Loading...
HomeMy WebLinkAboutC601 Storm Plan & ProfilesCONCRETE END 01/4-' ��H 0 0 Q ii P GRADE -N 0� T.C. WINDY KN STA.5 +4S N II 0.11 (pH: 0 EXISTING GRADE Li W L� Cr 0 z o L L +L'VIS Z 0 0 FULL DEPTH FULL DEPTH 90 L.F. 157 L.F. 0.30% 15" R.C.P. 36 L.F. GRANULAR BACKFILL 127 L.F. 0.30% 21" R.C.P. 300 L.F. 0.29% 24" R.C.P. 0.19% 91O.i1.o Ir 0.30% 911.73 910.777 0 s11.o�9i T18" R.C.P... 1i.4 12" R.C.P. I %1;.14 R.C.P. 910.47 S EX. 12" WATER V TOP= 907.5± t5.BL 18" R.C.P" 0 8" SDR -35 P.V.C. INV.= 906.55 No 00 21" R.C.P. INV. 910.47 E 0 0 12" to 24" CONCRETE END 1— 0 0 O Cpl EXISTING GRADE _j <:e o col— DBL. CURB H N• o LLI F LLI N II PROPOSED GRADE H Q Lj W H O (n P- o STA.5 +4S H 0 U) Z 0 0 GRANULAR BACKFILL I 150 L.F. 0.20% 21" R.C.P FULL DEPTH 32 31 L.F. 149 L.F. 0.20% 15" R.C.P. 251 L.F. 0.20% 18" R.C.P. DESIGN APPROVAL GRANULAR BACKFILL 266 L.F. 0.20% 18" R.C.P. 0.19% 91O.i1.o R.C.P. 910.37 NW 910.777 MH /BOX 0.19% wait) Yes R.C.P. 910.47 S EX. 12" WATER V TOP= 907.5± t5.BL 18" R.C.P" 0 8" SDR -35 P.V.C. INV.= 906.55 G i V) `r L11 QU V) I-: EXISTING GRADE FULL DEPTH co t ix Q c.) T.C. OLIVER LAIN STEPS REQUIRED MII Q (-5 w 1- 011 iQ PROPOSED GRADE 0 O' o H Q =•O'1 I'V'S I GRANULAR BACKFILL I 150 L.F. 0.20% 21" R.C.P :r. 32 L.F. imar a1 149 L.F. 0.20% 15" R.C.P. 186 L.F. 0.20% 12" R.C.P. DESIGN APPROVAL No 0.19% 91O.i1.o R.C.P. 910.37 NW 910.777 MH /BOX 8" SDR -35 P.V.C. 0 INV.= 904.10 18" R.C. Yes Yes R.C.P. 910.47 S EX. 12" WATER TOP 909.7± PIPE SIZE STRUCTURES LESS THAN 48" FROM T/C TO INVERT STRUCTURES GREATER THAN 48" FROM T/C TO INVERT ANGLE AND QUAUTY OF PIPES WILL REQUIRE SPECIAL DESIGN STEPS REQUIRED CURB CASTING *R -3501 N CASTING *3501 TL TR 12" to 18" 24 "x24" DESIGN APPROVAL No Yes Yes 12" to 21" 30 "x30" DESIGN APPROVAL No Yes Yes 18" to 21" MH /BOX DESIGN APPROVAL Yes Yes Yes 21" to 27" 24x36 DESIGN APPROVAL No No Yes 12" to 24" 36 "x36" DESIGN APPROVAL No Yes Yes 24" OR LARGER DESIGN APPROVAL DESIGN APPROVAL No No Yes or 2A" RG AE LARGER L MH /BOX DESIGN APPROVAL Yes Yes Yes 920 910 920 910 0 0 CD Et Z� o� H 21" INV. 12" INV. PIPES NO LARGER THAN 18" CAN BE USED IN THE 2' SIDE OF THIS BOX INCOMING AND OUT GOING PIPES EFFECT STEPS IN THIS STRUCTURE C\10 moo, Q Z o I- I U U1 UJ co Lc) H O LI in Ln Z CURB INLET TABLE I- 0 J Z�� SPECIAL NOTE STRUCTURES DEEPER THAN 48" FROM T/C TO INVERT WILL BE A M.H. OR A BOX WITH STEPS UNLESS SPECIAL DESIGN IS APPROVED. SPECIAL NOTE STRUCTURES WILL BE DESIGNED FOR MAXIMUM FLOW IN PIPES SPECIAL NOTE COUNTY MAY REQUIRE STEPS TO BE INSTALLED AFTER STRUCTURE IS SET, TO IMPROVE ACCESS. SCALE: 1"=50' HOR. 1"=5' VERT. SCALE: 1"=50' HOR. 1 =5' VERT. H 1.I SCALE: 1 =50' HOR. o 1 =5' VERT. 2 1 °L6 NOTE: CONSTRUCTION TOLERANCE FOR YARD INLETS WILL BE +0.0' TO —0.20' NOTE: "EXCEPT FOR FORCE MAINS, CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES AND STORM SEWERS IS 18" OR LESS." ALL MANHOLES TO BE CONSTRUCTED WITH ONE 4" RISER RING TO ESTABLISH PLAN CASTING GRADE. ALL CURB INLET CASTINGS TO BE NEENAH R- 3501 —N EXCEPT FOR DOUBLE INLETS, THEY WILL BE NEENAH R- 3501 —TR,TL ALL EXISTING OFF —SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW CD H O Li 0 J O Z 920 910 _„'I I I I I I IIII, 5TO EPp Tl No. Z 19358 -o STATE OF j Q SCALE: 1" 50' LO Z 0 H 0 Lv r m s co co L_ LU v LU X LL m w H 0 0 CO z 0 Z w W J G": O c•43 Z J O H z Ct z w >-ro 0 o a U w W O W 2 H z 0 z LU U SOB NO. 42480 SA42480s3\dwg\C601-Storm Plan Profile.dwg, Layout1, 6/1/2004 12:25:31 PM, Noy, 1:1 CONSULTING ENGINEERS LAND SURVEYORS REVISIONS