Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
pg. 16 C800 Construction Details
Pipe Diameter In. Minimum Time, mints Length for Minimum Time ft Time for Longer Len: S Specification Time for Length (L) Shown, mints 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5:40 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 25:38 32:03 26:27 44:52 51:16 57:41 21 19:50 114 10.470 L 18:60 26:10 34:54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 124:38 142:25 Kam 193:53 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129:18 150:43 172:21 38 34:00 86 30.788 L 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 1. Standard specifications of the Clay Township Regional Waste District (District) and Indiana Department of Transportation shall apply for all work and materials. Pipe shall be installed in accordance with Section 715 of the latest edition of the Indiana Department of Transportation Standard Specifications. 2. Sanitary sewer pipe shall be PVC in accordance with ASTM D -3034 (S.D.R. 35) and ASTM 2321. PVC pipe shall have a grooved bell and gasket, The pipe shall be made of PVC plastic having a cell classification of 12454B.. 3. PVC sewer fittings shall conform to the requirements of ASTM D- 3034 -89 specification. Fittings in sizes through 8" shall be molded in one piece with elastomeric joints and minimum socket depths as specified in sections 6.2 and 7.3.2. Fittings 10" and larger shall be molded or fabricated in accordance with section 7.11 with manufacturers standard pipe bells and gaskets. Wall thickness of fittings shall be SDR 26 as defined in section 7.4.1 of specifications. Gaskets for elastomeric joints shall be molded with a minimum cross sectional area of 0.20 square inches and conform to ASTM F -477 specification. 4. All sanitary manholes shall be Aprecast concrete@ manholes in accordance with ASTM C -478 and Section 720. 0 -rings shall conform to C -443. Kent Seal or equivalent shall also be applied to all joints and between riser rings and castings. Manhole step spacing shall be no more than 16- inches. Manholes shall be air tested for leakage in accordance with ASTM C1244 -93, Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test. A Installation and operation of vacuum equipment and indicating devices must be in accordance with manufacturer =s recommendations and performance specifications which have been provided by the manufacturer and accepted by the Engineer. The vacuum equipment must be capable of testing the entire manhole, including the casting and riser rings. B. With the vacuum tester set in place: 1. Connect the vacuum pump to the outlet port with the valve open. 2. Draw a vacuum of ten (10) inches of Hg. and close the valve. C. Accepted standards for leakage will be established from the elapsed time for a negative pressure change from ten (10) inches to nine maximum allowable leakage rate for a four (4) foot diameter manhole must be in accordance with the following: Minimum Elapsed Time for a Manhole Depth Pressure Change of 1 Inch Hg D. 16. Water and sewer line crossings and separations shall be in TYPICAL SANITARY SEWER SPECIFICATIONS TO BE USED FOR PRIVATE SEWER DEVELOPMENT WITHIN CLAY TOWNSHIP REGIONAL WASTE DISTRICT REVISED MAY, 2002 10 feet or less 60 seconds >10 feet but <15 feet 75 seconds >15 feet but <25 feet 90 seconds 8 -inch 10 -inch 12 -inch 15 -inch 18 -inch accordance with 3271AC 3 -6 -9. 0.40% 0.28% 0.22% 0.15% 0.12% TABLE 1 MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psig DROP FOR SIZE AND LENGTH OF PIPE INDICATED TABLE 1 inches of mercury. The For manholes five (5) feet in diameter, add an additional fifteen (15) seconds and for manholes six (6) feet in diameter, add an additional thirty (30) seconds to the time requirements for four (4) foot diameter manholes. For all manholes deeper than twenty -five (25) feet. Engineer will determine the applicable minimum elapsed time. If the manhole fails the test, necessary repairs must be made and the vacuum test and repairs must be repeated until the manhole passes the test. E. If manhole joint sealants are pulled out during the vacuum test, the manhole must be disassembled and the joint sealants replaced. F. Manholes will be subject to visual inspection with all visual leaks being repaired. 