Loading...
HomeMy WebLinkAbout03100015 Congressional Flex Space Carmel Science & Tech Park, Construction DetailsDIA. T (Min.) Ax C x D x Ex K 111 R2 Approx. Weight 12" 2" 5" 4' -3" 6' -2" 2'-0" 1.3 101/8" 9" 800 15" 2 7" 4' -0" 6' -3" 2'-6" 1.5 1212" 11" 1100 18" 2 11" 4' -1" 6' -2' 3' -0" 1.8 1512" 12" 1300 21" 2 11" 3'-6" 6' -3" 3'-6" 2.1 16 1/8" 13" 1500 24" 3" 1 -0" 2'-8" 6' -0" 4' -0" 2.3 16 3/16" 14" 1800 27" 3 1' -1" 2' -5" 6' -0" 4'-6" 2.6 16 316" 14 12" 2100 30" 3 1' 2" 1' -10" 6' -3' 5' -0" 2.9 18 12" 15" 2400 33" 3 1' -3" 3'-6" 8' -3" 5'-6" 3.1 23 3/4" 17 12" 4100 36" 4" 1' -5" 3' -1" 8'-3" 6'-0" 3.4 24 516" 20" 4200 D C C B C B C B A B A BIT PAVEMENT 0 N COMP AGGR BASE 10 -0" REACTION PAD 6 CONC. "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY #8 CRUSHED STONE (V4" TO 3/4 #5 BASE ASPHALT #11B SURFACE #9 BINDER #53 STONE EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE Bc OUTSIDE DIAME I ER D INSIDE DIAMETER NOTE: ALL BEDDING BACKFILL TO 12" ABOVE PIPE SHALL BE IN 6" LIFTS. DUMPSTER PAD 4" CONC. SECTION A -A #11 OR #12 SURFACE #53 COMPACTED AGGREGATE in #2 COMPACTED AGGREGATE COMPACTED WELL DRAINED SUBGRADE HEAVY DUTY PAVEMENT SECTION 6" COMPACTED WELL DRAINED SUBGRADE TYPICAL PAVEMENT SECTION SIMILAR STRUCTURE IN THE PUBLIC RAN t.0 5' OR LESS J MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH WITHIN 5' OF EDGE OF PAVEMENT MIN. 12" D/8 OR 6" MIN. 12' -0" t P L D t D P D D DUMPSTER PAD 4" CONC. REGULAR BACKFILL #8 CRUSHED STONE lag (V4" TO 34") 4 4" #53 STONE COMPACTED TRASH DUMPSTER DETAIL SEE ARCHITECTURAL PLANS FOR DUMPSTER PLAN AND ELEVATIONS GREATER THAN 5' SANITARY SEWER BEDDING DETAIL EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE Bc OUTSIDE DIAMETER D INSIDE DIAMETER NOTE: ALL BEDDING BACKFILL TO 12" ABOVE PIPE SHALL BE IN 6" LIFTS. MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH 0 MIN. 12" GREATER THAN 5' FROM EDGE OF PAVEMENT in Grooved end on outlet end Tongue end on inlet end. #8 BINDER 1 OR 6" MIN. #53 STONE 1- 1- #11B SURFACE C I 6 COMPACTED WEL DRAINED SUBG RADE PAVEMENT SECTION FOR 10' ASPHALT PATH r 3" G rooved (or t ongue to b e the same as on Standard Reinforced Concrete Pipe ASTM Designation C -76 #11 OR #12 SURFACE #5 BASE ASPHALT #53 STONE D COMPACTED WELL DRAINED SUBGRADE B (D C) RIGHT OF WAY PAVEMENT SECTION PLAN VIEW A LONGITUDINAL SECTION 9" "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY 1- w LEGEND 0 N CLASS 'A' CONCRETE PRECAST CONCRETE END SECTION EDGE OF PAVEMENT, CURB, GUTTER, OR SIMILAR STRUCTURE IN THE PUBLIC R W /-PAVEMENT ON BASE o 7 SECTION A —A SIDEWALK RAMP DETAIL Bc OUTSIDE DIAMETER D INSIDE DIAMETER d DEPTH OF BEDDING MATERIAL BELOW PIPE NOTE: ALL BEDDING INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS MIN. 9" CLEARANCE EACH SIDE OF INSTALLED