Loading...
HomeMy WebLinkAbout06120001 Large Plan for Old Meridian Place, Sec. 1 pg. 23STUB SIZE HEADER PIPE SIZES 48" 42" 36" 30" 24" 18" 15" 12" 10" 8" 24" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 18" AVAIL AVAIL AVAIL' AVAIL 15" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 12" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 10" AVAIL AVAIL AVAIL AVAIL AVAIL r 8" AVAIL AVAIL AVAIL AVAIL AVAIL' AVAIL AVAIL AVAIL AVAIL AVAIL 6" AVAIL AVAIL AVAIL ST MATERIAL LOCATION FILL MATERIAL FROM 18" TO GRADE ABOVE CHAMBERS C) FILL MATERIAL FOR 6" TO 18" ELEVATION ABOVE CHAMBERS (24" FOR UNPAVED INSTALLATIONS) EMBEDMENT STONE SURROUNDING AND TO A 6" ELEVATION ABOVE CHAMBERS A) FOUNDATION STONE BELOW CHAMBERS CATCH BASIN OR MANHOLE SUMP DEPTH BY DESIGN ENGINEER SC -740 TYPICAL CROSS SECTION STORMTECH SC -740 CHAMBER SYSTEMS DESCRIPTION ANY SOIUROCK MATERIALS, NATIVE SOILS OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. GRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES, <35% FINES. CLEAN ANGULAR STONE WITH THE MAJORITY OF PARTICLES BETWEEN 3 /4 2 INCH CLEAN ANGULAR STONE WITH THE MAJORITY OF PARTICLES BETWEEN 3 2 INCH PLEASE NOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN CRUSHED ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS CLEAN, CRUSHED, ANGULAR NO. 4 STONE. STORMTECH ACCEPTABLE FILL MATERIALS MANHOLE WITH OVERFLOW WEIR ECCENTRIC HEADER PLACE MINIMUM 12.5' OF AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OVER BEDDING STONE FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS STORMTECH PREFABRICATED END CAPS ACCEPTABLE FILL MATERIALS AASHTO M43 AASHTO M145 COMPACTION /DENSITY DESIGNATION DESIGNATION REQUIREMENT N/A N/A 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 3, 357, 4, 467, 5, N/A 56, 57 3, 357, 4, 467, N/A 5, 56, 57 A -1 COMPACT IN 6" LIFTS TO A MINIMUM 95% A -2 STANDARD PROCTOR DENSITY. ROLLER GROSS A -3 VEHICLE WEIGHT NOT TO EXCEED 12,000 LBS. DYNAMIC FORCE NOT TO EXCEED 20,000 LBS. STORMTECH ISOLATORTm ROW MANIFOLD DETAIL INSPECTION PORT BY DESIGN ENGINEER AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OR EQUAL, BETWEEN FOUNDATION STONE AND CHAMBERS SC- 740- -5 -6' WIDE STRIP SC- 310 -4" WIDE STRIP PLATE COMPACT OR ROLL TO ACHIEVE A 95% STANDARD PROCTOR DENSITY TM PREPARE PER ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. NO COMPACTION REQUIRED STORMTECH ISOLATOR ROW STORMTECH CHAMBERS FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 COVER ENTIRE ROW WITH AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE OR EQUAL SC- 740 -8' WIDE STRIP SC- 310 -5' WIDE STRIP STORMTECH ENDCAP FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 STORMTECH UNDERDRAIN DETAIL NOTES: 1. ALL DESIGN SPECIFICATIONS FOR STORMTECH CHAMBERS SHALL BE IN ACCORDANCE WITH THE STORMTECH DESIGN MANUAL. 2. THE INSTALLATION OF STORMTECH CHAMBERS SHALL BE IN ACCORDANCE WITH THE LATEST STORMTECH INSTALLATION INSTRUCTIONS. 3. THE CONTRACTOR IS ADVISED TO REVIEW AND UNDERSTAND THE INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM INSTALLATION. CALL 1- 888 892 -2694 OR VISIT VVWW.STORMTECH.COM TO RECEIVE A COPY OF THE LATEST STORMTECH INSTALLATION INSTRUCTIONS. 4. