Loading...
HomeMy WebLinkAboutBP1-C1.41 Grading/Utility Plan-WestCQPYRIG iT C h 2004 williams assocla es i ects, ltd. Schneider THE SCHNEIDER CORPORATION Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 -1037 Telephone: 317.826.7100 Fax: 317,826.7200 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering 1 1 111 111111 -c \AHND /q 1 11 No.10100357 O STATE OF 1 /a /ON E- Om' 0 (9 DATE. 8/20/04 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION COPYRIGHTED BY THE SCHNEIDER CORP- CARMEL CLAY PARKS RECREATION CENTRAL PARK MASS EARTHWORK BUILDING PADS CARMEL- INDIANA -46032 revised GRAPHIC NORTH TECTS PLANNERS rot Stream, Illinois 60188 Fax 630 221 -1220 J W U 07 acv CD H "CV O LL U a GRADING! UTILITY PLANIWEST B PI- C TSC JOB NO.: 2722.002 5:1 SLOP -Y. a WETLAND AREA TO REMAIN UNDISTURBED r t P. 9 ES TREEUNES MOVED IN ALL THIN THE CONSTRUCTION LIMITS UTILITIES Indiana Underground Utility Location Service (1 -800- 382 -5544) was contacted on 31 DEC 02 for marking of utilities on 3 JAN 02 confirmation #0100656780 -000 Water Carmel City Sewer and Water 130 1st Avenue SW Carmel, Indiana 46032 317 -571 -2648 Telephone Ameritech 220 North Meridian Street Indianapolis. Indiana 46204 317 265 -4878 Sanitary Sewer Clay Township Regional Waste 10755 North College Avenue Carmel, Indiana 46032 317- 844 -9200 Cable Time Warner Cable 516 East Carmel Drive Carmel, Indiana 46032 317 -848 -4726 Utility Hotline: within Indiana 1 -800- 382 -5544 outside Indiana 1- 800 428 -5200 Note The nature, size and location of utilities are per plans and locations provided by the respective utility companies. The above list constitutes some, if not all, of the utility companies which may provide service in the area of, and adjacent to, the subject project, based upon the information available through such plans and locations, and any incidental visual inspection. All utility companies should be notified prior to any excavation for field location of services and verification of size and nature of services. ASSUMED NORTH SCALE: 1 50 50 0 25 50 GRAPHIC SCALE 1 =50' Gas Vectren Energy Delivery 5: P.O. Box 1700 Noblesville, Indiana 46061 317 776 -5534 Electric Indpls. Power and Light Co. 2102 North Illinios Street Indianapolis, Indiana 46202 317 -261 -8406 100 5. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 8. ALL FILL AREAS SHALL BE COMPACTED TO AT LEAST 100 PERCENT OF THE MAXIMUM DRY DENSITY (ASTM D- 1557). II.,IECTIENTED 835 4. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 6. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES. 1000.001 ooa 2. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO THE PHASE OF WORK. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION FOR EACH UTILITY BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED. 7. REMOVE AND BACKFILL ALL AREAS WHERE ANY FIELD TILE CROSSES PROPOSED BUILDING PADS. ALL FIELD TILES INTERCEPTED TO BE PERPETUATED INTO STORM SEWER SYSTEM OR LAKE. THE SUBCONTRACTOR SHALL NOTIFY IN WRITING THE OWNER AND THE ENGINEER IN ANY CIRCUMSTANCES WHERE THIS CANNOT BE ACCOMPLISHED. CTIRATEDIDNT- 11 CC 1. ALL GRADES AT CONSTRUCTION LIMITS SHALL MEET EXISTING GRADES. 3. STANDARD SPECIFICATIONS FOR THE CLAY TOWNSHIP REGIONAL WASTE DISTRICT, INDIANA SHALL APPLY FOR ALL SANITARY SEWER AND STORM SEWERS. 9. ASPHALT TO BE PLACED UPON COMPLETION OF EARTH MOVING ACTIVITIES. 10. ALL TOPSOIL SHALL BE REMOVED TO A DEPTH OF 8 INCHES OR AS OTHERWISE INDICATED IN THE SOILS INVESTIGATION REPORT BEFORE REMAINING EARTHWORK ACTIVITIES COMMENCE. ONLY TOPSOIL CAPABLE OF BEING USED ON —SITE MAY BE STOCKPILED ON —SITE IN LOCATION DESIGNATED BY OWNER. ALL EXCESS TOPSOIL SHALL BE HAULED OFF —SITE AT NO ADDITIONAL COST TO OWNER. TOPSOIL STOCKPILES PLACED ON SITE SHALL BE TEMPORARILY SEEDED WITHIN THREE DAYS OF PILE COMPLETION. 11. RIP —RAP AT OUTLETS TO BE 6" TYPE C ROCK 18" DEEP. ROCK SIZE INDICATES THE SQARE OPENING ON WHICH 85% OF THE MATERIAL, BY WEIGHT, WILL BE RETAINED. WIDTH OF PROTECTION SHALL BE THE WIDTH OF THE FLARED END SECTION OR 4', WHICHEVER IS GREATER. LENGTH OF RIPRAP TO BE 6' FOR 12" 18" RCP AND 8' FOR 21" 27" RCP. HOLEY MOLEY SAYS DON'T DIG LINDY' "IT'S THE LAW'' CALL 2 WORKING DAYS BEFORE YOU DIG 1- 800 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IS -69 -1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. Existing Storm Sewer Existing Sanitary Sewer New Sanitary Sewer (Laterals are shown for reference only) Existing Storm Sewer Sanitary Structure Number Existing Contour Existing Elevation Proposed Contour Proposed Finish Grades Swale Flowline(E) Flow Arrow Utility Drainage Esmt. Existing Water Main Existing Fire Hydrant Existing Water Valve Existing Utility Pole Existing Trees Existing Fence ST STIR. a�C1C71J.GID�IE