Loading...
HomeMy WebLinkAboutC4.1 Utility PlanU t7 N 0 MIN. 5' STUB OF 18" RCP BY LANDLORD UTILITY MAINS GAS BY UTILI CO WATER BY LAND ORI F/T BY UTILI Y CO PHASE II 22 L.F. OF PVC SAN. LATERAL 0.1% SLOPE MINIMUM BY LIA)4DLORD STR. No." 19 I TOR 820.17 'RASE BY LANDLORD ex. sanitary mh tc 821.90 Inv n.- 806.56 inv e.- 808.35 FIRE DEPT. CONNECTION PIPE BOLLARDS TYP. 120 L.F. OF PVC SANITARY LATERAL 1.0% SLOPE (KIN.) BY LANDLORD P.i.V. 6" W 148 L.F. 18" RCP 1.42% 6" TAPPING TEE AND VALVE REQUIRED existinJ sanitaf y sewer TRANSFORMER PAD BY GENERAL CONTRACTOR. TRANSFORMER AND ELECTRIC LINE TO TRANSFORMER BY UTILITY COMPANY PHASE I (PREVIOUSLY APPROVED) I\ 21" RCP O 129 L.F. f 21 RCP I PHA III 0 w M CL CL 1 w w z to 0 CV 30' Oi 4" STR. No. 18 TOR= 819.99 (PHASE II) (,KIY LANDLORD 1 84 L.F. OH' RCP .22% i i i i NOTE: THIS PROJECT IS THE NORTHEAST PAD IN THE GREYHOUND COMMONS DEVELOPMENT w CC tZ Q NOTE: UTILITY LINES WILL BE BROUGHT WITHIN 5' OF BUILDING BY THE FOLLOWING WATER GAS ELECTRIC BY LANDLORD BY UTILITY COMPANY BY UTILITY COMPANY to transformer 1 1 1 ex. sanitary mh tc 822.81 tnv n.- 808.21 Inv s.= 808.11 8" pvc FOX HOUND SR431 RAMP vt) i I 4 GREYHOUND COMMONS KEYMAP to w 0 0' 20' SCALE: 1"=20' 40' T W E EXISTING TELEPHONE WATER ELECTRIC GAS SANITARY SEWER PROPERTY LINE EASEMENT WATER VALVE LEGEND G E T W GM EM H 0 PROPOSED GAS LINE ELECTRIC LINE TELEPHONE LINE WATER LINE GAS METER ELECTRIC METER ELECTRICAL TRANSFORMER WATER VALVE WATER METER PIT LIGHT POLE WALL MOUNTED LIGHT SHOEBOX PHASE I SANITARY SEWER PHASE I STORM SEWER EASEMENT TAPPING TEE FIRE HYDRANT UNDERDRAIN GENERAL UTILITY NOTES 1. ALL WORK TO CONFORM TO STATE AND LOCAL REGULATIONS. 2. SITE GRADING SHALL NOT PROCEED UNTIL EROSION CONTROL MEASURES HAVE BEEN INSTALLED. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS (VERTICAL AND HORIZONTAL) IN THE FIELD PRIOR TO STARTING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF ANY DISCREPANCIES ARE FOUND IN THESE PLANS FROM THE ACTUAL FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 4 THE EXCAVATING CONTRACTOR MUST TAKE PARTICULAR CARE WHEN EXCAVATING IN AND AROUND EXISTING UTILITY LINES AND EQUIPMENT. VERIFY COVER REQUIREMENTS BY UTILITY CONTRACTOR'S AND /OR UTILITY COMPANIES SO AS NOT TO CAUSE DAMAGE. 5. THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES 72 HOURS BEFORE CONSTRUCTION IS TO START, TO VERIFY IF ANY UTILITIES ARE PRESENT ON SITE. ALL VERIFICATIONS (location, size and depth SHALL BE MADE BY THE APPROPRIATE UTILITY COMPANIES. WHEN EXCAVATING IS AROUND OR OVER EXISTING UTILITIES, THE CONTRACTOR MUST NOTIFY THE UTILITY COMPANY SO A REPRESENTATIVE OF THAT UTILITY COMPANY CAN BE PRESENT TO INSTRUCT AND OBSERVE DURING CONSTRUCTION. 