HomeMy WebLinkAbout22 C602 Storm Sewer Plan\ID SECTION 132 a W O J Z II D 19.10 I— W o 0 O II m CV Z 0 0 0 E GUARD II I Z .C.= 920.80 B INLET 136 w/P 56'616= II U CU z W CU z 0 0 EXISTING GRADE a, Z Z 0 0 CONC. Et DESIGN APPROVAL 15 6 8 Yes 18" to 21" 112 L.F. 0.30% 12» R.C.P. Q PROPOSED GRADE EXISTING GRADE 15.78 16.12 Yes CU T.C. STREET B CCU FULL DEPTH GRANULAR BACKFILL W U z Z U -Sva /M 0.30% 12" R.C.P. No Yes 117 L.F. 0.20% 30" R.C.P. 191 L.F. 0.20% 30" R.C.P. Yes 136 L.F. 0.20% 27" R.C.P. 54 L.F. DESIGN APPROVAL —A. 1) No Yes 24" or LARGER 15.59 15.89 0.30% 15.89 16.05 16.19 6.05 122 L.F. 0.45% 16.19 24" R.C,P. 16.74 15.00 15.21 L� 15.21 15.5• 27 R.C.P. 0 L.F. INV 915.21 R.C.P. E. INV .=915.21 0.45% r4" R.C.P 12" R.C.P. E. INV.= 916.19 'D INLET 133 a W O J Z II D 19.10 1 I VZi7 L TIOF O L'6 l m CV Z 0 0 0 E GUARD U U _i co a FULL DEPTH PROPOSED GRADE GRANULAR BACKFILL T.C. =9 STREET F 1 INVVI 6 II U CU z W CU z 0 0 EXISTING GRADE w/ TRASH R.C.P. SW. R.C.P. NW. 915.21 iiii 150 L.F. .0:28% 18" R.C.P. DESIGN APPROVAL 15 6 8 Yes 18" to 21" 112 L.F. 0.30% 12» R.C.P. 15.69 15.63 15.63 15.21 15.78 16.12 Yes 32 L.F 30 L.F. 24 "x36" 0.20% 18" R.C.P 0.30% 12" R.C.P. No Yes PIPE SIZE STRUCTURES LESS THAN 48" FROM T/C TO INVERT STRUCTURES GREATER THAN 48" FROM T/C TO INVERT ANGLE AND QUALITY OF PIPES WILL REQUIRE SPECIAL DESIGN STEPS REQUIRED CURB CASTING *R -3501 N CASTING *3501 TL TR 12" to 18" 24 "x24" DESIGN APPROVAL No Yes Yes 12" to 21" 30 "x30" DESIGN APPROVAL No Yes Yes 18" to 21" MH /BOX DESIGN APPROVAL Yes Yes Yes 21" to 27" 24 "x36" DESIGN APPROVAL No No Yes 12" to 24" 36"x36" DESIGN APPROVAL No Yes Yes 24" OR LARGER DESIGN APPROVAL DESIGN APPROVAL No No Yes 24" or LARGER MH /BOX DESIGN APPROVAL Yes Yes Yes LET 137 w /MH a I— W z i m 0) c i 0) D ;URB INLET 139 55'OZ6 ='0'. co 01—: FULL DEPTH GRANULAR BACKFILL II U PROPOSED EXISTING GRADE GRADE 0 FULL DEPTH r— GRANULAR BACKFILL 8" R.C.P. S. 2" R.C.P. N. VV.= 916.19 j 16.19 115 L.F. 0.45% 12" R.C.P. 16.71 16.80 16.71 30 L.F. 0.30% 12" R.C.P 18 N N 19 APPROXIMATE LOCATION OF THE STULTZ ALMOND LEGAL DRAIN EASEMENT (75' ON BOTH SIDES OF THE FIELD TILE) AS SCALED FROM COUNTY SURVEYOR'S LEGAL DRAIN MAPS (WILL BE CRUSHED OR ABANDONED CROSS THE TRAILS HAYDEN RUN SITE PER APPROVED METHODS BY THE CITY OF CARMEL ENGINEER) 20 N N 21 N T i 22 23 24 920 910 920 910 SCALE: 1"=50' H OR. 1"=5' VERT. SCALE: 1"= 50' 920 30" 30" INV 910 PIPES NO LARGER THAN 18" CAN BE USED IN THE 2' SIDE OF THIS BOX INCOMING AND OUT GOING PIPES EFFECT STEPS IN THIS STRUCTURE SCALE: NOTE: CONSTRUCTION TOLERANCE FOR YARD INLETS WILL BE +0.0' TO —0.20' NOTE: "EXCEPT FOR FORCE MAINS, CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES AND STORM SEWERS IS 18" OR LESS." ALL MANHOLES TO BE CONSTRUCTED WITH ONE 4" RISER RING TO ESTABLISH PLAN CASTING GRADE. ALL CURB INLET CASTINGS TO BE NEENAH R- 3501 —L2 ALL EXISTING OFF —SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW 1"=50' HOR. 1"=5' VERT. %%0,0011 1111111 '�1STEA�c �F� No Z= 19358 STATE OF ONAL EN i �r rrnr� uN� SCALE: 1"=50' HOR. 1"=5' VERT. CURB INLET TABLE SPECIAL NOTE STRUCTURES DEEPER THAN 48" FROM T/C TO INVERT WILL BE A M.H. OR A BOX WITH STEPS UNLESS SPECIAL DESIGN IS APPROVED. SPECIAL NOTE STRUCTURES WILL BE DESIGNED FOR MAXIMUM FLOW IN PIPES SPECIAL NOTE: COUNTY MAY REQUIRE STEPS TO BE INSTALLED AFTER STRUCTURE IS SET, TO IMPROVE ACCESS. Q 3 m w O a_ c).3 a_ z w (I) F- w O m LL W 0 W 0 J u 1 6 II JOB Na 45370EQU m W I- 0 0 LL 1= W U N- DC W L z z Lid 0 a z J W 2 H z W U SHEET NO. C602 LAND SURVEYORS CONSULTING ENGINEERS REVISIONS