Loading...
HomeMy WebLinkAboutC10.1 Standard DetailsMANHOLE MAXIMUM PIPE SIZE RT. TO MAINUNE N.../.L V Al LA, i.Jll V 11 V1111ZV i14C.il V V 1117 1.C1 VCC11 Viz 1 11- 4 10 West Market Street, Suite 1360 y L Indianapolis, Indiana 46204 -2960 If/ Elf (317) 655 -7777 (877) 746-0749 Pittsburgh, PA Cincinnati, OH Columbus, OH 24" to 36" 60" 30" 36" 36" to 48" 72" N 48" 48" to 54" 96" 48" DWN BY: JCB CHKD. BY: EAG SCALE: N.T.S. DATE: 10/1 2/05 72" 72" to 84" 108" 72" 84" 3' -6" 3' -0" 5" 21" 3' -11" D 6" NT A] 3RD. 4EL, 4' -3" 3' -8" 6" 27" 5' 6" 3' 11" 6" 30" 5' -9" CEC PROJECT NUMBER 051872 DRAWING NUMBER c1o SHEET 1 4O 16 36" MANHOLE MAXIMUM PIPE SIZE RT. TO MAINUNE MAXIMUM PIPE SIZE FOR MAINUNE 24" to 36" 60" 30" 36" 36" to 48" 72" 36" 48" 48" to 54" 96" 48" 54" 54" to 72" 102" 66" 72" 72" to 84" 108" 72" 84" S ZE 6" 2 -6 "U 2 O 4 8" 2' -6" 2' -1 4" 10" 2' 6" 2' 3" 4" 12" 2' -9" 2' -5" 4" 15" 3' -0" 2' 8" 5" 16" 3' 3" 2' 10" 5" 18" 3' -6" 3' -0" 5" 21" 3' -11" 3' -4" 6" 24" 4' -3" 3' -8" 6" 27" 5' 6" 3' 11" 6" 30" 5' -9" 4' -4" 6" 36" 6' -3" 5' 2" 6" 42" 6' -11 8" 48" 7' -4" 9" 54" 8' -O" 9" 60" 8' -6" 9" 66" 9' -1" 9" 72" 9' -8" 10" 78" 10' -3" 10" ID d (MIN) 27" SMALLER 3" 30" TO 60" 4 66" LARGER 6" DIMENSIONS (INCHES) A (MAX) B (I.D.) C (MIN) 18 48 25 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 TOPSOIL a. CO 1/2" CEMENT MORTAR PRE-CAST CONC. MANHOLE MIN. MIN. GRADE LAWN AREA 1. WATER MAIN SHALL NOT BE LOCATED IN THE SAME TRENCH AS SANITARY SEWERS. \j 2. SEPARATION OF 3 FEET WITH ANY UTILITY MINIMUM ANGLE OF INTERSECTION 45? WATER MAIN LAYING PARALLEL TO SEWER 10' s N WATER MAIN /j SEWER CLASS "A" CONCRETE PAVEMENT AREA 10' MIN. NEENAH R -1772 (SOLID) OR NEENAH R- 3286 -8V (CURB) OR NEENAH R -3405 PAVED AREA) 11 s‘.4 4r •lowerdalminrs. NOTE: DROP PIPE MAY BE USED WITH MANHOLES TYPE H THRU N AND SHALL BE REFERRED TO AS DROP MANHOLE TYPE H THRU N. SPECIAL STORM MANHOLE NOT TO SCALE 3 SANITARY OR STORM SEWER 10' l\i SEWER o- a 0• TRENCHED IN PLACE Ak ANOTHER UTILITY FACILITY (TELEPHONE, GAS, ELECTRIC, CABLEVISION, ETC.) WATER MAIN. SEWER/WATER LINE SEPARATION NOT TO SCALE TYPICAL DEPTH OF WATER MAIN 6" TO 8" PIPE SHOULD HAVE A MINIMUM OF 3' OF COVER WHEN THE WATER MAIN PASSES BELOW A SANITARY SEWER OR STORM SEWER, BOTH THE WATER MAIN AND SEWER SHALL BE CONSTRUCTED OF SUP -ON OR MECHANICAL JOINT CAST OR DUCTILE IRON PIPE, PRESTRESSED CONCRETE PIPE, OR