HomeMy WebLinkAbout1134.96 P.O.P. Access Building Addition, Site Plan, pg. EPANEL 120 VOLTS CAA2 3 PHASE 4 WIRE 140 AMP MAIN BUS 100 AMP MAIN BREAKER OR NO. CIRCUIT DESCRIPTION CAR. BF AMP_ cc WIRE SIZE LOAD WITH ACRYUC LENS. 2 -32 WATT CW LAMPS, ENERGY SAVING, HIGH POWER FACTOR BALLASTS. CIR NO. CIRCUIT DESCR DESCRIPTION 1.) E BATTERY OPERATED SELF CONTAINED "EXIT" UGH T, RED LETTERS ON WHITE X FACE, UNIVERSAL MOUNTING. CHARGER TEST SWITCH. DUAL UTE FIX -2 -RW OR. BREAKER WIRE SIZE LOAD AMP POLE 1 1 20 1 12 112 AWG 2 10 2 20 1 12 15 3 3 GND 20 1 12 4 20 1 12 5 20 1 f 2 5 SPACE 6 20 1 12 6 7 20 1 12 8 SPACE 20 1 12 8 20 1 12 10 INTERRUPTING CAPACITY RATING 36000 AMPS RMS 20 1 12 11 20 1 12 12 20 1 12 13 20 1 12 14 20 1 12 15 20 1 12 16 20 1 12 17 20 1 12 18 20 1 12 20 1 12 420 20 i 12 LIGHT FIXTURE SCHEDULE 480 PANEL DP-2 3 AMP IA IA MS SURFACE MOUNTING WITH GROUND LUG 4 WIRE 200 AMP MAIN BREAKER !i!I OA 2'X4' MODULAR SURFACE STYLE FLUORESCENT FIXTURE WITH DIFFUSE LENS. 4 -32 WATT CW LAMPS, ENERGY SAVING, HIGH POWER FACTOR BALLASTS, MATH CHAIN MOUNTING. HUBBELL SURFACEUNE SSD3NA- E1 -PS2 SURFACE MOUNTED PORCELAIN KEYLESS INCANDESCENT FIXTURE SUITABLE OE:: FOR 100 WATT A -19 LAMP. 1'X4' WR APAROUND COMMERCI AL FLUORESCENT FIXTURE TRIP C WITH ACRYUC LENS. 2 -32 WATT CW LAMPS, ENERGY SAVING, HIGH POWER FACTOR BALLASTS. HUBBELL WIN 42- WAC -E1 D WALL MOUNTED EXTERIOR HIGH INTENSITY DISCHARGE FIXTURE. PROVIDE POL YC ARBON ATE LENS, DARK BRONZE FINISH, 1 -100 WATT HIGH PRESSURE SODIUM LAMP. HUBBELL PIA. 0100S -118 1.) E BATTERY OPERATED SELF CONTAINED "EXIT" UGH T, RED LETTERS ON WHITE X FACE, UNIVERSAL MOUNTING. CHARGER TEST SWITCH. DUAL UTE FIX -2 -RW DISTRIBUTION PANEL SCHEDULE 480 PANEL DP-2 3 AMP IA IA MS SURFACE MOUNTING WITH GROUND LUG 4 WIRE 200 AMP MAIN BREAKER !i!I LOAD DESCRIPTION BRANCH AMPS FEEDER SIZE POLE SIZE TRIP MIRE COND. KVA MNN INCOMING SERVICE 3 N/A 200 j4/C AK 3 GND 230 1 UNIT HEATER 3 12 15 112 AWG 3 GND 10 2 UNI HEATER 3 12 15 AIR 2 AWG 3 GND 10 3 SPACE 4 SPACE 5 SPACE 6 SPACE SPACE 8 SP ACE INTERRUPTING CAPACITY RATING 36000 AMPS RMS PHOTOCELL PANEL (h r r- I i 1 1- 1 f Li AWG IN� 3' RIGID CONDUIT F RE ALARM PANEL 7 1 804LD1N ALARM PANEL. EXISTING CAA1 EXISTING 1 0 EXISTING EXISTING S 11 (4) #1 AWG (1) #6 AWG IN 1 -1 /2' RIGID CONDUIT HEATER DISCONNECT /1 0 0 EXISTING NEW PARTIAL ELECTRICAL POWER PLAN SCALE: 1 /4 =1' -0" TO LP -1 CKT 30 PARTIAL LIGHTING PLAN SCALE: 1 /4" =1' TO LP -1 CK 32 PROJECT PROJECT EXISTING St -X PROVIDE 8 ADDITIONAL TYPE "C" FIXTURES. LOCATE PER OWNER. W/SWVEL HANGER, MOUNT O NEW BUILDING ADDITION 106 NEW BUILDING ADDITION 106 TODP 1 r r 0 X--- —X-- r aF x A_.....