HomeMy WebLinkAbout03110003 Meridian Technology Center, Corvasc Medical Office Building, Construction Plans pg. 04DATE:
10/30/03
I
REI INVESTMENTS
INDIANAPOLIS, INDIANA
r
DRAWN BY:
RDR
CHECKED BY:
M SO
SHEET TITLE:
SITE GRADING
PLAN
DRAWING FILES:
S: \1211 \018 \DWGS \C102
XREF: S: \1211 \018 \dwgs \018bs.dwg
XREF: S: \1211 \019 \dwgs \12110191.dwg
XREF: S: \1211 \018 \dwgs \Titlel.dwg
XREF:
SHEET NO.•
C11.02
Z)
F1
IA
DATE:
10/30/03
PROJECT NC'
1211.018
r
DRAWN BY:
RDR
CHECKED BY:
M SO
SHEET TITLE:
SITE GRADING
PLAN
DRAWING FILES:
S: \1211 \018 \DWGS \C102
XREF: S: \1211 \018 \dwgs \018bs.dwg
XREF: S: \1211 \019 \dwgs \12110191.dwg
XREF: S: \1211 \018 \dwgs \Titlel.dwg
XREF:
SHEET NO.•
C11.02
t
MATC 1
1 r)*I
I',) THE r
ADJACENT USE
GENERAL BUSINESS
4
m
N
848 .25 TC
1 847.75 GU
84
1
849.9
PROPOSED MEDICAL OFFICE
16,210 SF
FFE 852.00
851.50
51.501
850.35 TC
849.85 GU
FUTURE EXPANSION
14,800 SF j
849.4
85 TC
35 MI
TC
0 GU
1 847.75 TC
847.25 r
1 847.70 TC
E GUT
847.90 TC
847.40 GUT
847:7
046.77 GU
TIC
5 GI,
847.32 IC
8 .8' GUT
48. TC
60 GUT
X48.00 TC
847.50 MI
47.50 TC
847.00 GUT
46 85 TC
846 35 GU
GUT
81-6.45 I 1
DUMP
STER R.
G,.90 GUG
847..0 IC
8 GO
,,847.00 TC
846.50 Gi
15 TC
65 GU
TC
8468
TC
8 GUT
55' ASPHALT PATH
(I 848 80
N88'46' 55 "E
65.81'
rT
48
GUT
849 IC
848 %0 GU l
848.45 GUT
T
10' STORM EASEMENT
COLLEGE DRIVE
0 1
GUT
i\
849.45 T
848.95 DA .1
AD E: b /LA,-;
r
18`i
849 75 13
850.15
L/1/: 5
d4
50.50 1C
.50 00 GUT
8G(i 5(8
J 1(
849.
N86'17'591E 165.13'
ADJACENT USE
GENERAL BUSINESS
5' ASPHALT PATH
ADJACENT USE
GENERAL BUSINESS
1\183'49'
53.51'
404.19'
N 86'17' 59 "E
120.55'
845.51M.8.
ADJACENT USE
GENERAL BUSINESS
DISCLAIMER FOR THE USE OF DIGITAL FILES
THE INFORMATION CONTAINED WITHIN THIS DISK OR
ELECTRONIC MAIL IS AS IT APPEARS ON THE SCHNEIDER
CORPORATION'S ELECTRONIC FILES.
By accepting delivery of this Digital File, the receiver agrees to indemnify
and hold harmless The Schneider Corporation, their clients, officers, agents,
and employees from and against any damages, including but not limited to
reasonable attorney's fees, resulting from the use, distribution, change, or
modification of the information contained within without the express written
permission from The Schneider Corporation.
The receiver further understands that the information that may be included
within is subject to periodic revisions by The Schneider Corporation or the
Client and therefore the information contained within is not warranted in any
way.
c�Il� crc� INKYIIES
ALL GRADES AT BOUNDARY SHALL MEET EXISTING GRADES.
2. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO
VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING
TO THE PHASE OF WORK. IT SHALL ALSO BE THE
CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF
THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION FOR
EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR
SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF
ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE
PLANS OR IN THE HELD BEFORE WORK IS STARTED OR
RESUMED.
3. STANDARD SPECIFICATIONS FOR THE CITY OF CARMEL,
INDIANA SHALL APPLY FOR ALL SANITARY SEWER AND STORM
SEWERS.
TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO
CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS.
5. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE
PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A.
STANDARDS FOR WORKER SAFETY.
6. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES.
REMOVE AND BACKFILL ALL AREAS WHERE ANY FIELD TILE
CROSSES PROPOSED BUILDING PADS. ALL FIELD TILES
INTERCEPTED TO BE PERPETUATED INTO STORM SEWER
SYSTEM OR LAKE. THE SUBCONTRACTOR SHALL NOTIFY IN
WRITING THE OWNER AND THE ENGINEER IN ANY
CIRCUMSTANCES WHERE THIS CANNOT BE ACCOMPLISHED.
8. ALL FILL AREAS SHALL BE COMPACTED TO AT LEAST 100
PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D- 1557).
9. ALL A.D.A. PARKING SPACES AND ACCESS AISLES SHALL BE
LEVEL WITH SURFACE SLOPES NOT EXCEEDING 1:50 (2 IN
ALL DIRECTIONS TO COMPLY WITH A.D.A. REQUIREMENTS.
10. ALL SIDEWALK CROSS SLOPES SHALL NOT EXCEED 1:50 (2
OTE
ALL TOPSOIL SHALL BE REMOVED BEFORE REMAINING EARTHWORK ACTIVITIES COMMENCE. ONLY
TOPSOIL CAPABLE OF BEING USED ON -SITE MAY BE STOCKPILED ON -SITE IN LOCATION DESIGNATED
BY OWNER. ALL EXCESS TOPSOIL SHALL BE HAULED OFF -SITE AT NO ADDITIONAL COST TO OWNER.
ASSUMED NORTH
SCALE: 1 30
G
T
000.00
Air
H
w
HOLEY MOLEY SAYS
"DON'T
DIG
BLIND"
"IT'S THE LAW"
CALL 2 WORKING DAYS BEFORE YOU DIG
1- 800 -382 -5544
CALL TOLL FREE
PER INDIANA STATE LAW IS -69 -1991.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
Existing Storm Sewer
New Storm Sewer
Subsurface Drain (ssD)
Existing Sanitary Sewer
New Sanitary Sewer
(Laterals are shown for reference only)
Existing Contour
Existing Elevation
Proposed Finish Grades
Swale Grade
Swale Flowline
Flow Arrow
Utility Sc Drainage Esmt.
Building Setback Line
Existing Water Main
New Water Main
Existing Fire Hydrant
New Fire Hydrant
Existing Water Valve
New Water Valve
New Gas Main
New Electric Line
New Telephone Line
Existing Utility Pole
Existing Trees
Existing Fence
DATE: 4 2 6
THS DRAW!rJG AND TI -1E IDEAS, [L ::r-j. AND
CONCEPTS S cC"a TAINED ItPEIN ARE I
HIELLEJUAl. PROPERTY NT i OF THE lf' lEF
PPORAT10N AND PE NOT TO BE.
F I 3D CE D, WHOLE. OP f> PT, w THOU 1..
14'L WRITTEN CONSENT OF THE CHNEPD[r'
TORPOR, T OrJ-
4PYr=. HTED BY THE SCHNEIDER
t 41 114
Schneider
THE SCHNEIDER CORPORATION
Historic Fort Harrison
8901 Otis Avenue
Indianapolis, IN 46216 -1037
Telephone: 317.826.7100
Fax: 317.826.7200
www.schneidercorp.com
Architecture
Civil Engineering
Environmental Engineering
Geotechnical Services
GIS LIS
Home Builder Services
Interior Design
Land Surveying
Landscape Architecture
Transportation Engineering