PIPE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT DEPTH FOR BEDDING MATERIAL BELOW PIPE D 27" SMALLER 30" TO 60" 66" LARGER x Tolerance 1" CONCRETE IN THESE END SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED CONCRETE PIPE, A.S.T.M. DESIGNATION C-76 CLASS II (AS SET OUT IN STANDARD SPECIFICATIONS) REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR REINFORCED CONCRE I E, A.S.T.M. DESIGNATION C-76 CLASS II FOR THE SIZE OF CONNECTING PIPE. REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER OF STEEL IN THE "C" PORTION. THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES ARE FLUSH. THE JOINT SHALL BE COMPLETELY FILLED WITH MORTOR. IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION APPROXIMATELY 10'-0" IN LENGTH. VARIATIONS IN DIMENSIONS THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL DIAMETER OF THE PIPE SHALL CONFORM WITH THE /ARIATIONS IN DIMENSIONS AS PROVIDED IN THE SPECIFICATIONS FOR REINFORCED CONCRETE CUL'F_RT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION C-76. WHERE VITRIFIED CLAY CULVERT OR CAST IRON CULVERT IS USED, A "PIPE END SECTION" COMPARABLE TO THAT AS SHOWN FOR METAL OR CONCRETE SHALL BE :URNISHED AND SHALL BE AS APPROVED BY THE ENGINEER. EXCEPT IN AREAS OF ACID OR MINE WATEt THEN THE USE OF METAL END SECTION IS PROHIBITED. END SECTIONS WILL BE PAID FOR AT THE CONTRACT UNIT PRICE EACH FOR "PIPE END SECTION" COMPLETE IN PLACE AND ACCEPTED. CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PPE END SECTIONS. THE COST THEROF SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE PER EACH FOR "PIPE END SECTION." (d) MIN. 4 6" POSS. INLET PIPE 6" r POSS. INLET PIPE 8 REINFORCED CONCRETE PIPE (RCP) TRENCH DETAIL WITHIN 5' OF EDGE OF PAVEMENT x=24 FRAME AND GRATE AS NOTED ON STRUCTURE DATA TABLE w z NOTE: 6" CONC. PRECAST OR POURED IN PLACE INLET TYPE "A" (MODIFIED) (12" TO 18 NO SCALE COMPACTED GRANULAR FILL 4" CONCRETE SLAB ON 4' #53 STONE COMPACTED 6 „\OIP LET ft w CLASS "A” CONCRETE SERVICE FROM BUILDING 18" R 6 30" 8" 24"—e- 7-- FRAME AND GRATE AS NOTED ON STRUCTURE DATA TABLE NOTE: 5" CONC. PRECAST OR 'OURED IN PLACE INLET TYPE "J" F4NDICAP SYMBOL NO SCALE 5' R 6 "x6" PVC WYE BRANCH CLEANOUT DETAIL OUTLET PIPE 1 CLASS "A" CONCRETE CLEANOUT ADAPTOR WITH THREADED CAP 20 HEAVY DUTY TOPSOIL BACKFILL SUBSURFACE DRAINAGE TILE REQUIRED IF CHANNEL SLOPE IS BETWEEN 0.5/ AND 1.0/, AND OR LENGTH IS GREATER THAN 400 FEET. RISER PIPE TO BE SAME SIZE AND SPECIFICATION AS HORIZONTAL PIPE R- 4996 -A1 TYPE "M" TRENCH DRAIN TYPICAL SWALE DETAIL 3' FROM BUILDING (TYPICAL) PORTLAND CEMENT 3500 PSI CONCRETE 1 /4" PER Ft. s. MIN. 3' WIDTH PER PLAN 6" GRANULAR BACKFILL A MIN. 6" DIA. PIPE CLEANOUT SHALL BE INSTALLED WITHIN THREE (3) FEET OF OUTSIDE BUILDING WALL. A PLUG SPECIFIED BY THE PIPE MANUFACTURER SHALL BE USED TO ENSURE 100% WATERTIGHTNESS. 