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE PAVEMENT 4" PVC RISER SC -740 CHAMBER A STORMTECH SINGLE TEE MANUFACTURED BY ADS A FOR INFORMATION CALL 1- 888 892 -2694 STORMTECH TRIPLE MANIFOLD MANUFACTURED BY ADS AVAIL STANDARD HEADERS AVAILABLE ADS STORMTECH DOUBLE MANIFOLD MANUFACTURED BY ADS FLOOR BOX FRAME AND LID W /S.S. CAP SCREW LID CLOSURE INSPECTION PORT WITH SCREW -IN CAP A CLASS "C" CONCRETE AASHTO M288 CLASS 2 NON- WO\ /EN GEOTEXTILE INVERT INSPECTION PORT TO BE ATTACHED THROUGH KNOCK -OUT LOCATED AT CENTER OF CHAMBER FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 STORMTECH INSPECTION PORT DETAIL A CROWN MATCHING ECCENTRIC MANIFOLD SECTION A A INVERT MATCHING ECCENTRIC MANIFOLD SECTION A A SIZE ON SIZE MANIFOLD SECTION A A LD DETAILS STORMTECH CHAMBERS INLET PIPE INVERT BOTTOM OF CHAMBER ELEV. MANIFOLDS ARE DESIGNED TO BE COUPLED TO STORMTECH PREFABRICATED END CAPS. WHEN USING STANDARD END CAPS, CORRUGATED PIPE UP TO 18 INCHES CAN BE INSERTED DIRECTLY INTO THE END CAP. FOR 24" INLET PIPES, A CORRUGATED TO SMOOTH PIPE ADAPTER IS REQUIRED. BOTTOM OF FOUNDATION STONE ELEV. SECTION B_B C MINIMUM FINISHED GRADE ELEV. IN SECTION A_A STORMTECH ELEVATIONS PROPOSED LAYOUT: SYSTEM 3 (1913) SC -740 CHAMBERS STORAGE PER CHAMBER: 88.4 CF INSTALLED WITH 6" COVER STONE, 18" BASE STONE, 40% VOIDS TOTAL SYSTEM 3 STORAGE: 169,109 CF ALL MANIFOLDS SHOWN AS 18" X 18" (SIZE TBD BY ENGINEER) MANHOLE WITH WEIR (TBD BY ENGINEER) TYP. 8 PLACES 0 30" NYLOPLAST UNIT (DESIGN BY OTHERS) WEIR PLATE ELEV. 24" ISOLATOR ROW PIPE INVERT MANIFOLD PIPE STORMTECH STUB PREFABRICATED END CAP ISOLATOR ROW INSPECTION PORT TYP. 12 PLACES STUBS AT TOP OF END CAP FOR PARTS NUMBERS ENDING WITH "T" PART CHAMBER PIPE SIZE SC740EPEO6T SC-740 i t SC740EPEO6B SC-740 SC740EPEO8T SC740EPEO8B SC740EPE1OT SC740EPE1OB SC740EPE12T SC-740 6 in (150 mm) 6 in (150 mm) SC-740 8 in (200 mm) SC-740 8 in (200 mm) SC-740 10 in (250 mm) 13.40 in (340 mm) 14.50 in (368 mm) N/A SC-740 10 in (250 mm) 113.40 in (340 mm) N/A 0.70 in (18 mm) 12 in (300 mm) 114.70 in (373 mm) 12.50 in (318 mm) N/A SC740EPE12B SC-740 12 in (300 mm) SC740EPE15T SC-740 SC740EPE15B SC-740 SC740EPE18T SC-740 SC740EPE18B SC-740 SC740EPE24B SC-740 ALL STUBS, EXCEPT FOR THE SC74OEPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1- 888-892 -2694. 14.70 in (373 mm) N/A 1.20 in (30 mm) 15 in (375 mm) 1 8.40 in (467 mm) 9.00 in (229 mm) N/A 15 in (375 mm) 118.40 in (467 mm) I N/A 1.30 in (33 mm) 18 in (450 mm) 1 19.70 in (500 mm) 5.00 in (127 mm) N/A 18 in 450 mm 19.70 in 500 mm N/A 1.60 in (41 mm) 24 in (600 mm) 1 18.50 in (470 mm)', N/A 0.10 in (3 mm) TECHNICAL DETAILS 480.2 191.4' 1090 in (277 mm) 18.50 in (470 mm N/A 10.90 in (277 mm) N/A 0.50 in (13 mm) 12.20 in (310 mm) 16.50 in (419 mm) N/A 12.20 in (310 mm) N/A 0.60 in (15 mm) PLACE MINIMUM 12.5' OF AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OVER BEDDING STONE FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS STUBS AT BOTTOM OF END CAP FOR PARTS NUMBERS ENDING WITH "B" A B C FOR THE SC740EPE24B THE 24" STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75 BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N -12 STUB SO THAT THE FITTING SETS LEVEL. OUTLET CONTROL STRUCTURE (TBD BY ENGINEER) F- 00 uJ )1< Ct a w J (n W Q 2 a_ ct o Q U a This drawing was prepared to support the design engineer for the proposed conversion. It is the ultimate responsibility of the design engineer to assure that the stormwater system's design is in full compliance with all applicable laws and regulations. It is the design engineer's responsibility to ensure that the StormTech products are designed in accordance with StormTech minimum requirements. StormTech LLC does not approve plans, sizing, or system designs. The design engineer is responsible for all design decisions. REVISIONS SAVED AS DRAWN BY SCALE DATE PROJECT NO. JLB NTS 11 -27 -06 DATE DRAWING TITLE SYSTEM 3 STORMTECH SC -740 CHAMBER DETAIL SHEET CHECKED BY DRAWING NO. \6. 1 11 III 1 111 1 I III 'I !Iss, a• 1 1' 111 '11 1 1 -1 I L =1 I 1 III -111 11 111 =11 11= II 111 IFT 111-111 I -III- III THE INSTALLED CHAMBER SYSTEM SHALL PROVIDE THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOR EARTH AND LIVE LOADS, WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. FOR STORMTECH INFORMATION CALL 1-888 -892 -2694 SC-740 CHAMBER 2 INCH CLEAN, CRUSHED, ANGULAR STONE ADS 601 GEOTEXTILE OR EQUAL DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING THE REQUIRED BEARING CAPACITY OF SUBGRADE SOILS* CHAMBERS SHALL MEET ASTM F 2418 -05 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS GRANULAR WELL GRADED SOIUAGGREGATE MIXTURES, <35% FINES. COMPACT IN 6 IN LIFTS TO 95% PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS SC-740 END CAP PAVEMENT FOR UNPAVED INSTALLATION WHERE RUTTING FROM VEHICLES MAY OCCUR, j INCREASE COVER TO 24 INCHES 14 -111 1 1- -11-1 II a1 rt 111_; 6" MIN. -•--1 1 -1- 51" THIS CROSS SECTION DETAILS THE REQUIREMENTS NECESSARY TO SATISFY THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SECTION 12.12 FOR EARTH AND LIVE LOADS USING STORMTECH CHAMBERS I I I I 'I y 18" 96" 6" MIN. MIN. MAX. I *SEE STORMTECH DESIGN MANUAL 30" DEPTH OF STONE TO BE DETERMINED TT BY DESIGN ENGINEER 6" MIN.* I 12" MIN. TYP. BED PERIMETER NUMBER AND SIZE OF UNDERDRAINS PER ENGINEER DESIGN FOR STORMTECH INFORMATION CALL 1-888- 892 -2694 A TO OUTLET CONTROL STRUCTURE STORMTECH CHAMBER PERFORATED UNDERDRAIN PIPE FOUNDATION STONE BENEATH CHAMBER STORMTECH CHAMBER ADS 601 GEOTEXTILE OR EQUAL 4x PIPE 0 MIN STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) SECTION B_B FOUNDATION STONE BENEATH CHAMBER ADS 601 GEOTEXTILE OR EQUAL 4x PIPE 0 MIN STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) SECTION A_A PERFORATED UNDERDRAIN PIPE IN ISOLATOR ROW 24" HDPE PIPE MANHOLE STORMTECH CHAMBERS OVERFLOW WEIR PLACE MINIMUM 12.5' OF AASHTO M288 CLASS 1 WOVEN GEOTEXTILE OVER BEDDING STONE FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS MAXIMUM FINISHED GRADE ELEV. UNDERDRAIN PIPE INVERT FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 90.7" ACTUAL LENGTH 85.4" INSTALLED F1- -I IH i .IC IJJ FElTIL1H NOMINAL C HAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) CHAMBER STORAGE MINIMUM INSTALLED STORAGE WEIGHT B L 51.0" x 30.0" x 85.4" 45.9 CUBIC FEET 74.9 CUBIC FEET 75 LBS. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND LOAD FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD. STORMTECH SC -740 CHAMBER LAYOUT