HomeMy WebLinkAbout03110010 Cherry Creek Estates, Sec. 3 Large Plan pg. 03STORM CHART
STR. NO.
TYPE
T.C. RIM
INVERT
DIRECTION
59
DBL. CURB INLET
764.60
760.00
W
60A
MANHOLE
764.60
759.86
N,S,E
60B
YARD INLET
766.00
762.11
N,S
61
MANHOLE
768.80
763.98
S,E
62
CURB INLET
768.10
764.50
W,E
63
CURB INLET
768.10
764.62
W,NE
64
CURB INLET
768.81
764.77
SW,N
65
CURB INLET
768.81
765.01
S
66
CURB INLET
766.49
762.80
E
67
CURB INLET
764.75
760.51
W,E
68
CURB INLET
764.75
760.63
W
EARTHWORK:
1. EXCAVATION
FORM \EARTHWRK
1848.01
IM.E.I
870
<000
100
874.1
N.P.
MFG
MFPG
a
r
ROLL CURB
LEGEND
EXISTING EDGE OF WOODS
EXISTING CONTOUR
EXISTING SANITARY SEWER
EXISTING STORM SEWER
PROPOSED GRADE
MATCH EXISTING
PROPOSED CONTOUR
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
PROPOSED 5' SIDEWALK (BY HOME BUILDER)
(DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS)
LOT NUMBER
PAD ELEVATION
PAD SIZE: 40'D
(UNLESS OTHERWISE NOTED)
NO PAD
MINIMUM FINISH GRADE
MINIMUM FLOOD PROTECTION GRADE
PROPOSED 6" UNDERDRAINS
EMERGENCY FLOOD ROUTING
(100 YEAR FLOOD EVENT)
APPROXIMATE BORING LOCATION NUMBER
DENOTES 4" SUBSURFACE DRAIN TO LOT
DENOTES 6" SUBSURFACE DRAIN
6" S.b.D.
O RISER
PROPOSED 4" S.S.D.
AAAA 766.52 TYPICAL 100 YEAR ELEVATION
D.U. &S.S.E.
D.U. &S.E.
D. &U.E.
L.M.A.E.
S.L.E.
D.E.
B.S.L.
N.R.
N. A.E.
P.A.E.
T.P.E.
R/W
C.A.
(FFF)
ALL PADS SHOULD BE TESTED TO ASSURE
A COMPACTION OF AT LEAST 95 PERCENT
OF THE MAXIMUM DRY DENSITY USING THE
STANDARD PROCTOR TEST METHOD.
DRAINAGE, UTILITY SANITARY SEWER EASEMENT
DRAINAGE UTILITY SEWER EASEMENT
DRAINAGE UTILITY EASEMENT
LANDSCAPE, MAINTENANCE ACCESS EASEMENT
SIGN LANDSCAPE EASEMENT
DRAINAGE EASEMENT
BUILDING SETBACK LINE
NON RADIAL
NON ACCESS EASEMENT
PUBLIC ACCESS EASEMENT
TREE PRESERVATION EASEMENT
RIGHT OF WAY
COMMON AREA
FLOODWAY PER HEC -RAS CALCULATIONS BY
(FINS) STOEPPELWERTH ASSOCIATES, INC. DATED
FEBRUARY 3, 2003.
FLOODWAY ZONE AE AS SCALED FROM
THE FLOOD INSURANCE RATE MAP (FIRM) FOR
(Fwr) HAMILTON COUNTY, INDIANA, COMMUNITY NAME, CARMEL,
COMMUNITY NUMBER, 180081, PANEL NUMBER, 0227F,
MAP NUMBER 18057CO227F, DATED FEBRUARY 19, 2003.
FLOODWAY FRINGE ZONE AE AS SCALED FROM
THE FLOOD INSURANCE RATE MAP (FIRM) FOR
HAMILTON COUNTY, INDIANA, COMMUNITY NAME, CARMEL,
COMMUNITY NUMBER, 180081, PANEL NUMBER, 0227F,
MAP NUMBER 18057CO227F, DATED FEBRUARY 19, 2003,
LOMR -F CASE #04- 05- 0574A, DATED: JANUARY 28,
2004.
A. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus
excavated material not required shall be removed from the site.
B. Provide and place any additional fill material from offsite as may be necessary to produce the grades
required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the
source approved by the Developer. It will be the responsibility of the Contractor for any costs for
fill needed.
2. REMOVAL OF TREES
A. All trees and stumps shall be removed from areas to be occupied by a road surface or
structure area. Trees and stumps shall not be buried on site.
3. PROTECTION OF TREES
A. The Contractor shall, at the direction of the Developer, endeavor to save and protect trees of value
and worth which do not impair construction of improvements as designed.
B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with
respect to protective measure to be taken, if any, to preserve such trees.
4. REMOVAL OF TOPSOIL
A. All topsoil shall be removed from all areas beneath future pavements or building. Topsoil removal shall
be to a minimum depth of 6 inches or to the depth indicated in the geotechmical report provided by the
Developer to be excavated or filled. Topsoil should be stored at a location where it will not interfere
with construction operations. The topsoil shall be free of debris and stones.
5. UTILITIES
A. Rules and regulation governing the respective utility shall be observed in executing all work under
this section.
B. It shall be the responsibility of the Contractor to determine the location of existing underground
utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free
1- 800 382 -5544 within Indiana or 1- 800 428 -5200 outside Indiana.
6. SITE GRADING
A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area
to subgrade as shown on the drawing.
B. The tolerance for paved areas shall not exceed 0.10 feet above established subgrade. All other areas
shall not exceed 0.10 feet plus or minus the established grade. Provide roundings at top and bottom
of banks and other breaks in grade.
C. The Engineer shall be notified when the Contractor has reached the tolerance as stated above, so
that field measurements and spot elevations can be verified by the Engineer. The Contractor shall
not remove his equipment from the site until the Engineer has verified that the job meets the above
tolerance.
767.2
RE ED
p 11.8c:::E,:
0
131 L.F. 15" R.C.P. 0.60%
120.00'
10' D.U. &S.E.
127
766.0
129
765.8
765.2
15,943 $q. •ff::
(765.71
0 +48.42
d o 0)
U) N
0 (0
50' R7W
146
768.6
(768.6
145.92'
10' D.U. &S.E:
131 L.F. 12" R.C.P.... 1.81%
1765., 70
20.00'
120.00
120.00'
120.00'
0.00'
20.00'
10' D.U. &S.E.
130 L.F. 15" R.C.P. 0.40%
1768.91
120.00'
120.0
120.00'
120.00'
07A 782 €VATI•
�rl_w
,r� 10' ASPHALT PATH BY DEVELOPER
0.40%
768.7
765.1
7 MFPG
764.7
120.00'
120.00'
0.00'
240 L .F.
120.00'
120.00'
MFPG
764.6
MFPG
764.5
MFPG
764.4
3,614 sq. ft.
C.A. #11
109,064 sq. ft.
75' REGULATED DRAIN
EASEMENT
ERR CREEK BOULEVARD
N.
1
45.92
126
767.1
EX.
(767.1
1766.71
-J
0
POWDER DRIVE
N.P. =757.00
2 YEAR ELEV.= 761::50
10 YEAR ELEV.= 761.52
YCAfrLE�T' =76167
1
1
EXI
S
T
N
G MONITORING
(DQ.. N T> Pi STURB
"HOLEY MOLEY"
SAYS:
1 800 382 -5544
CALL TOLL FREE
1 800 428 -5200
FOR CALLS OUTSIDE OF INDIANA
STORM SEWER NOTE
THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER
DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF
CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS.
DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE
PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY
DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD
APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE
CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL
BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH
DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON
AS- BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF
PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES
IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS
(AT FULL FLOW CAPACITY) SHALL REQUIRE AS -BUILT
CERTIFICATION AT THE TIME OF CONSTRUCTION. THE
CONTRACTOR IS INSTRUCTED TO AS -BUILT EACH SECTION OF
STORM PIPE AS IT IS BEING INSTALLED TO ENSURE
COMPUANCE WITH THE DESIGN PLANS. AND AS APPROVED BY
THE CITY OF CARMEL.
SCALE: 1"= 50'
S &A TBM #1:
PWP #056462 ON WEST SIDE CHERRY TREE 1400 CHERRY
TREE RD APPROX. 1'± ABOVE EXISTING GROUND EAST SIDE OF
POLE MINI RAILROAD SPIKE
ELEV.= 778.56
S &A #2:
NORTH BONNET NUT ON FIRE HYRDRANT LOCATED ON WEST
SIDE STUB OF KICKAPOO LN. JUST NORTH OF KICKAPOO LN.
AND ARAPCHO CT. INTERSECTION IN DELAWARE TRACE
SUBDIVISION
CAUTION
ELEV.= 762.05
S &A #3:
MANHOLE TC INT- TION OF STONE PINE TRAIL AND
THORNWOOD DR. :,TONE PINE TR. IN STONE
HAVERSTICK SUBDIVISION
ELEV.= 764.14
ELEV.= 775.59
S &A #4:
TOP STEP ON STOOP SW COR. OF ENTRY TO WELL #17 SW
COR. OF STOOP ON PROPERTY EXCEPTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves,
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILIITIES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
L_
Z
J
W
N N
0
t)
O
0
0,
O
0
0
Lr 1
6 II
0
I.
I-
0
N)
0
Q O
N)
0
rte)
0
0
0
Q
0
z
w
z
LJ
U
SHEET NO.
C200
JOB NO•4340553