HomeMy WebLinkAbout03100015 Congressional Flex Space Carmel Science & Tech Park, Site Construction Plan pg. 0415' UTILITY EASEMENT
8' 8' 8'
TYP
BUILDING THREE
12,406 S.F.
FFE 844.70
232. 99' 10' SIDE/REAR LANDSCAPE YARD
BUILDING ONE
12,406 S.F.
FFE 844.70
111.05
BUILDING TWO
19,270 S.F.
FFE 844.70
10' SIDE/REAR YARD SETBACK
-4 00
BENCHMARK NOTE
TBM 111- 1094 -01 FND. CUT TOP EAST FACE OF LITHE POLE CONCRETE BASE;
LOCATED 300' SOUTH OF CARMEL DRIVE, ON WEST SIDE OF
ASPHALT DRIVE AND AT SE CORNER OF #1185 CARMEL DRIVE
LOT 3, OUTLOT 17 IN CARMEL SCIENCE TECHNOLOGY PARK.
ELEVATION 847.83
TBM #1
NW CORNER TRANSFORMER PAD LOCATED 40' +1- SOUTH
OF THE CENTERLINE OF 122nd STREET AND 50' +1- WEST OF
THE CENTERLINE OF CONGRESSIONAL BOULEVARD.
ELEVATION 843.80
DISABLED PARKING SYMBOL
PARKING SPACES COUNT
CONCRETE
HEAVY DUTY PAVEMENT
PLAN NOTES
GENERAL NOTES:
SITE DATA
LEGEND
BITUMINOUS PAVEMENT
HEAVY DUTY PAVEMENT
RIGHT -OF -WAY PAVEMENT
6" EXTRUDED STRAIGHT CURB
CONCRETE HANDICAPPED RAMP
INTEGRAL WALK AND CURB
LANDSCAPE AREA
CONCRETE SIDEWALK
CURB AND GUTTER
NOTE:
REFER TO ARCHITECTURAL PLANS FOR
DUMPSTER ENCLOSURE PLAN AND
ELEVATIONS.
NOTE:
REFER TO ARCHITECTURAL PLANS FOR
SIGN PLAN, DETAILS AND ELEVATIONS.
1. ALL RADII DIMENSIONS ARE MEASURED TO BACK OF CURB
UNLESS OTHERWISE NOTED.
2. SEE DETAIL SHEETS FOR PAVEMENT SECTION.
3. FOR GRADING PLAN, SEE SHEET 5.
4. FOR UTILITY PLAN AND UTILITY RELOCATION, SEE SHEET 6.
5. FOR CONSTRUCTION DETAILS, SEE SHEET 11.
6. DO NOT SCALE FROM THESE PLANS FOR SURVEY FIELD
LOCATIONS.
7. ENDS OF ALL CURBS TO BE CHAMFERED.
8. SEE RECORD SURVEYS FOR EXACT INFORMATION REGARDING
BOUNDARY, EASEMENTS, AND RIGHT -OF -WAY.
9. SEE ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS, DOOR
LOCATIONS, SIDEWALK CONSTRUCTION, GATE TYPES AND
SPECIFICATIONS AND FIREWALL LOCATIONS AND MEASUREMENTS.
10. ALL PARKING STRIPES TO BE 4" PAINTED WHITE, UNLESS
OTHERWISE NOTED.
11. DIMENSIONS SHOWN ARE FEET AND DECIMAL PARTS THEREOF.
12. ALL SITE IMPROVEMENTS SHALL MEET CURRENT ADA STANDARDS.
13. REFER TO ARCHITECTURAL PLANS FOR DETAILS AND EXACT
LOCATIONS OF WALK -IN DOORS.
SITE ACREAGE:
ZONING:
SITE COVERAGE (Hard Surface):
PARKING SPACES:
4.022 AC +1
M -3
78%
Regular Parking 112
Accessable Parking 6
Total Provided
Total Required
Office Space (30,000 SF)
Warehouse Space (1 /Employee)
Req'd Min. Number of Accessable Spaces
BUILDING SIZE:
BUILDING ONE BUILDING TWO
12,406 +1- SF 19,270 SF
118
115
100
15
BUILDING THREE
12,406 SF
1-800-382-5544
CALL BEFORE YOU DIG
DATE: 03/05/2004
SCALE: 1" 30'
PROJECT NO. 122-0146
SHEET NO.
0146 -s1. DGN