5. Butyl rubber coating shall be applied around each manhole joint from 6- inches above to 6- inches below each joint. The appropriate primer shall be applied prior to applying the rubber coating. Inside joints to be filled with precoat plug material. 6. The manhole chimney =s including all riser rings shall be sealed using Infi- Shield AUniband© or approved equal. Prior to placement, the top 4- inches of the manhole cone and casting frame shall be cleaned and primed. The Uniband shall extend from 3- inches below the top of the cone section to 2- inches over the flange of the manhole casting frame. 7. The casting elevations are set by plan. However, the castings are to be adjusted in the field by the Engineer =s representative, should a discrepancy occur between pian grade and existing grade. New manhole ring and cover shall be installed to establish grade. Maximum height of adjusting rings shall be 12- inches. 8. Backfill around all structures and all cuts under paved areas with granular material. Trenches opening within 5 -feet of paved roadways shall be backfilled with granular material in accordance with Section 211. Backfill under sidewalks shall be granular, unless the walks are constructed a minimum of 6 months after backfill has been in place. 9, The Contractor shall be responsible for verifying that all state highways, city, and county permits have been obtained by the developer prior to start of construction. 10. The Contractor shall be required to furnish the developer =s Engineer with a set of prints, marked in red pencil, showing actual sewer location and invert, to include lateral location, depth and length. Such Aas built@ prints must be received by the Engineer before the final contract payment can be authorized. The sanitary sewer laterals and stubs termination shall be indicated on the surface with a metal fence post set immediately above the said termination point. 11. All sanitary sewer lines upon completion will be required to pass a low pressure air test. Said test shall be conducted according to ASTM 1417 -92, and shall be witnessed by an Engineer and a representative of the District. The testing shall be in accordance with Table 1. Add 0.5 psig for each foot of water above the sewer line being tested. 12. Deflection tests shall be performed on all flexible* pipe after the final backfill has been in place at le,)st 30 days. No pipe shall exceed a vertical deflection of 5% deflection test results. *The following are considered non flexible pipes: concrete pipe, ductile iron pipe, and cast iron pipe). The deflection test shall be performed with a nine -point mandrel. Proving rings shall be available. 13. All mandrel testing shall be observed by a professional engineer representative for certification and a representative of the District. 14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of withstanding a !ow pressure air test without leakage. 15. Bedding for flexible pipe shall be No. 8 crushed stone from 6- inches below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches below the pipe to the spring line of the pipe and from this point to 12- inches above shat' be fill sand or equivalent. Manholes shall be placed on no less than 6- inches of No. 8 crushed stone bedding. 17. Trench shall be opened sufficiently ahead of pipe laying to reveal obstruction, and shall be properly protected and /or barricaded when left unattended. 18. No water shall be permitted to flow into the sanitary sewer system during construction. Contractor shall utilize a pump to keep the water level below the pipe. Pump discharge shall be directed to a storm outlet in accordance with state and federal laws and regulations (327 -IAC 3- 6 -20). Any pipe entering existing sewers shall be plugged with screw type mechanical, braced plug until such time as all tests on the sewers have been completed and the lines have passed all punch lists. 19. All sewer laterals installed by the mainline Contractor shall be bedded the same as the main line sewer. 20. Forty -eight (48) hours notice shall be given to the District prior to the start of sewer construction. Also, 48 hours notice shall be given prior to doing any testing done on the sewer. 