Loading...
HomeMy WebLinkAboutC04.0 Utility PlanSTR. N0. STRUCTURE TYPE NEENAH CASTING NO. 101 INLET A MOD. R -3405 102 INLET "A" MOD. R -3405 103 INLET "A" MOD. R -3405 104 5X5 BOX R -3405 104A 5X5 BOX R- 3286 -8V 105 5X5 BOX R- 3286 -8V 106 INLET "J' R -1772 107 INLET "A" MOD. R -4342 108 INLET "J" MOD. R- 3286 -8V 108A INLET "J" MOD. R- 3286 -8V 109 5X5 BOX R -1772 110 INLET "J" R 3286 8V 111 5X5 BOX R -3405 112 5X5 BOX R -3405 113 INLET "A" MOD. R -3405 114 INLET A MOD. R -3405 115 5X5 BOX R -3405 116 5X5 BOX R -4342 117 DELETED 118 MANHOLE R -1772 119 96" DIA. MANHOLE R -3405 120 96" DIA. MANHOLE R -3405 121 96" DIA. MANHOLE R -3405 122 INLET "A" MOD. R -3405 123 INLET "A" MOD. R -3405 124 96" DIA. MANHOLE R -3405 125 INLET "J" R- 3286 -8V 126 INLET "J" R- 3286 -8V 127 INLET "J" R- 3286 -8V DWN BY: JCB CHKD. BY: BSC SCALE: 1" 30' DATE: 10/19/05 FLAIR BLDG. #7 BLDG. #5 137 LF F 42" RCP 0 LF OF 12" RCP 1.87% 96 H D I A. RIM 832.15 INV. W =824.5 INV. E 824.50 INV. S =828.551 1O \NHOLE MANHOLE (96" DIA.) 20 RIM= 832.00 INV. W 824.50 INN. E 823.50 MANHOLE 96" DIA. RIM= 830.85 INV. W 823.50 INV.N= 821 ,44 ISAWCUT at REMOVE INV.S= 21.44 :EXISTING ST ING ,PAVEMENT RIM INV.W 40 LF 12" 38' OF 15" PVC 00.15% 12' VCP it=e OD. RIM= 831.85 w w (PRIVATE) 5'X5' BOX 29 LF OF 12" RC 5'X5' BOX INV.E -3.50 BLDG. #8 BLDG. #9 BLDG. #10 15' SANITARY SEWER EASEMENT (TYP.) MANHOLE T. .W= 821.95 .E= 821.85 TAR' 68 LF OF 42" RCP NHO' 1 33..1.0F 8 r ..PVC 0 0. BLDG. #18 5'X5' BOX Rim =829.10 INV :E =�22.� RIM= 828.00 INV.N= 823.90 INV.S= 824.00 INV.W= 824.10 -(PR /1�ATE 83 LF OF 8" PVC BLDG. #2 MANHOLE 0 INV.W= 821.89 INV.S =821.99 BLDG. #14 BLDG. #17 RIM.= 828.42 INV.= 825.27 BLDG. #1 MANHOLE T.C.= 836.45 INV. 829.78 BLDG. #6 T37 1T 12 RCP ALDEN WAY (PRIVATE) (PRIVATES 71 LF OF 42"i? 128 IF 12" RCP 0 2.00% 367 LF OF 8" PVC 0 1.50% NEUMAN WAY RIM 834.86 INV. E 831.25 BLDG. #4 CONTRACTO TO FIELD VERIFY LOCATION OF EXISTINhh�p WATERMAIN ND INVESTIG TE POSSIBLE INTERFERENCE I I 27 LF OF 12" RCP 0 2.75 Man Hole (Telephone) RIM 833.00 INV. N 829.65 IhV. w 829.75 _2.08 22.08 2.007 BLDG. #13 124 IF OF 12" RCP 0 0.50% INLET TYPE "J" RIM =828.50 INV.=824.80 BLDG. #15 BLDG. #16 INV.N= 824.39 INV.S= 824.29 15' DRAINAGE EASEMENT (TYP.) CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING WATERMAIN AND INVESTIGATE POSSIBLE INTERFERENCE INLET TYPE MO Lot 22 INLET TYPE "A" MOD FH V (Plat Book 2, page 277) "DON'T DIG BLIND" NORTH, SECTION ONE WV "HOLEY MOLEY" SEZ: "IT'S THE LAW" INDIANA UNDERGROUND PROTECTION SERVICE INC. CALL TWO WORKING DAYS BEFORE YOU DIG 1 -800- 382 -5544 CALL TOLL FREE 1- 800 428 -5200 FOR CALLS OUTSIDE OF INDIANA Lo2i R -4 INV. E 833.50 INLET TYPE "J" R -2 ALL PAVING WITHIN THE EXISTING ANt PROPOSED RIGHT -OF -WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY. Lot 20 INLET TYPE "A" MO[. INV. W 830.50 INV. S 830.30 m RIGHT -OF -WAY NOTE ALL PAVING TO BE REMOVED AND REPLACED WITHIN THE EXISTING AND PROPOSED RIGHT -OF -WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING STANDARD STREET CUT PATCH DETAIL CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY. PAVING NOTE Qd L AN DSCAP LEGEND: 18191 830 w INLET TYPE "A" MOD EX. SANITARY MANHOLE NO.2 TC;= 831.60 CONNECTIONS UNKNOWN SAWCUT REMOVE EXISTING PAVEMENT 41 IF OF 12" RCP INV. F.