Loading...
HomeMy WebLinkAboutC200 Site Development PlanALL EXISTING OFF-SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW 913.7 1914.931 915.4 28.54 VAR. D.U.& 61.50' 6G.73/ X 15 R D.E. 914.3 V.3° 15' R.D.E. 913.7 x@ uj c 60 -f 61 o 916.1 915.7 iz 915.9 73 915.4 62.30' 915.3 915.0 76 v 915.5 915.0 oeo� 30 L. L 12 R.C.P. 1914.371 121.34' 0.60% 1+50 1+00 0+ |g14.81 913.7 915 3 915.6 913.5 915.8 915.4 915.1 60.08' 914.5 915.0 914.18 914.18 6498' 914.3 65.00' 914.8 1914.7 912.5 20' D.&U.E. 913.6 914.5 914.5 914.4 914.5 914.5 915.2. 914.5 914.6 914.5 8.85' 914.3 NOTE TO CONTRACTOR: CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS A F TE R CONSTRUCTION B E G I N S ARE S L E L Y THE CONTRACTOR'S R E S P N S I B I L I TY ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. X 120.00 70 ^x 915.6 124.13 916.431 1.20% |g15.8.6 ALTO 2+90.86. 2+50 2+00 |9N5.41| 915.11 917 918 919 81.52' 73.00' 20' D.&U.E. 014.71 33.68' 914.53 1913.961 73.17' 15' D.E. 52.48' 914.8 0.60% 54 915.5 120.00' 120.00 120.00' 120.00 917 916 915 97.00' |y13.741 20' D.U.&S.S.E. |014.D4| v /914.41 xx|g14. 82 915.3 55.00' |g14.34 55.00' 914.2 LAKE �83 N.P.= 908.80 2 YEAR E 10 YEAR ELE\(=910.82 100 YEAR ELE\(=912.52 BOTTOM ELE\(=898.80 55.00' 55.00 5.�.E. X 1014`51 X H.P. r+*5.se 914.90 0.60% D.U.&S.S.E. 55.00' x 1914.91 X X 55.00' 914.8 914.381 65.00' 914.5 65.00 45.68' 14.12 914.23 913.8 44�� 915 2 65.00' 55.00' �0�u 42 916.5 918. r�'``�`v` 3' STONE SHOULDER 100' 60' oo cNi o IN III II �N� II EMERGENCY OVERFLOW ROUTE e-" I NOTE: DRA|N 3WALE T0 Ex. l2 U C.W.P __EX 12 |wV. |NV.=911.20 x T7 D.E. 191 O L��. 55.00' EARTHWORK: |g14.O x x 19131 |ulz�� t„; 55.00' 65.00r 1. EXCAVATION A. Excavated material that is suitable may uo used 'for fills. All unsuitable material and all surplus excavated material not required shall be removed from the site. B. Provide and place any additional fill material from offsite as may be necessary to produce the grades required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the source approved by the Developer. It will be the responsibility of the Contractor for any costs for fill needed. 2. REMOVAL OF TREES A. All trees and stumps shall be removed from areas to be occupied by a road surface or structure area. Trees and stumps shall not be buried on site. J. PROTECTION OF TREES A. The Contractor shox, at the direction of the Developer, endeavor to save and protect trees of value and worth which do not impair construction of improvements as designed. B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with respect to protective measure to be token, if any, to preserve such trees. 4. REMOVAL OF TOPSOIL A. All topsoil shall be removed from all areas beneath future pavements or building. Topsoil removal shall be to a minimum depth of 6 inches or to the depth indicated in the geotechmical report provided by the Developer to be excavated or filled. Topsoil should be stored at a location where it will not interfere with construction operations. The topsoil shall be free of debris and stones. UTILITIES A. Rules and regulation governing the respective utility shall be observed in executing all work under this section. B. It shall be the responsibility of the Contractor to determine the location of existing underground utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free 1-800-382-5544 within Indiana or 1-800-428-5200 outside Indiana. O. SITE GRADING A. Do all cuttmg, fil|ing, compacting of fills and rough grading required to bring entire project area to subgrade as shown on the drawing. B. The tolerance for paved areas shall not exceed 0.05 feet above eotobxs|.ed subgrade. All other areas shall not exceed 0.05 feet plus or minus the established grade. Provide roundings at top and bottom banks and other breaks in grade. C. The Engineer shall be notified when the Contractor has reached the tolerance as stated obove, so that field measurements and spot elevations can be verified by the Engineer. The Contractor shall not remove his equipment from the site until the Engineer has verified that the job meets the above tolerance. FORM \EARTHWRK ��N (`A 1848.01 870 1■10.41110■ �K��� n���� 874.1 {}LL CURB ELEV.= 917.518 "HOLEY MOLEY SAYS: f --/�/l/l--'�/��7_-�������� CALL TOLL FREE �--/�/l/l--z1����--/���/l/l FOR CALLS OUTSIDE OF INDIANA SCALE: 1"= 50' CAUTION 31 920 54.88' LEGEND EXISTING EDGE OF WOODS EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER LOT NUMBER PAD ELEVATION PAD SIZE: 45'x60' (LOTS 35-92) 355(60r (LOTS 1-34, 93-108) (UNLESS OTHERWISE NOTED) mv 19358 STATE OF PROPOSED GRADE MATCH EXISTING PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED SWALE PROPOSED 5' HOME BU|LDER\ (oEvELoPsn SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) DENOTES 4" SUBSURFACE DRAIN TO LOT DENOTES 6" SUBSURFACE DRAIN LEE 2 THE STATION IS LOCATED APPROX. 2.5 MILES NORTHEAST OF ZIONSVILLE; AT THE INTERSECTION OF SHELBOURNE AND WEST 131ST STREET; IN THE SE 1/4 OF THE INTERSECTION; SET IN TOP OF A CONCRETE POST, LEVEL WITH THE ROADWAY; A DEPARTMENT OF NATURAL RESOURCES BRASS CONTROL STATION TABLET, STAMPED "LEE 2 AZI 1989" N.A.V.D. LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (ino|uding, but not limited to, monho|*a, inlets, valves, marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. 0 CO t_LJ u 3 U SHEET NO. JOB wo 4GBOOS1 cc cc 0 p) C200