1/8 BEND SECTIONS APPROX. 4' 0" LONG REPLACE TOP 6" WITH TOPSOIL VARIES (SEE PLANS) PLAN VIEW 1 /2" SCORE "d Flow depth "s swale slope 1/8" R 2 INTEGRAL WALK AND CURB DETAIL SERVICE WYE N TRUNK LINE LATERAL MINIMUM SIZE 6" 1/8 BEND 6 OUTLET PIPE FILLED SAND BAGS STACKED AND TIGHTLY FITTED AROUND PERIMETER OF INLET TO PREVENT SEDIMENT WASH INTO INLET SANDBAG DROP INLET PROTECTION R 1" COMPACTION OF GRANULAR BACKFILL IS CRITICAL UNDER WYE AND BEND. IF PROPER COMPACTION CANNOT BE ACHIEVED, PLACE A MIN. OF 6" OF CLASS B CONCRETE AROUND 1/8 BEND. MIN. FALL 0.61%. BELL HOLES SHALL BE PROVIDED UNDER PIPE ELEVATION 1" C. I. LOCATOR ROD OR MAGNETIC TAPE INSTALLED PER SECTION 7.02-0 30 SERVICE CONNECTION FOR SHALLOW SEWERS (LESS THAN 15' DEEP) BUILDING LATERAL MINIMUM SIZE 6" x X t Fe 3' A X 1 STAPLE PER 50. YD. x x X1 ,t X X X X X C X x X X a a 0 0 l a 0 0 0 PLAN f 3, -0„ �x 1 1 /2' 1 1 /2 X B X 1* STAPLES PER SQ. YD. X X X X N x x x s '20 X X X X x X X X X X D X X X X X X 2 STAPLES PER 3* STAPLES PER SQ. YD. SQ. YD. 10' MIN. STAKED STRAW BALES (TWO STAKES PER BALE) TAAADCII CENTER OF SEWER MAIN LAYING LENGTH SANITARY SEWER MAIN SANITARY DROP INLET WITH GRATE STRAW BALE INLET PROTECTION NO SCALE MED/HIGH FLOW CH ANN EL SHORELINE LOW FLOW CHANNEL z 2:1 a_ O J 1:1 3:1 4:1 STAPLE PATTERN 18" MIN. 18" MIN. b 0 to O N N N N 6 WATER MAIN SEWER ELEVATION tI) O r- r LI) N T SLOPE LENGTH TOP SOIL O 10 0 f� L) N U EXISTING GROUND COMPACTED, WELL- DRAINED BACKFILL COMPACTED SUBGRADE THE UPPER 6 INCHES SHALL COMPLY WITH THE DENSITY REQUIREMENTS OF THE CONTRACT IMMEDIATELY PRIOR TO PLACING THE MATERIAL THEREON. ALL SOFT,YIELDING OR UNSUITABLE MATERIAL, WHICH CANNOT BE COMPACTED SATIFACTORILY, SHALL BE REMOVED. ALL ROCK ENCOUNTERED SHALL BE REMOVED OR BROKEN OFF AT LEAST 6 INCHES BELOW THE SUBGRADE SURFACE. ANY HOLES OR DEPRESSIONS RESULTING FROM THE REMOVAL OF UNSUITABLE MATERIAL, SHALL BE FILLED WITH SATISFACTORY MATERIAL AND COMPACTED TO CONFORM WITH THE SURROUNDING SUBGRADE SURFACE. WHERE SIDEWALK IS CONSTRUCTED ADJACENT TO THE CURB, THE SPACE BEHIND THE NEW CURB SHALL BE FILLED WITH GRANULAR MATERIAL TO THE REQUIRED ELEVATION AND COMPACTED IN LAYERS NOT TO EXCEED 4" WHERE SIDEWALK IS NOT CONSTRUCTED ADJACENT TO THE CURB THE SPACE BEHIND THE CURB SHALL BE FILLED WITH SUITABLE MATERIAL TO THE REQUIRED ELEVATION AND COMPACTED IN LAYERS NOT TO EXCEED 4 6" VERTICAL CURB MAIN MINIMUM CROSSING SEPARATION REQUIREMENTS FOR WATER SANITARY SEWER MAINS mo �iSTE F O P, cc No. 0 a) U a) U W 0 o 9 :00348 o STATE OF 0 il NA1 V ////1111111111 111111, l,r 4-(44 44 34 0 a) 0 0 0 W 0 0 z N O N a) o co co 45 cD a) cn c ro_ o m O rn z c\ Q z CE tL Q O O =z Q c Q- U o a: O C DATE: 03 SCALE: N/A PROJECT NO. 122 -0146 SHEET NO. 10 OF 10 0146 -det1. DGN