Loading...
HomeMy WebLinkAboutpg. 14 C601 Storm Sewer Plan & ProfileDBL. CUR: STRUCTURES LESS THAN 48" FROM T/C TO INVERT CURB INLE1 m co c\l II 1- U H z 0 m FULL DEPTH Q II 00'016 ='0' CURB CASTING *R -3501 N CASTING *3501 TL TR 12" to 18" 24 "x24" GRANULAR BACKFILL PROPOSED GRADE EXISTING GRADE DESIGN APPROVAL No 12" 30 L.F. 1.00% R.C.'. X 8.30 0 8 1% 15" R.C.P. HYDRAULIC GRADE LINE 06.77 21" R.C.P. 27" R.C.P. INV. =906.7 DESIGN APPROVAL No Yes Yes 18" to 21" PIPE SIZE STRUCTURES LESS THAN 48" FROM T/C TO INVERT STRUCTURES GREATER THAN 48 FROM T/C TO INVERT ANGLE AND QUAUTY OF PIPES WILL REQUIRE SPECIAL DESIGN STEPS REQUIRED CURB CASTING *R -3501 N CASTING *3501 TL TR 12" to 18" 24 "x24" DESIGN APPROVAL No Yes Yes 12" to 21" 30 "x30" DESIGN APPROVAL No Yes Yes 18" to 21" MH /BOX DESIGN APPROVAL Yes Yes Yes 21" to 27" 24 "x36" DESIGN APPROVAL No No Yes 12" to 24" 36 "x36" DESIGN APPROVAL No Yes Yes 24" OR LARGER DESIGN APPROVAL DESIGN APPROVAL No No Yes 24" or LARGER MH /BOX DESIGN APPROVAL Yes Yes Yes 920 910 1 1 0 0 J I� CO 00 Cr z:= te r? Q 00) 11 J 11 U o Q� o� 09.27 125 148 L.F. 0.40% 15" R.C.P. 08.68 0) co 36 L.F. 0.40% 18" R.C. 08.68 08.53 08.53 FULL DEPTH GRANULAR BACKFILL 440 L.F. HYDRAULIC GRADE LINE 136 PROPOSED GRADE 0.110% 137 SCALE: 1"=50' HOR. 1"=5' VERT. 21" R.C.P. i i 138 EXISTING GRADE 06.77 I- 0 w0 _J z II U Q�. 139 06.77 279 L.F. 15" R.C.P. S. INV.= 906.77 140 0.20% 27" R.C.P. LAKE #6 N.P 906.00 2 YEAR ELEV.= 907.60 10 YEAR ELEV.=-909.22 100 YEAR ELEV. 911.25 BOTTOM ELEV.= 898.00 FULL DEPTH GRANULAR BACKFILL 06.21 00 00 F- W -J z U C.A. Q J L.0 z I- U 06.21 06.15 30 L.F. 0.20% 27" R.C.' 0 L. 0 06.15 6.0 30" R.C.P. 00 U z 0 U 920 910 (N1 0) LJ J z 0 SCALE: 1"=50' HOR. 1"=5' VERT. CURB INLET TABLE W. SE. 7 PIPES NO LARGER THAN 18" CAN BE USED IN THE 2' SIDE OF THIS BOX INCOMING AND OUT GOING PIPES EFFECT STEPS IN THIS STRUCTURE SPECIAL NOTE: STRUCTURES DEEPER THAN 48" FROM T/C TO INVERT WILL BE A M.H. OR A BOX WITH STEPS UNLESS SPECIAL DESIGN IS APPROVED. SPECIAL NOTE: STRUCTURES WILL BE DESIGNED FOR MAXIMUM FLOW IN PIPES SPECIAL NOTE COUNTY MAY REQUIRE STEPS TO BE INSTALLED AFTER STRUCTURE IS SET, TO IMPROVE ACCESS. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE— DRAINS TO WATERWAY" NOTE: CONSTRUCTION TOLERANCE FOR YARD INLETS WILL BE +0.0' TO —0.20' NOTE: "EXCEPT FOR FORCE MAINS, CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWER FACILITIES AND STORM SEWERS IS 18" OR LESS." ALL MANHOLES TO BE CONSTRUCTED WITH ONE 4" RISER RING TO ESTABLISH PLAN CASTING GRADE. SCALE: 1"= 50' ALL EXISTING OFF —SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW STOEPp Q/ No. s.: r. 19358 -53 -o STATE OF '2: 6 iNDIANP ',,,►l I` t'tt' ALL CURB INLET CASTINGS TO BE NEENAH R- 3501 —L2 UNLESS A DOUBLE INLET CASTING IS SPECIFIED. IN THIS CASE A NEENAH R- 3501 —TR&TL ARE TO BE USED. NOTE: THERE SHALL BE A 12" MIN. COVER FROM TOP OF PIPE TO BOTTOM OF PAVEMENT ON ALL STREET PIPE CROSSINGS. W J Li ck3 O Z J W W O CO LiJ 0 W N) Q 0 J Ln 0 II 0 N LL w U Q cr o z_ O LL Z o I= U UJ 0 L�J 0 V W ul U SHEET NO. C6O1 JOB No.41760S4 m w 1- Q 0 W N z 0 z CC W SA41760S4\dwg\C601-Storm Plan Profile.dwg, Layout1, 8/26/2004 1:30:47 PM, Noy, 1:1 CONSULTING ENGINEERS LAND SURVEYORS REVISED PER TAC COMMENTS OUR SEASONS END SECTION REVISIONS