- aorlc M GM 3Icie 51 WITH NON- SHRINK GROUT. L SANlT/ RY PLUG AND SEAL NORTH INVERT TC =2.a0 IN =821.07 NEW EAST INVERT 821.65 (PROP. 15" PVC) INV.tj. =82i 65 SAWCUT, REMOVE REPLACE EXISTING PAVEMENT PROPOSED CONTOUR PROPOSED STORM STRUCTURE PROPOSED SANITARY STRUCTURE PROPOSED DRAINAGE SWALE EXISTING CONTOUR EXISTING MANHOLE EXISTING INLET FLOW DIRECTION PROPOSED WATER LINE PROPOSED WATER METER AND SERVICE UNE PROPOSED STORM SEWER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT MANHOLE T.C.= 831.20 INV.S= 821.10 PROP. 15" PVC) INV.W= 821.10 EX. 15" VCP) INV.E= 821.10 15" VCP) EX. SANITARY MANHOLE NO.3 TC =830.43', INV.E. =820.93 INV.W. =821.03 IN N. =82 33 E INLE TYPE T II ;To .\y 0 I Storm `rd r 12[ WV r fl 0 0 FH r l i r fl I \J Of/ h ve t 8 LF OF 12" RCP 0 2.58% CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING WATERMAIN AND INVESTIGATE POSSIBLE INTERFERENCES 101 LF OF 15" PVC 0 0.15% f: ,-C -828.37 INV.E. =821.12 MANHO ES. =824.87 T.C. =829.60 (MATCH DC. ROAD GRADE) INV.W 821.59 (PROP. 15" PVC) INV.W =822.11 DC. 12" 15" INV.E 821.59 PROP. 15 PVC) OLD TOW \E VILLIAGE Lot I 91.98' EX MAIN B -3 UTILITY PLAN GENERAL NOTES: 1. ALL POINTS OF CONNECTION OF PROPOSED SANITARY AND STORM SEWERS TO EXISTING SYSTEMS MUST BE VERIFIED FROM A KNOWN BENCHMARK VERTICALLY AND HORIZONTALLY BEFORE START OF CONSTRUCTION. ANY CONFUCT WITH THE PLANS MUST BE REPORTED IMMEDIATELY. 2. ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL AFFECTED UTILITIES AND THE LOCAL UTILITIES PROTECTION SERVICE PRIOR TO ANY CONSTRUCTION. 3. LENGTHS OF PIPES INDICATED ARE FROM CENTER TO CENTER OF STRUCTURES AND ARE NOT ACTUAL PIPE LENGTHS. 4. CONTRACTOR SHALL CALL 1 -800- 382 -5544 FORTY -EIGHT (48) HOURS PRIOR TO CONSTRUCTION FOR ALL EXISTING UTILITY LOCATIONS. 5. SEE SHEET C2.0 FOR SITE PLAN. 6. SEE SHEET C3.0 FOR GRADING PLAN. 7. SEE SHEET D100 FOR CONSTRUCTION DETAILS. 8. 4" PVC CONDUIT REQUIRED FOR ALL ELECTRIC, TELEPHONE, CABLE, ETC. CROSSINGS UNDER PAVEMENT. 9. ROOF DRAIN CONNECTIONS TO BE DETERMINED IN FIELD. 10. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE CONSTRUCTION MEETING TO REVIEW THE DEPARTMENTS CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY AND THE SPECIFICATIONS NOTED IN THE PLANS. (Instrument Number 9709749345) (Plat Cabinet 2, Slide 49) 1 O O 0 N 1 rICret -,,Iae` a k Lot 2 R -4 60.01' Lot 60.01' III i t' 63 WV 1IN?ET =524.01 6 NORTH 30 0 15 30 c1■!!■#1 IN FEET 1 inch 30 ft. 0 O N N i m 5'X5' BOX RIM =B 8. 0 I 5'X5' BOX sang I 53 if OF 15 RCP 0 25% (GROUT 7" ORIFICE v STORM MAr•11 H01 T(: =u; INV. E.