HomeMy WebLinkAboutC600 Storm Plan & ProfilesYARD INLET 15 IJ O O 0 r�i z �I PROPOSED GRADE 6 STA.1 +10 T. C. 915. DBL. CURB STA.1 +51 T.C.= 914.60 WINDY KNOLL DBL. CUF] I- J ct Z o Q �Q FULL DEPTH Q GRANULAR BACKFILL O I- O O J zc0� r °j EXISTING GRADE o l c i 0 0 C�1 0 Z W u I i- w c(.m—: z 0 U 69 +L'V ±S 162 L.F. 0.60% 12" R.C.P. •1 s. 25 L. F. 0.30% 15" R.C.P. 41 L. F.< Yes 41 LF.:.: 159 L.F. 0.30% 21" R.C.P. GRANULAR BACKFILL 242 L.F. 0.97% 15" R.C.P 207 L.F. 0.30% 27" R.C.P. Yes 212 L.F. 0.30% 27" R.C.P. 911.86 11.48 0.30% 911.24 0.30% ilii 1.7 Awe 8" SDR -35 P.V.C. INV.= 909.20 91012 y09.50 21" to 27" 15" R.C.P.— 18" R.C.P. cjj No Yes 12" to 24" 6" WATER DESIGN APPROVAL YARD INLET [Y 0 a.) PROPOSED GRADE II U CV U J Q ov) ANGLE AND QUALITY OF PIPES WILL REQUIRE SPECIAL DESIGN DBL. CUF] 0 O) w II Q cv w cn EXISTING GRADE cc L +t*vis 12" to 18" z o 162 L.F. 0.60% 12" R.C.P. •1 s. No 3 0.60% i CONCRETE CRADLE Yes 12" to 21" FULL DEPTH DESIGN APPROVAL GRANULAR BACKFILL 242 L.F. 0.97% 15" R.C.P Yes Yes 911.84 MH /BOX 6" WATER 1.7 Awe 8" SDR -35 P.V.C. INV.= 909.20 PIPE SIZE STRUCTURES LESS THAN 48" FROM T/C TO INVERT STRUCTURES GREATER THAN 48" FROM T/C TO INVERT ANGLE AND QUALITY OF PIPES WILL REQUIRE SPECIAL DESIGN STEPS REQUIRED CURB CASTING *R -3501 N CASTING *3501 TL TR 12" to 18" 24 "x24" DESIGN APPROVAL No Yes Yes 12" to 21" 30 "x30" DESIGN APPROVAL No Yes Yes 18" to 21" MH /BOX DESIGN APPROVAL Yes Yes Yes 21" to 27" 24 "x36" DESIGN APPROVAL No No Yes 12" to 24" 36 "x36" DESIGN APPROVAL No Yes Yes 24" OR LARGER DESIGN APPROVAL DESIGN APPROVAL No No Yes 24" or LARGER MH BOX DESIGN APPROVAL Yes Yes Yes i I i 920 910 920 910 N PIPES NO LARGER THAN 18" CAN BE USED IN THE 2 SIDE OF THIS BOX INCOMING AND OUT GOING PIPES EFFECT STEPS IN THIS STRUCTURE CURB INLET TABLE J SCALE: z O m o SPECIAL NOTES STRUCTURES DEEPER THAN 48" FROM T/C TO INVERT WILL BE A M.H. OR A BOX WITH STEPS UNLESS SPECIAL DESIGN IS APPROVED. SPECIAL NOTE STRUCTURES WILL BE DESIGNED FOR MAXIMUM FLOW IN PIPES SPECIAL NOTE. COUNTY MAY REQUIRE STEPS TO BE INSTALLED AFTER STRUCTURE IS SET, TO IMPROVE ACCESS. 1"=50' HOR. 1 =5' VERT. SCALE: 1"=50' HOR. 1"=5' VERT. NOTE: CONSTRUCTION TOLERANCE FOR YARD INLETS WILL BE +0.0' TO -0.20' NOTE: "EXCEPT FOR FORCE MAINS, CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES AND STORM SEWERS IS 18" OR LESS." ALL MANHOLES TO BE CONSTRUCTED WITH ONE 4" RISER RING TO ESTABLISH PLAN CASTING GRADE. ALL CURB INLET CASTINGS TO BE NEENAH R- 3501 -N EXCEPT FOR DOUBLE INLETS, THEY WILL BE NEENAH R -3501 -TR,TL ALL EXISTING OFF -SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW SCALE: 1 50' /ij ��.•�`�j STOEPp,. No. 19358 -o STATE OF -61 9/0 N A 1 0 ,00' 11 oo z O I- U W U) r m s m m L LiJ UJ O J 0 II I Li F- JOB NO. 42480 0 Z Z W 0 >--r) iz 0 <0 Li 0 Z H m 0 z 0 Z U) 0' w U) U- Q z z LU U SHEET NO. C600 CONSULTING ENGINEERS LAND SURVEYORS REVISIONS REVISED PER TAC COMMENTS SECTION 144