Loading...
HomeMy WebLinkAboutC3.2 Elevations(2) 2k4 TOP PLATE (2):.2x4.'MIN. (2) 2x4 'MIN. TOP PLATE THIRD FLOOR:: EL. 118'-11 3/4 SECOND FLOOR EL. 109' -5 7/8 FIRST FLOOR EL. 100' -O (2) 4 "0 THRU BOLTS EACH SIDE OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) (2) THRU BOLTS EACH SIDE, OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) (2) 2x. STUDS MIN. SIMPSON HD2A HOLDOWN w/ i"0 THREADED ROD EPDXY GROUTED INTO FOUNDATION WALL w/ EPCON "CERAMIC -6" (2)1"� THRU BOLTS INTO STUDS, TYP. EA. END OF EA. SHEAR WALL (2) 4 "95 THRU BOLTS EACH SIDE OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) PLYWOOD FLOOR SHEATHING SIMPSON CS16 -R STRAP w/ (11) liacl NAILS TOP BOT., TYP. EA. END OF EA. SHEAR WALL (2) 2x4 TOP PLATE WOOD TRUSSES Q 12 "o:c. SIMPSON CS16 -R STRAP w/ (11) 10d NAILS TOP BOT., TYP. EA. END OF EA. SHEAR WALL WOOD TRUSSES 12 "o.c. 4 "6 '6 "4" ff ff II 1' 4' 2' 1 EAST ELEVATION Jii:f _t�.:8..,.. ,aJ�!.: ,ir r•!:v: 'Fd.. .Ea.. i:. 10' TYPICAL SHEAR WALL PANEL (SHOWN SHADED ON PLAN) 16' 2x4 STUDS 16' "o.c. 7/16 "APA RATED SHEATHING NAILED w/ 8d NAILS 6 "o.c. ALONG PANEL EDGES 8c 12 "o.c. AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZ. BLOCKING. 2x4 BOTTI► PLATE d FLOOR 2x4 .STUDS, SPACING INDICATED ON PLAN 7/16"APA RATED SHEATHING NAILED w/ 8d NAILS 6 "o.c. ALONG PANEL EDGES 12 "o.c. AT INTERMEDIATE. SUPPORTS. ALL PANEL EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZ. BLOCKING. PLYWOOD FLOOR SHEATHING 2x4 BOTTOM PLATE 2nd FLOOR 4 2x STUDS, SIZE AND SPACING AS INDICATED ON PLANS 7/16 "APA RATED SHEATHING NAILED w/ 8d NAILS b'o.. ALONG PANEL EDGES 12 "o.c. AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZ. BLOCKING. 1/2"0 ANCHOR BOLTS 24 "o.c., CAST IN PLACE (ONLY AT SHEAR WALL PANELS) P.T.2x BOTTOM SILL PLATE FOUNDATION WALL 32' SIMPSON HD6A HOLDOWN w/ a "O THREADED ROD EPDXY GROUTED INTO FOUNDATION WALL w/ EPCON "CERAMIC -6" (2) 8 "0 THRU BOLTS INTO STUDS, TYPICAL EACH END OF EACH INTERIOR SHEAR WALL (2) 4 "95 THRU BOLTS EACH SIDE OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) (2) 4 THRU BOLTS EACH SIDE OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) (2) 2x4 TOP PLATE (2) 2x4 MIN. SIMPSON CS16 -R STRAP w/ (11) 10d NAILS TOP BOT., TYPICAL EACH END OF EACH INTERIOR SHEAR WALL WOOD TRUSSES 12 "o. (2) 2x4 TOP PLATE (2) 2x4 MIN. (2) SIMPSON CS16 -R STRAPS, ONE EACH SIDE, w/ (11) 10d NAILS TOP BOTTOM, TYPICAL 4 EACH END OF EACH INTERIOR SHEAR WALL WOOD TRUSSES 12 "o.c. (2) 2x4 TOP PLATE 2 11 1 TYPICAL SHEAR WALL PANEL (SHOWN SHADED ON PLAN) 10' 0 2' 2x4 STUDS 16o. 7/16 "APA RATED SHEATHING, ONE SIDE,; NAILED w/ 8d NAILS 6 "o.c. ALONG PANEL EDGES 12 "o,c. AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZ. BLOCKING. (2) "o THRU BOLTS EACH SIDE OF SPLICE. (TYP. THRU -OUT BUILDING UNLESS NOTED OTHERWISE) r FLOO s 2x4 STUDS 16 "o.c. 7/16 "APA RATED SHEATHING, BOTH SIDES, NAILED w/ 8d NAILS 6 "o.c. ALONG PANEL EDGES 12 "o.c. AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZ. BLOCKING. PLYWOOD FLOOR SHEATHING 2x4 BOTTOM PLATE 1' 4' P.T.2x4 BOTTOM SILL PLATE SLAB ON FOOTING 8 ELEVATION I1i:4Vt�• 16'• 2nd FLOOR 2x4 STUDS 16 "o.c. 7/16 "APA RATED SHEATHING, BOTH SIDES, NAILED w/ 8d NAILS 6 "o.c. ALONG PANEL EDGES' 12 "o.c. AT INTERMEDIATE SUPPORTS. ALL PANEL; EDGES MUST BE BLOCKED BY VERT. STUDS OR HORIZi BLOCKING. 1/2"0 ANCHOR BOLTS 24 "o.c., CAST IN PLACE (ONLY AT SHEAR WALL PANELS) X41 TYPICAL 3-STORY INTE1iOR SHEAF WALL 3 CLEAR GLASS, SEE ELVATIONS FOR SPANDREL CLEAR G LASS LOCATIONS SPANDREL GLASS, SEE ELVATIONS FOR SPANDREL CLEAR GL ASS LOCA T 1.. CURTAIN WALL SYSTEM, SEE SHEET A3.1 SPANDREL GLASS, SEE ELVATIONS FOR SPANDREL CLEAR GLASS LOCATIONS 5 A5.2 THIRD FLOOR EL. 11&'-11 3/4" SECOND FLOOR EL. 109' -5 7/8 FIRST FLOOR EL. 100' -O GENERAL NOTES, THIS SHEET: 1. Minimum 4" clearance from brick to grade, typical throughout. 2. Elevation 100' shown for reference only. 3. Brick courses indicated are nominal, see wall sections for actual dimensions. 0 CONSTRUCTION NOTES, THIS SHEET: 1. Brick veneer, Color 1. 2. Curtain wall system: YKK model #YCW 752, 4 7/8" deep system. 3. Brick veneer, Color 2. 4. Storefront system: YKK model #YWE 40T. 5. Clear glass, typ, at Owner's option provied tinted glass to match spandrel. 6. Exhaust grille per GE Zoneline specifications. 7. Concrete foundation wall footing. 8. Not Used. 9. Spandrel glass, typ. 10. Metal coping. 11. Stacked Hock retaining wall. 12. Grade, see site plan. 13. Not Used. 14. Typical brick expansion joint. 15. Typical brick expansion joint, locate at interior corner. t 17 'ViBA Y I.Lr44 Ilii:i wl. 4 ,wi, lCUG4iG Cr1.1:k�t�CIRL'li i!�kL'4....L,: '.GG1�'�`.'.k lip ..l: FRAMING PETA 1" 4" 0 2 8" 2' 1/2" PLASTIC LAMINATE SILL TYP. EXTERIOR WALL, SEE 1/A4.1 2x4 PLATE BTWN.:STIFFENER PL: s w/ MIN. (2) 3/16" 0 RAMSET PINS 4" PLYWOOD SUBFLOOR TS 10x4x3/8" GYP. BD. CEILING OVER R.C. CHANNELS RAMSET PIN 2x4 STUD WALL WI BATT INSULATION 1 Revised Issued: 9 -6 -02 Issued for Permit 1 Addendum architecture planning .interior design s Per associate, 23,59 mper Lane Cincinnati, OTT 4520( TEL: 513.75.1..122J. 'FAX: 51 3.751 .O !2 SCHAEFER ti ASSOCIATES, INC. ONSULTING ENGINEERS 10411 MEDALLION DRIVE, SUITE 121 CINCINNATI, OHIO 45241 (513) 542 -3300 FAX: (513) 542 -5540 Pate: MAR. 2002 Job No.: Corvette and Associates Design Consultant' 2142 Alpine Place Cincinnati, Ohio 45206 Phone (513) 221 -6600 Fax (513) 221 -6606 0 2002 CMC Properties Sheet Number This document and the ideas and designs incorporated herein are the property of Speer Associates. They are not to be used or reproduced in whole or in part Dr any other project or purpos without the written authorization of CMC Properties. A5.2