-8`i' 2.5: 817.47 REV DATE DESCRIPTION DES BY APP BY C 0 N cD 0 (39 0) 0 L I L 1 EX. MANHO RR LE 1 REVISION RECORD STRUCTURE CASTING TYPE INSTALLATION WITHIN EXISTING AND PROPOSED CITY RIGHT -OF -WAY p EDDING, HAUNCHING, AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTIUTY THAT HAS JURISDICTION OVER THE INSTALLATION. FINAL BACKFILL FOR I WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND S ANITARY SERVICE LATERALS UNDER AND WITHIN 5 FEET OF PAVEMENT (INCLUDING SIDEWALKS) SHALL BE B- BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF IINDOT AND SHALL BE COMPACTED IN 6 INCH MAXIMUM LIFTS TO NOT I LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE ;DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6 NCHES OF THE EXCAVATION BELOW THE START OF THE AGGREGATE R Q P SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE 'MATERIAL REQUIREMENTS OF INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD !PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE ;INSTALLATION HAS A MORE STRINGENT FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. ti BEDDING, HAUNCHING, AND INITIAL BACKFILL FOR ALL RCP I I NSTALLATIONS SHALL BE B- BORROW FOR STRUCTURE BACKFILL I MEETING THE MATERIAL REQUIREMENTS OF INDOT. BEDDING SHALL BE I PLACED IN THE TRENCH BOTTOM SUCH THAT AFTER THE PIPE IS (INSTALLED TO GRADE AND UNE, THERE REMAINS A 4 INCH MINIMUM DEPTH OF MATERIAL BELOW THE PIPE BARREL AND A MINIMUM OF 2 INCHES BELOW THE BELL. BEDDING SHALL BE PLACED TO BE UNIFORM AS POSSIBLE, BUT SHALL BE LOOSELY PLACED UNCOMPACTED MATERIAL UNDER THE MIDDLE THIRD OF THE PIPE PRIOR TO PLACEMENT OF THE PIPE. HAUNCHING AND INITIAL BACKFILL SHALL BE COMPACTED IN 8 INCH MAX. LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL SHALL BE BROUGHT UP EVENLY ON BOTH SIDES OF THE PIPE FOR THE FULL LENGTH OF THE PIPE. HAUNCHING SHALL EXTEND TO THE SPRINGLINE OF THE PIPE. THE LIMIT OF INITIAL BACKFILL SHALL BE 6 INCHES ABOVE THE SPRINGLINE. MINIMUM TRENCH WIDTH SHALL BE THE OUTSIDE DIAMETER OF THE PIPE PLUS 18 INCHES. FINAL BACKFILL FOR ALL RCP INSTALLATIONS UNDER AND WITHIN 5 FEET OF PAVEMENT (INCLUDING SIDEWALKS) SHALL BE B-- BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF INDOT AND SHALL BE COMPACTED IN 6 INCH MIN. LIFTS TO NOT LESS THAN 95 STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6 INCHES OF THE EXCAVATION BELOW THE START OF THE AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO.53 STONE MEETING MATERIAL REQUIREMENTS OF INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. FINAL BACKFILL FOR ALL RCP INSTALLATIONS GREATER THAN 5 FEET FROM ANY PAVEMENT SHALL BE CLEAN FILL MATERIAL FREE OF ROCKS LARGER THAN 6 INCHES IN DIAML.I ER, FROZEN LUMPS OF SOIL, WOOD OR OTHER EXTRANEOUS MATERIAL, COMPACTED IN 12 -INCH MAXIMUM LIFTS TO NOT LESS THAN 90% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE EXCAVATION. t `�,GG LE�s "?',74/44: 2� N9 r STATE OF 0, :Ito S '0NALS" t s• S "III I WO DATE: CEC PROJECT NUMBER 051872 U DRAWING NUMBER C4.0 SHEET 6 OF 16