Loading...
HomeMy WebLinkAbout03100012 Runyon Equipment Rental, Site & Utility Plan Design AlternateJACK'S TOOL RENTAL SITE 410 West Carmel Drive Carmel, Indiana I til l i I l 1111 ......40 ti?'..., No. 19900113 STATE OF 1? 4 IND I All s k ,i, ONAL etd a/Ailtiss."" October 6th, 2003 Approved By: D. Scott Bordenet Drawn By: TJW Date of Last Field Work: Sit e/Utility Plan Design Alternate Benchmark Surveying, Inc. 9855 Crosspoint Blvd., Suite 110 Indianapolis, IN 46256 Ph. 317 -841 -1506 Fax 317 -841 -1507 benchmarkls.com Project Description: 1. The contractor shall comply with all pertinent provisions of the Manual of Accident Prevention in Construction issued by AGC of America and the Safety and Health Regulations of Construction issued by the U.S. Department of Labor. 2. The contractor shall be responsible for locating all existing utilities prior to commencement of work. The contractor shall contact the utilities company at least 72 hours prior to commencement of work. 3. When necessary for completion of new construction, the contractor shall repair any damage to existing features (i.e. paving, utilities, drainage, etc.), which are to remain at no additional cost to the owner. 4. The contractor shall make field adjustments as necessary to provide a smooth vertical and horizontal transition between existing and proposed pavements. 5. All site concrete shall be INDOT Class A 3500 PSI concrete unless otherwise stated on the plans. 6. All site construction, materials, and features (i.e. curbs, walks, paving, concrete, storm drainage features, seeding, sodding, earthwork, etc.) shall be in accordance with all city and state standards and specifications. 7. Concrete walks, paving, and curbs shall have a medium broom finish unless otherwise specified on the architectural plans. 8. The contractor shall conform to all applicable codes and regulations and receive all required permits necessary to construction. 9. The contractor shall field verify dimensions before ordering material. Any discrepancies shall be reported to the owner or his representative and resolved prior to the commencement of work. 10. Roadway dimensions are to face of curb unless otherwise specified. Owner Developer: iiii lk i der TOOL RENTAL INC CA RNt E l 317 691 7 Revi Date Remarks 1 7/15/03 Revised Per Client Request 2 7/21/03 Added Heavy Duty Pavement 3 7/23/03 Added Proposed R/W Dimension TAC Comments 4 09/05/03 Revised Per City Engineer 2nd 5 10/6/03 Parking Expansion w/ Storm Sewer Imp. Project 3 -248 [Jack Tool Rental] Sheet No. 3A of SYMBOL LEGEND WATER VALVE O STORM SEWER MANHOLE iiiii CURB INLET OIL SEPARATOR SHALL MEET- CARMEL UT1LUTIE? SPECIFICATIONS T.C.