6. TRENCHES FOR ALL STORM DRAIN LINES SHALL BE BACKFILLED COMPLETELY WITH SELECT GRANULAR MATERIAL IF WITHIN 5 FEET OF PAVEMENT. 7. AFTER STRIPPING TOPSOIL MATERIAL, PROOFROLL WITH A MEDIUM WEIGHT ROLLER TO DETERMINE LOCATIONS OF ANY POCKETS OF UNSUITABLE MATERIAL. THE NECESSITY FOR SUBDRAINS AND /OR REMOVAL OF ANY UNSUITABLE MATERIAL WITHIN THE PROPOSED PARKING AREAS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION. 8. PROVIDE POSITIVE DRAINAGE WITHOUT PONDING, IN ALL AREAS. AFTER INSTALLATION, CONTRACTOR TO TEST FOR, AND CORRECT, IF ANY, "BIRD BATH" CONDITIONS. 9. ALL PROPOSED SPOT ELEVATIONS ARE THE FINAL PAVEMENT AND FINAL GRADE ELEVATIONS. 10. SEE APPROPRIATE DETAILS TO DETERMINE SUBGRADE ELEVATIONS BELOW FINISH GRADE ELEVATIONS INDICATED. 11. ALL STORM SEWER MATERIALS AND INSTALLATION SHALL CONFORM TO LOCAL STANDARDS. 12. INVERTS AT PIPE OUTLETS ARE GIVEN AT END OF PIPE END SECTION. 13. WATER METERS SHALL BE INSTALLED INSIDE OF MECHANICAL ROOMS PER CITY OF CARMEL WATER STANDARDS. 14. ALL WATER MAINS SHALL BE DUCTILE IRON, CLASS 350. 15. CONTRACTOR IS RESPONSIBLE TO VERIFY DEPTH, SIZE AND LOCATION OF EXISTING WATER AND SEWER UTILITIES PRIOR TO CONSTRUCTION. 16. TRACER WIRE MUST BE INSTALLED WITH ALL WATER MAIN INDICATED ON PLAN. 17. WARNING TAPE MUST BE INSTALLED 12" TO 18" ABOVE ALL WATER MAIN INDICATED ON PLAN. CAUTION THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE including, but not limited to, manholes, inlets, valves, and marks made upon the ground by others AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. 1- 800 382 -5544 CALL TOLL FREE INDIANA UNDERGROUND BENCH INFORMATION BM 142 ELEV 884.62 (NAVD 88 DATUM) A U.S.C. G.S. BENCH MARK DISC SET IN A CONCRETE MONUMENT, 21' NORTH (NI 156 ST. ON EAST EDGE OF ABANDONED R.R. R /W, SOUTH OF WOODEN FENCE, 3' NORTHEAST OF 10' PINE TREE, WEST EDGE OF ASPHALT DRIVE. BM N237 ELEV 825.90 (NAVD 88 DATUM) A U.S.C. G.S. BENCH MARK DISC SET IN A CONCRETE MONUMENT, 21' WEST OF Q. CUMBERLAND ROAD, 28' SOUTH OF 146 STREET, STAMPED N237 1947. TBM 501 ELEV 836.66 A CHISELED "X" W. BONNET BOLT OF FIRE HYDRANT APPROX. 15' EAST OF EAST FACE OF KOHL'S 200' SOUTH OF SOUTHEAST CORNER OF KOHL'S TBM 50 ELEV 824.79 CUT "X" W. BOLT TRAFFIC STRAIN POLE AT THE NORTHWEST CORNER OF THE ENTRANCE TO LOWE'S 146 STREET RAMP. cc 0 (0 I- l a Z a CC o L Q NN CC cc W W Z F a W W o Z W F J O H z 4t 4 0 0•••4 g:4 a W Q 4 �4v e44 OA C3 W w1t1114u v, Fp =+`4 9700328 STATE OF 2 %SS/ON Al. I,t►1 CERTIFIED BY Z J 01. H J H W J otg csi 1:13 W Z I- .c o S T Ui O IL z 0 DATE: DRAWN BY: CHK'D BY: JOB NO. 05/20/04 WJT KMB IN2004.0443 REVISIONS e TAC REV. F I REV. FIRE HYD. LOC. A GENERAL 0 7/02/04 07/22/04 07/27/04 SHEET NO. C4.1 OF I N 2004.0443.073.C41.0 P