TO REVIEW AND UNDERSTAND
THE INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM
INSTALLATION. CALL 1- 888 892 -2694 OR VISIT
WWW.STORMTECH.COM TO RECEIVE A COPY OF THE LATEST
STORMTECH INSTALLATION INSTRUCTIONS.
4. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD
FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF
THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS.
PAVEMENT
4" PVC RISER
SC -740 CHAMBER
AASHTO M288 CLASS 2
NON -WOVEN GEOTEXTILE
7.
STORMTECH INSPECTION PORT DETAIL
A
STORMTECH SINGLE TEE
MANUFACTURED BY ADS
A
STORMTECH CHAMBER
PERFORATED
UNDERDRAIN PIPE
STORMTECH CHAMBER
FOUNDATION STONE
BENEATH CHAMBER
ADS 601 GEOTEXTILE
OR EQUAL
4x PIPE 0 MIN
STONE BEDDING UNDER
DRAINAGE PIPE (PER DESIGN)
FOR INFORMATION
CALL 1- 888 892 -2694
STONE BEDDING UNDER
DRAINAGE PIPE (PER DESIGN)
SECTION A A
SECTION B_B
STORMTECH TRIPLE MANIFOLD
MANUFACTURED BY ADS
STORMTECH DOUBLE MANIFOLD
MANUFACTURED BY ADS
FOUNDATION STONE
BENEATH CHAMBER
ADS 601 GEOTEXTILE
OR EQUAL
4x PIPE 0 MIN
PERFORATED
UNDERDRAIN PIPE
A
A
AVAIL STANDARD HEADERS AVAILABLE
FLOOR BOX FRAME AND LID W /S.S.
CAP SCREW LID CLOSURE
INSPECTION PORT WITH SCREW -IN CAP
CLASS "C" CONCRETE
AASHTO M288 CLASS 2
NON -WOVEN GEOTEXTILE
INSPECTION PORT TO BE
ATTACHED THROUGH
KNOCK -OUT LOCATED
AT CENTER OF CHAMBER
CROWN MATCHING
ECCENTRIC MANIFOLD
SECTION A_A
IN
8.
INVERT MATCHING
ECCENTRIC MANIFOLD
SECTION A A
SIZE ON SIZE MANIFOLD
SECTION A A
MANIFOLDS ARE DESIGNED TO BE COUPLED
TO STORMTECH PREFABRICATED END CAPS.
WHEN USING STANDARD END CAPS,
CORRUGATED PIPE UP TO 18 INCHES CAN BE
INSERTED DIRECTLY INTO THE END CAP. FOR
24" INLET PIPES, A CORRUGATED TO SMOOTH
PIPE ADAPTER IS REQUIRED.
ADS MANIFOLD DETAILS
ISOLATOR ROW
24" HDPE PIPE
MANHOLE
OVERFLOW WEIR
STORMTECH CHAMBERS
INLET PIPE
INVERT
INVERT
BOTTOM OF CHAMBER
ELEV.
STORMTECH CHAMBERS
A
BOTTOM OF FOUNDATION
STONE ELEV.
FOR STORMTECH INFORMATION CALL 1- 888 892 -2694
PLACE MINIMUM 12.5' OF AASHTO M288 CLASS 1
WOVEN GEOTEXTILE OVER BEDDING STONE FOR
SCOUR PROTECTION AT ALL CHAMBER INLET ROWS
SECTION B_B
B—
IN
MAXIMUM FINISHED GRADE ELEV.
MINIMUM FINISHED GRADE ELEV.
SECTION A_A
UNDERDRAIN PIPE
INVERT
STORMTECH ELEVATIONS
10.0
63.2'
4 4
I L 1
I
FOR STORMTECH INFORMATION
CALL 1- 888 892 -2694
WEIR PLATE
ELEV.
24" ISOLATOR ROW PIPE
INVERT
MANIFOLD PIPE
PROPOSED LAYOUT: SYSTEM 2
(400) SC -740 CHAMBERS
STORAGE PER CHAMBER: 74.9 CF
INSTALLED WITH 6" COVER STONE, 6" BASE STONE, 40% VOIDS
TOTAL SYSTEM 2 STORAGE: 29,960 CF
ISOLATOR ROW
239.6'
ISOLATOR ROW
STORMTECH STUB
PREFABRICATED END CAP
SC740E PEO8T
SC740EPEO8B
SC740EPE1OT
SC740EPE10B
SC740EPE12T
SC740EPE12B
SC740EPE15T
SC740EPE15B
SC740EPE18T
SC740EPE18B
SC74OEPE24B
90.7" ACTUAL LENGTH
NOMINAL CHAMBER SPECIFICATIONS
SIZE (W x H x INSTALLED LENGTH)
CHAMBER STORAGE
MINIMUM INSTALLED STORAGE
WEIGHT
STUBS AT TOP OF END
CAP FOR PARTS NUMBERS
ENDING WITH "T"
24" CONNECTION AT ISOLATOR ROW TYP.