= B328I3 CONfiRACTOR TO UNCOVER AND.:VERIFI EXISTING .SANITARY LATERAL LOCA11ON A CONDITION.; ,r'"V1 I1E. INTO' EXISTING: SANITARY' LATERAL' 4T APPROXIMATE OCAT10N SHOWN it P e n t BOX TYPE AND LOCA11ON TO BE COORDINATED BETWEEN OWNER, CONTRACTOR AND CARMEL FIRE DEPT. CASTING TYPE M `INLET Wl 3287 -10V CASTI .LED PARKING CURB ALONDEAST- i" PARKING EXTERIOR BENDS AS _.NECESSARY_ RE -USE EXIST. GAS METER IF PLAUSIBLE RE -USE EXIST. ELECTRIC METER IF PLAUSIBLE HATCHED AREA DENOTES PROPOSED RIGHT OF -WAY DEDICA11ON TO THE CITY OF CARMEL. P.O.B. of the Surveyed Tract 1 �l do =AS GAS GAS GAS GAS GAS IPA cv 1 Speed Sign '(cufTrrc 1, Pee :3e ck =ndc] �iook 343, Page 748 PROPOSED EDGE OF PAVEME ENTRANCE PER CITY OF CARMEL NOTE: SEE SHEET 11A FOR DETAILS OF ALL ALTERNATE IMPROVEMENTS onduit r Curve Data l Sanitary Se Manhole T.O.C. Elev.829.79 W. 8" Clay /Inv. El 820.86 l N. 15" Clafy Inv. Elev.= 8 20.28 S. 15" Cl y Inv. Elev.= 820.24 i f 1 l 1, j V`\ C� i..,-- term praingge Inlet: I i 4 C. Etv .54 �gAM Sanitary Sewer Manhafe� W. 10" Clay Inv. Elev. 820` 5 sA TBM #2 Elev. =830. 7 R 425.00' Curve Length Sanitary ewer Manhole T.O.C. E,l''v.= 830.72 ---N.,15"/ Inv. Elev.= 820.48 ,T�-- S>`I Clay Inv. Elev. 820.57/ /AD FIRE HYDRANT O SANITARY MANHOLE TREE CATCH BASIN TELEPHONE PEDESTAL T LIGHT POLE 0 SIGN 0 IRON PIN GAS VALVE GAS MARKER UGE UNDERGROUND UGE ELECTRIC UGT UNDERGROUND UGT TELEPH SAN SANITARY SEWER SAN 0.. FLOWUNE GAS GAS LINE GAS STM STORM SEWER STM WTR WATER LINE WTR RIGHT -OF -WAY 1 PROPOSED FEATURE 1 EXISTING FEATURE NOTE TO CONTRACTOR: A GEOMETRIC SHEET EXISTS FOR THIS PROJECT. PLEASE COORDINATE WITH THE DEVELOPER AT TIME OF CONSTRUCTION. DESIGN INFORMATION BUILDINGS: One (1) Office Buildings 8,482s.f. MIN. SIDE YARD SETBACKS: None MIN. FRONT YARD SETBACKS: 15' MIN. REAR YARD SETBACKS: 15' MAX. BLDG. HEIGHT: 60' LOT ACREAGE: Lot 1.591Ac.± PARKING: 39 SPACES TOTAL 2 ACCESSIBLE NOTE: THESE CONSTRUCTION PLANS CONTAIN INFORMATION SUPPLIED TO BENCHMARK BY CROSSROADS ENGINEERING FOR THE PURPOSE OF SHOWING FUTURE RIGHT —OF —WAY AND INTERSECTION IMPROVEMENTS FOR THE ROAD, STORM SEWER AND SIGNALIZATION PROPOSED BY THE CITY OF CARMEL. THIS INFORMATION WAS DEEMED CURRENT AT THE TIME OF FILING. NOTE: HATCHED AREA DENOTES AREA PROPOSED BY THE CITY OF CARMEL FOR FUTURE RIGHT —OF —WAY ALONG SW 3RD AND CARMEL DRIVE. GRAPHIC SCALE 20 0 10 20 40 IN FEET 1 inch 20 ft. Site Details (STE: Sht, 7 &11) Sidewalk Details RD Ramp Details— MD Masonry Dumpster Details CC Combined Curb and Walk Details Depressed Curb SP Standard Paving Sectio HP Heavy Duty Paving Section BD Pipe Bollard Details DF Decorative Fence Detail O Handicap Parking Details— Sanitary Sewer Details (SAN: Sht. 11) CE Concrete Encasement Details Cleanout Details SL Service Lateral Details- Concrete Cradle Details Boring Details Sanitary Storm Sewer Details (STM: Sht. 12) Structure with Casting Concrete Pipe Water Utility Details (WUT: Sht. 11) Water Valve Details Thrust Block Details Water Meter Details Tapping Sleeve a Fire Hydrant Water Crossing Details Boring Details Water Pipe Backfill Details (PE: Sht. 14) Pipe Backfill Details O Curb Turnout Typical Swale Erosion Control Details (ECD: Sht. 9) RR Riprap IP Inlet Protection Stable Construction Entrance SF Silt Fence Landscaping Details (LD: Sht. 6) Shrub Planting Details Coniferous Tree Planting Details DT Deciduous Tree Planting Details