Loading...
HomeMy WebLinkAboutpg. 01 CoverA111-11EXANDIR Clubhouse 1411 FAIRFAX MANOR DR., CARMEL, INDIANA AREA MAP: CODE INFORMATION 1. INDIANA BUILDING CODE: 2003 EDITION, (2000 INTERNATIONAL BUILDING CODE AND ADDMENDMENTS) 2. USE GROUP: CLUBHOUSE; MIXED USE A3, B, ONE STORY 3. CONSTRUCTION TYPE: VB 4. AREA SEPARATION WALL: NONE, NOT REQUIRED 5. SPRINKLER SYSTEM: NONE, NOT REQUIRED 6. WIND LOAD DESIGN REQUIREMENT: 90 MPH, EXPOSURE 'B', 1.0 IMPORTANCE FACTOR 7. TOTAL BUILDING SQUARE FOOTAGE ALLOWED TYPE 5B UNPROTECTED CONSTRUCTION: BASIC ALLOWABLE 6,000 S.F. /FL. X 100% (100 -25 X 21 STREET FRONTAGE INCREASE 9,000 S.F. TOTAL ALLOWABLE TOTAL CLUBHOUSE S.F. 4,978 S.F. 8. ACCESSIBLE STRUCTURES: THE CLUBHOUSE SHALL BE ACCESSIBLE IN ACCORDANCE W/ INDIANA IBC CHAPTER 11 AND AMERICANS WITH DISABILITY ACT (ADA) DEVELOPER /OWNER: EDWARD ROSE DEVELOPMENT CO., L.L.C. 7901 CRAWFORDSVILLE ROAD P.O. BOX 24007 INDIANAPOLIS, INDIANA 46224 PHONE: (317) 297 -3060 No 3965 STATE OF /1/q4) C SITE MAP: MAIN STREET (131st Street) Fairfax Manor Drive 1 1 1111 1111111 111 h111J 1„1,I 111 HAM roam CLUBIIOU5r BUILDINGS ALEXANDRIA Cannel, Indiana Edward Rose Development Company, LLC November 27, 2006 ARCHITECT: MAS ASSOCIATES, L.L.C. Architects and Planners 5200 East 64TH Street, Suite A Indianapolis, Indiana 46220 msmith @masassociates.net Phone 317 726 106C Fax 317 726 1061 CERTIFICATION 08 CERTIFIED BY: DATE: GENERAL NOTES 1. CLUBHOUSE BUILDING (SEE CODE INFORMATION NOTE #8) IS REQUIRED TO BE ACCESSIBLE. DOORS, WINDOWS, EQUIPMENT, FIXTURES, HARDWARE AND DEVICES SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH THE NOTED CODE REQUIREMENTS. 2. ALL GLAZING IN HAZARDOUS LOCATIONS AS DEFINED BY IBC 2000 SECTION 2406.2 SHALL BE SAFETY GLAZING. 3. CLUBHOUSE INTERIOR FINISH MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF ASTM CLASS III (76 -200). SMOKE DEVELOPMENT RATINGS SHALL NOT EXCEED REQUIREMENTS FOR B OCCUPANCY IBC 2000 TABLE 803.4 4. ALL GLAZING AND HARDWARE INSTALLED ON FIRE —RATED DOORS SHALL COMPLY WITH IBC 714.2.6.4 5. ALL LOCKS AND LATCHES INSTALLED ON EGRESS DOORS SHALL COMPLY WITH IBC 1003.3.1.8 6. THERMAL AND SOUND INSULATING MATERIALS AND COVERING ON PIPES AND TUBING SHALL HAVE A SMOKE— DEVELOPED RATING, EXCEPT WHEN CONCEALED IN CONSTRUCTION SHALL BE 75 OR LESS.OF 450 OR LESS. FLAME SPREAD RATING OF THESE MATERIALS SHALL NOT EXCEED 25. LATEST REVISIONS FOR CONSTRUCTION DRAWINGS DATE: fL CS SHEET INDEX SHEET SHEET DESCRIPTION CS COVER SHEET CS101 CLUBHOUSE FOUNDATION PLAN CS102 CLUBHOUSE ROOF FRAMING PLAN CS201 FOUNDATION DETAILS CS301 CLUBHOUSE SHEARWALLS CA101 CLUBHOUSE FLOOR PLAN CA102 CLUBHOUSE ROOF PLAN CA103 CLUBHOUSE FLOOR FINISH CA201 CLUBHOUSE ELEVATIONS CA202 CLUBHOUSE ELEVATIONS