24" PRE -FAB ENDCAP AT ALL 24" CONNECTIONS
ALL STUBS, EXCEPT FOR THE SC740EPE24B
ARE PLACED AT BOTTOM OF END CAP SUCH
THAT THE OUTSIDE DIAMETER OF THE STUB IS
FLUSH WITH THE BOTTOM OF THE END CAP.
FOR ADDITIONAL INFORMATION CONTACT
STORMTECH AT 1- 888-892 -2694.
ISOLATOR ROW
ii I-'IF_-
I I [_"I J F _T
-A
51.0" x 30.0" x 85.4"
45.9 CUBIC FEET
74.9 CUBIC FEET
75 LBS.
STUBS AT BOTTOM OF END
CAP FOR PARTS NUMBERS
ENDING WITH "B"
PART CHAMBER PIPE SIZE A B C
SC74OEPEO6T SC-740 6 in (150 mm) 10.90 in (277 mm) 18.50 in (470 mm) N/A
SC740EPEO6B 1 SC-740 6 in (150 mm) 10.90 in (277 mm) N/A 0.50 in (13 mm)
SC-740 8 in (200 mm) 12.20 in (310 mm) 16.50 in (419 mm) N/A
SC-740 8 in (200 mm) 12.20 in (310 mm) N/A 0.60 in (15 mm)
SC-740 10 in (250 mm) 13.40 in (340 mm),14.50 in (368 mm) N/A
SC-740 10 in (250 mm) 13.40 in (340 mm )I N/A 0.70 in (18 mm)
SC-740 12 in (300 mm) 14.70 in (373 mm)112.50 in (318 mm) N/A
I
SC-740 12 in (300 mm) 14.70 in (373 mm); N/A 1.20 in (30 mm)
SC -740 15 in (375 mm) 18.40 in (467 mm), 9.00 in (229 mm) N/A
SC-740 15 in (375 mm) 18.40 in (467 mm)I N/A 1.30 in (33 mm)
t
18 in 450 mm 19.70 in 500 m
SC-740 m 5 00 In 127 mm
N/A
I
SC-740 I 18 in (450 mm) 19.70 in (500 mm)I N/A 1.60 in (41 mm)
SC-740 24 in (600 mm) 18.50 in (470 mm)1 N/A 0.10 in (3 mm)
FOR THE SC740EPE24B THE 24"
STUB LIES BELOW THE BOTTOM OF THE
END CAP APPROXIMATELY 1.75
BACKFILL MATERIAL SHOULD BE
REMOVED FROM BELOW THE N -12 STUB
SO THAT THE FITTING SETS LEVEL.
TECHNICAL DETAILS
MANHOLE WITH WEIR, TYP. 5 PLACES
(TBD BY ENGINEER)
OUTLET CONTROL STRUCTURE
(TBD BY ENGINEER)
6" PERFORATED UNDERDRAIN
(SIZE TBD BY ENGINEER)
PLACE MINIMUM 12.5' OF AASHTO M288
CLASS 1 WOVEN GEOTEXTILE OVER
BEDDING STONE FOR SCOUR
PROTECTION AT ALL CHAMBER INLET
ROWS
CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN
SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN
SPECIFICATIONS LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL
INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD.
STORMTECH SC -740 CHAMBER LAYOUT
H
U O
w
)1<
o
a w
J (n
W Q
2 a.
O
Q ct
U d
This drawing was prepared to support the
design engineer for the proposed
conversion. It is the ultimate responsibility
of the design engineer to
assure that the stormwater system's design
is in full compliance with all
applicable laws and regulations. It is the
design engineer's responsibility
to ensure that the StormTech products are
designed in accordance with
StormTech minimum requirements.
StormTech LLC does not approve plans,
sizing, or system designs. The design
engineer is responsible for all
design decisions.
REVISIONS DATE
DRAWING TITLE
SYSTEM 2
STORMTECH SC -740
CHAMBER DETAIL SHEET
SAVED AS
DRAWN BY
SCALE
DATE
PROJECT NO.
JLB
NTS
11 -27-06
CHECKED BY
DRAWING NO.
Subsurface Stormwater Management sm
S:\52605S1\dwg\C803-Underground Details.dwg, SYSTEM 2, 12/1/2006 9:04:26 AM, bhuff, 1:1.04412
PROJECT NAME
Detention- Retention. Recharge