�l WX--_ r-3+E -X -X MOUNT FIXTURE W /ADJUS TABLE CH TO CHANNEL FITTING W/SWIVEL HANGER. MOUNT CHANNEL STRUT W/U -BOLT CLAMP TO BEAM. PLUG POWER CORD INTO ELECTRICAL ADAPTER SCREWED INTO SWITCHED PORCELAIN LAMP FIXTURE. PORCELAIN LAMP FI XTURE MOUNTED TO HEX BOX MOUNTED TO BEAM W/CHANNEL STRUT. (TYPICAL) 2 LAMPS IN EACH FIXTURE TO BE CONTROLLED BY EACH SWITCH. (TYPICAL) 0 1 1 1 100 AMP PDSC2 MAIN BREAKER 100 AMP PDSC MAIN BREAKER PROVIDE AND INSTALL PANELBOARD PDSC 2 4 -r AWG 1-#6 ANC GND IN 1 -1 /2" RIGID CONDUIT FUSED DISC SW REFUGE LUGS ON MAN BREAKER UNE SIDE TO AVCCOMODATE 2- 1 AVG PER PHASE DISCONNECT FEEDER TO PDSC AND I4STALL A 125 AMP FUSED DISCONNECT ON SECONDARY OF TRANSFORMER SWTCH. RECONNECT PDSC FEEDER CIRCUIT. PARTIAL ONE —LINE DI NOT TO SCALE 45 KVA DRY TYPE TRANSFORMER ,r. DP -1 REPLACE CABLE WITH 4 -14/0 4-0/o 1 -#4 GND IN 3" RIGID CONDUIT 4. FROM AUTO TRANSFER GEN 225 AMP DP -2 1387 KWh BID PETERSON SYMBOL LIST i ED FUSED DISCONNECT SWITCH. UNIT WALL HEATER MOUNTED 10' -0" AFF. ELECTRIC DISTRIBUTION PANEL (SEE SCHEDULES) /1/1 QUANTITY OF CONDUCTORS, #12 A# UNLESS NOTED 0THERVASE. WALL SWTCH, 3 -WAY WALL SWITCH MINIS $3 DUPLEX WALL RECEPTACLE MOUNTED 18' TIFF, NUMBER REFERS TO CIRCUIT AT PANEL SCALE 164 4 k P.G. 401 E. COLFAX A1.E. SUITE SOUTH BEND IN 48617 LIGHTING AND ELECTRICAL POWER CONSTRUCTION NOTES 0 0 ,2 13 RELOCATE ELECTRIC RECEPTACLE AND PHONE JACK FROM WAIL TO BE DEMOUSHCD AS SHOWN. REPLACE EXISTING FUSES IN MAIN DISCONNECT SWITCH WM1H 225 AMP, 480V, CLASS "R" FUSES. 2 -#12 AWG i -#12 A1MG GRN IV CONDUIT. ROUTE TO NEAREST ELECTRICAL RECEPTACLE AND TAP ON TO CIRCUIT I4DICATED. FUSED DISCONNECT SWTCH FOR UNIT HEATERS, MOUNT AT 64' TO OPERATING HANDLE. PROVIDE 15 AMP TYPE RK5 FUSES. ROUTE 3 -#12 AC COPPER CONDUCTORS AND 1 -112 AWG IN 3/4" CONDUIT TO DP -2. 4" CONDUIT CABLE ENTRANCE IN FOUNDATION AND FLOOR SLAB. REFER TO ARCHITECTURAL DETAIL. PROVIDE 02- GEDNEY TYPE CSBE SEAUNG BUSHING, SEGMENTED FOR 3 CABLES. 