21. Manhole castings shall be stamped SANITARY SEWER, Neenah Casting R 1642A or equal and be self sealing type. The casting flange shall be 34 inches and the clear opening shall be 24 inches. Waterproof castings shall be Neenah R- 1916 -F1 and stamped SANITARY SEWER. 22. The minimum slope for sewer acceptance by the Clay Township Regional Waste District are: Size of Pipe Minimum Constructed Slope progresses. Such measurements shall be certified by than three manhole sections can be constructed in 23. The Contractor shall provide measurements of the slope of the sewer for each manhole section as construction a Registered Land Surveyor or Engineer and be available on -site for observation by the District =s Inspector. No more advance of such measurements. 24. In the event the Contractor does not meet the minimum slopes, the sewer section and any other affected sewer sections shall be reconstructed to meet such minimum slopes. 25. Laterals are to be traced with a minimum size of 14 gauge wire from the wye to the terminus. The contractor for the building or home will extend the wire from this terminus to the building cleanout adjacent to the building. FINISH GRADE INFISHIELD "UNIBAND" BOTTOM OF TRENCH MANHOLE CASTING SCHEDULE MANUFACTURER WATERTIGHT H R- 1916 -F1 1045WT MANUF NEENA EAST JORDAN SELF SEALING R -1642A 1045Z2 CASTING SHALL BE EITHER SELF SEALING OR WATERTIGHT, (SEE PLAN PROFILE SHEETS FOR CASTING TYPE). LIDS SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF KENT SEAL, (SEE MANHOLE CASTING SCHEDULE). PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON SHRINK GROUT PER SPECS 6" MIN. CONCRETE ENCASEMENT 6" MIN. COMPACTED #8 STONE I.D SANITARY MANHOLE TYPE "B" NOT TO SCALE 26" 31" 34" CONCRETE CRADLE NOT-TO-SCALE SANITARY MANHOLE R -1642A NOT-TO-SCALE SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF KENT SEAL MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. 2500 psi CONCRETE PERSPECTIVE VIEW EARTH CUT AWAY TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. TAMPED IN PLACE #8 CRUSHED STONE 1) z J n z 1 III I II: 1 111=_111= 1:I 11 -1 I I -11 I- I li III_ II I I 1 =1 I I 1I FINISH GRADE DX2 (MAX) 0 4. 4 NOTE: ALL BEDDING INTAIL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE 4 4 C.I. MANHOLE FRAME GRATE SET ON KENT SEAL OR EQUAL. 4' -0" DIA. PRECAST REINFORCED MANHOLE SECTIONS MEETING A.S.T.M. STANDARD C -478. PIPE TO MANHOLE GASKET MEETING A.S.T.M. STND. C -443 SHALL BE CAST INTO MANHOLE SECTION AT THE TIME OF MANUFACTORING =III III= II-11 tffl- GRANULAR LEVELING MATERIAL #2 STONE) REQUIRED W /PRECAST BASE 6" MIN. II II I #8 CRUSHED STONE HAND TAMPED OR WALKED IN TO 12" ABOVE PPE. AND 8" BELOW PIPE USE KENT SEAL OR EQUAL BETWEEN RISER RINGS (TYP.) ADJUST TO GRADE w/ FILLER RINGS AS REQUIRED (4" MIN. /12" MAX.) UNDISTURBED EARTH PRECAST REINFORCED CONCRETE MANHOLE CONE MEETING A.S.T.M. STANDARD C -478. BREAK OUT TOP HALF OF PIPE AFTER PLACING CONCRETE BENCH WALL, CONCRETE BENCH WALL (CLASS B) III =III PRECAST REINFORCED CONCRETE MANHOLE FOR SANITARY SEWER NOT-TO-SCALE MANHOLES SHALL BE AIR TESTED IN ACCORDANCE WITH ASTM C1244 -93, STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY THE NEGATIVE AIR PRESSURE (VACUUM) TEST. MANHOLE SECTION JOINTS SHALL CONFIRM TO A.S.T.M. C -443 w/ 0 -RINGS GASKET BETWEEN SECTION, PLUS 1/2" EXTRUDABLE GASKET (KENT SEAL OR EQUAL) TOP OF BENCHWALL SHALL BE AT MIN., ELEV. EQUAL TO TE CROWN OF THE PIPE. BASE SHALL BE POURED IN PLACE OR PRECAST BOTH SHALL HAVE #4 BARS AT 12" 0.0. EACH WAY III III III III III III III 111 I II BEDDING DETAIL NOT- TO- SCALE A MAGNETIC TAPE LOCATOR SHALL BE PLACED 6" OVER ALL MAINS LATERALS #8 CRUSHED STONE BELL HOE EXCAVATED. SANITARY SEWER SERVICE CONNECTION NOT-TO-SCALE NOTE: RISER PIPE WHERE REQUIRED SHALL BE LAID AT 45' SLOPE NOT TO SCALE BACKFILL WITH CLEAN GRANULAR MATERIAL PER REQUIREMENT OF INDIANA DEPARTMENT OF HIGHWAYS (MECHANICAL COMPACTED TO 95% PROCTOR DENSITY). S No. 19358 -o STATE OF 4 Q• ssX EN I gniInInfl' t t APPROVED SURFACE MARKER MAIN SEWER m m W 0 W Ct L.� Z O U W (in CL W D SHEET NO. JOB No.41760S4 m w I- 0 z 0 z w L C800