PVC PIPE EQUIVALENT TO WATER MAIN STANDARDS OF CONSTRUCTION. WATER MAIN CROSSING BELOW SEWER COMPACTED GRANULAR BACKFILL -REDUCER CAP 6" COMPACTED #53 STONE #4 REBAR 0 6" O.C. EACH WAY. TRENCH SCHEDULE PLACE 1 /2" DIA EXTRUDABLE PREFORMED GASKET MATERIAL IN EACH KEYWAY (SEE DETAIL) NON- ASPHALTIC MASTIC OR BUTYL RUBBER PLASTER ACCEPTED ALTERNATIVE. GASKET DETAIL SPECIAL BACKFILL UNDER PAVEMENT, DRIVES, WALKS OR WHERE ORDERED TAMPED IN 6" LAYERS SPECIAL BACKFILL SHALL CONFORM TO INDOT 211.02B TABLE IS FOR ASTM D -3034, WALL THICKNESS CLASS SDR 35 FOR 6 -15" AND ASTM F -679 WALL THICKNESS CLASS T -1 FOR 18 -36 FOR OTHER FLEXIBLE PIPES, MINIMUM TRENCH WIDTH "U" SHALL MEET MANUFACTURER'S REQUIREMENTS. NEENAH R -1772 (SOLID) 0 NEENAH R- 3286 -8V (CURB) OR NEENAH R -3405 (PAVED AREA) 1/2" CEMENT MORTAR 6" MIN. PRECAST MANHOLE SECTION MAX. OPENING 4" GREATER THAN O.D. OF PIPE PAVEMENT AREA LAWN AREA OMINAL 1/2" BUTYL RUBBER BASE EXTRUDABLE PREFORMED GASKET MATERIAL (TYPICAL) PRECAST CONCRETE ADJUSTING RING OR FLANGE OF CASTING NOT TO SCALE 1' -0" MINIMUM UNDISTURBED GROUND EXISTING PAVEMENT, SAW CUT STRAIGHT EDGE WARNING TAPE 18" ABOVE NEW PIPE UNDISTURBED EARTH ,lam �i0.111 rw.a� 41. r rlt �ru 6" TOPSOIL TRENCH DETAIL FOR SEWER AND WATER MAINS NOTES: 1 UNDER EXISTING SEWERS, WATER UNES, GAS ONES, TELEPHONE CABLES ELECTRICAL CONDUITS, BACKFILL WITH GRANULAR BEDDING MATERIAL TO THE CENTERLINE OF THE EXISTING UTIUTY UNES 2. "W" IS THE MAXIMUM WIDTH FOR RIGID PIPES "U" IS THE MINIMUM WIDTH FOR FLEXIBLE PIPES IN ACCORDANCE WITH ASTM D -2321 ONCRETE "0" RINGS 8" PRECAST REDUCER CAP 24" I.D. 1" I 34" OR 36" O.D. SECTION A -A ADJUSTING RING DETAIL z 6" #4 REBAR 6" O.C. EACH WAY MANHOLE STEPS REQUIRED IF DEPTH EXCEEDS 4' -0" (AT 16" MAX. ON CENTERS) PLAN "W" OR "U" AT TOP OF PIPE TRENCH DETAIL TRENCH SCHEDULE NOT TO SCALE NON- SHRINK GROUT BARREL SECTION ASTM C -478 CLASS A REINFORCED CONCRETE PIPE 4000 PSI 4" COMPACTED #53 STONE MATCH EXISTING PAVEMENT MATERIAL AND THICKNESS L1/2" APPROVED EXCAVATED MATERIAL IN UNPAVED AREAS UNLESS OTHERWISE DIRECTED FOR FLEXIBLE PIPE WITH SOLID OF PROFILE WALLS, GRANULAR BEDDING MATERIAL SHALL BE PLACED AND HAND TAMPED IN 6" LAYERS TO A MINIMUM OF 1' -0" ABOVE PIPE. a BED PIPE IN SPECIFIED GRANULAR BEDDING MATERIAL HAND TAMPED IN 6" LAYERS TO 8 TO 12 INCHES ABOVE PIPE. BEDDING MATERIAL SHALL CONFORM TO INDOT 903.02, SIZE NO. 8 2 #4 BARS AT 28" LONG 6" MIN. (TY' NON- SHRINK GROUT MAXIMUM OPENING THAN 0.0. 