CA301 CLUBHOUSE BUILDING SECTIONS CA401 WALL SECTIONS CA402 WALL SECTIONS CA403 WALL SECTIONS CA404 WALL SECTIONS CA405 WALL SECTIONS CA501 DETAILS CA601 DOOR, FRAME, WINDOW ROOM FINISH SCHEDULE AND DETAILS CA701 INTERIOR ELEVATIONS CE101 CLUBHOUSE ELECTRICAL FLOOR PLAN CM101 CLUBHOUSE MECHANICAL FLOOR PLAN CP101 CLUBHOUSE PLUMBING FLOOR PLAN A111-11EXANDIR Clubhouse 1411 FAIRFAX MANOR DR., CARMEL, INDIANA AREA MAP: CODE INFORMATION 1. INDIANA BUILDING CODE: 2003 EDITION, (2000 INTERNATIONAL BUILDING CODE AND ADDMENDMENTS) 2. USE GROUP: CLUBHOUSE; MIXED USE A3, B, ONE STORY 3. CONSTRUCTION TYPE: VB 4. AREA SEPARATION WALL: NONE, NOT REQUIRED 5. SPRINKLER SYSTEM: NONE, NOT REQUIRED 6. WIND LOAD DESIGN REQUIREMENT: 90 MPH, EXPOSURE 'B', 1.0 IMPORTANCE FACTOR 7. TOTAL BUILDING SQUARE FOOTAGE ALLOWED TYPE 5B UNPROTECTED CONSTRUCTION: BASIC ALLOWABLE 6,000 S.F. /FL. X 100% (100 -25 X 21 STREET FRONTAGE INCREASE 9,000 S.F. TOTAL ALLOWABLE TOTAL CLUBHOUSE S.F. 4,978 S.F. 8. ACCESSIBLE STRUCTURES: THE CLUBHOUSE SHALL BE ACCESSIBLE IN ACCORDANCE W/ INDIANA IBC CHAPTER 11 AND AMERICANS WITH DISABILITY ACT (ADA) DEVELOPER /OWNER: EDWARD ROSE DEVELOPMENT CO., L.L.C. 7901 CRAWFORDSVILLE ROAD P.O. BOX 24007 INDIANAPOLIS, INDIANA 46224 PHONE: (317) 297 -3060 No 3965 STATE OF /1/q4) C SITE MAP: MAIN STREET (131st Street) Fairfax Manor Drive 1 1 1111 1111111 111 h111J 1„1,I 111 HAM roam CLUBIIOU5r BUILDINGS ALEXANDRIA Cannel, Indiana Edward Rose Development Company, LLC November 27, 2006 ARCHITECT: MAS ASSOCIATES, L.L.C. Architects and Planners 5200 East 64TH Street, Suite A Indianapolis, Indiana 46220 msmith @masassociates.net Phone 317 726 106C Fax 317 726 1061 CERTIFICATION 08 CERTIFIED BY: DATE: GENERAL NOTES 1. CLUBHOUSE BUILDING (SEE CODE INFORMATION NOTE #8) IS REQUIRED TO BE ACCESSIBLE. DOORS, WINDOWS, EQUIPMENT, FIXTURES, HARDWARE AND DEVICES SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH THE NOTED CODE REQUIREMENTS. 2. ALL GLAZING IN HAZARDOUS LOCATIONS AS DEFINED BY IBC 2000 SECTION 2406.2 SHALL BE SAFETY GLAZING. 3. CLUBHOUSE INTERIOR FINISH MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF ASTM CLASS III (76 -200). SMOKE DEVELOPMENT RATINGS SHALL NOT EXCEED REQUIREMENTS FOR B OCCUPANCY IBC 2000 TABLE 803.4 4. ALL GLAZING AND HARDWARE INSTALLED ON FIRE —RATED DOORS SHALL COMPLY WITH IBC 714.2.6.4 5. ALL LOCKS AND LATCHES INSTALLED ON EGRESS DOORS SHALL COMPLY WITH IBC 1003.3.1.8 6. THERMAL AND SOUND INSULATING MATERIALS AND COVERING ON PIPES AND TUBING SHALL HAVE A SMOKE— DEVELOPED RATING, EXCEPT WHEN CONCEALED IN CONSTRUCTION SHALL BE 75 OR LESS.OF 450 OR LESS. FLAME SPREAD RATING OF THESE MATERIALS SHALL NOT EXCEED 25. LATEST REVISIONS FOR CONSTRUCTION DRAWINGS DATE: fL CS