4" GREATER OF PIPE EDGE OF PAVEMENT, CURB-/ GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT -OF -WAY #8 COMPALTED STONE 0 34" 22" 0 PLAN VIEW 0 LAn rAnAl ,9 CROSS SECTION PAVEMENT INLET TYPE "A" NOT TO SCALE LEGEND OD OUTSIDE DIAMETER ID INSIDE DIAMETER d DEPTH OF BEDDING MATERIAL BELOW PIPE 0 a N N a M IF WITHIN 5' OF EDGE OF PAVEMENT, USE "8" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY FOR ENTIRE TRENCH BACKFILL HEAVY DUTY LAMPHOLE CASTING W/ SOUD LID, NEENAH R-1974 OR EQUAL CONCRETE COLLAR N EENAH R -3405 (PAVED AREA) OR R- 3286 -8V (CURB) 'uilll/11i1•1x $2 Me' i n 4 DISTANCE DEFINED BY D.O.T. REQUIREMENT MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT DEPTH OF BEDDING MATERIAL BELOW PIPE REINFORCED CONCRETE PIPE (RCP) BEDDING/TRENCH DETAIL NOT TO SCALE COMPACTED SOIL BACKFILL I 6 "(TYP) 47/ OALlp (4""1 jayi Affefrt-Amoiviaglizer WYE 45' BEND 4" UNDERDRAIN NOTE: MAXIMUM CLEANOUT SPACING TO BE NO MORE THAN 100 FEET. 4 BARS AT v) 2 O.C., E.W. CLEANOUT DETAIL 6" COMPACTED #53 AGGREGATE NOT TO SCALE 0" MAX. IF NOT WITHIN 5' OF EDGE OF PAVEMENT: USE "B" BORROW COMPACTED TO 90% STANDARD PROCTOR DENSITY TO 1/6 OF PIPE DIAMETER AND REGULAR BACKFILL TO TOP OF TRENCH #8 STONE OR APPROVED EQUIVALENT BEDDING MATERIAL HAND TAMPED OR WALKED INTO PLACE. NOTES: 1. ALL INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED UFTS. 2. A MINIMUM 9" OF CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. FULL HEIGHT BUTYL RUBBER COATIN AS PER SPECIFICATION 6" MIN. STONE REQUIRED UNDER MANHOLE BASE FOR FINISH FLOOR LEVELING AND SUPPORT 4' MIN. SEE UTILITY PLAN FOR INVERTS FLEXIBLE PIPE SLEEVE PRECAST CONCRETE RINGS FINISH GRADE BISMATIC COATING OVER RISERS A 0 7 FILL WITH CONCRETE CAST IN PLACE OR PRECAST SANITARY SEWER BENCH SLOPE 1/2" PER FOOT STANDARD MANHOLE BENCHES NOT TO SCALE 4' -0" MIN. MANHOLE BASE FOR PRECAST SECTION A -A EENAH R -1642 W/SELF SEALING UD (OR EQUAL) 6' -0" DIA. FOR CAST IN PLACE SECTION A -A SANITARY MANHOLE DETAIL CLAY TOWNSHIP NOT TO SCALE CONCRETE GROUT BENCH SEWER MAIN SEWER MAI COMPACTED #53 STONE TAPERED CONE SECTION a 00 #4 12" EA. WAY %;%\<>/./\<//\</4<//,</' a 0 45' WYE FITTING I v 45' ELBOW ELEVATION LATERAL DETAIL NOT TO SCALE DATE: PLAN EXISTING GRADE 4J 0 LATERAL *It1�� r GLE /ss�, N O r PE 10 II 403858 STATE OF HIE it0 ♦'''j ccsS� ONA�ENG`��