2 -#12 AVG WIRES At 1 -#12 AWG GRN IN CONDUIT. ROUTE ON INTERIOR SIDE OF WALL TO NEXT EXTERNAL FIXTURE MID TAP INTO CIRCUIT. SEAL ALL PENETRATIONS WEATHER TIGHT. INSTALL EXIT LAMP PERPENDICULAR TO WALL ABOVE DOOR. MIRE TO NEARBY EXIT LIGHTS AND TAP CIRCUIT (LP -1, CKT 33). LIRE INTO EXISTING PORCELAIN LAMP HOLDER CIRCUIT, TAP AT NEAREST EXISTING FIXTURE. PROVIDE AND INSTALL DP -2. TAP INTO UNE SIDE OF DP -1. SEE PARTIAL ONE -LINE DIAGRAM. PROWDE FUSED DISCONNECT ON SECONDARY OF PDSC TRANSFORMER. SEE PARTIAL ONE -UNE DIAGRAM. PROVIDE AND INSTALL CAA2. TAP INTO UNE SIDE OF CAA1. PROVIDE AND INSTALL ELECTRIC UNIT HEATER, ADJUST AIR FLOW TO PROVIDE CIRCULAR PATTERN. SEE UNIT HEATER SCHEDULE. REPLACE CABLE BETWEEN AUTO TRANSFER SWITCH AND DP -1 MATH 4 -/4/0 CABLE POWER CONDUCTORS. PETERSON ENGI AT&T PROJECT NUMBER CW CODE I DOCtJ1iENT OOK1ItOL. NUIt ABD5EO1 .DWG 1 FILE N� iaLor Nux� �oo� rw l cw l 1 ma s 880160 STATE o r ICHiTtt ERI ARCHITECTS ENGINEERS 252 N.W. EXECUTIVE WAY 401 E. COLFAX AVENUE LEE'S SUMMIT MO 64063 SOUTH BEND, IN 46617 (816) 525 -9480 (218) 233 -8270 CRMLINBV i AT&T PROPRIETARY USE PURSUANT TO COMPANY iN TRUC1IONS sterr NUMBER E01 10 P.O.P. ACCESS BUILDING ADDITION 410 GRADLE DRIVE CARMEL, IN 46032 UNIT HEATER SCHEDULE MARK NO. MANUFACTURER MODEL T OUTPUT BTUill ELECTRIC VOLT PHASE HERTZ UH#3 Q -MARK MUH -10 -4 UNIT 650 34100 480 3 60 UH 0-MARK MUH -10 -4 UNIT 650 34100 480 3 60 PRO WDE INTERNAL DISCONNECT SWATCH, UNIVERSAL MOUNTING BRACKET, AND INTERNAL THERMOSTAT. PHOTOCELL PANEL (h r r- I i 1 1- 1 f Li AWG IN� 3' RIGID CONDUIT F RE ALARM PANEL 7 1 804LD1N ALARM PANEL. EXISTING CAA1 EXISTING 1 0 EXISTING EXISTING S 11 (4) #1 AWG (1) #6 AWG IN 1 -1 /2' RIGID CONDUIT HEATER DISCONNECT /1 0 0 EXISTING NEW PARTIAL ELECTRICAL POWER PLAN SCALE: 1 /4 =1' -0" TO LP -1 CKT 30 PARTIAL LIGHTING PLAN SCALE: 1 /4" =1' TO LP -1 CK 32 PROJECT PROJECT EXISTING St -X PROVIDE 8 ADDITIONAL TYPE "C" FIXTURES. LOCATE PER OWNER. W/SWVEL HANGER, MOUNT O NEW BUILDING ADDITION 106 NEW BUILDING ADDITION 106 TODP 1 r r 0 X--- —X-- r aF x A_.....�l WX--_ r-3+E -X -X MOUNT FIXTURE W /ADJUS TABLE CH TO CHANNEL FITTING W/SWIVEL HANGER. MOUNT CHANNEL STRUT W/U -BOLT CLAMP TO BEAM. PLUG POWER CORD INTO ELECTRICAL ADAPTER SCREWED INTO SWITCHED PORCELAIN LAMP FIXTURE. PORCELAIN LAMP FI XTURE MOUNTED TO HEX BOX MOUNTED TO BEAM W/CHANNEL STRUT. (TYPICAL) 2 LAMPS IN EACH FIXTURE TO BE CONTROLLED BY EACH SWITCH. (TYPICAL) 0 1 1 1 100 AMP PDSC2 MAIN BREAKER 100 AMP PDSC MAIN BREAKER PROVIDE AND INSTALL PANELBOARD PDSC 2 4 -r AWG 1-#6 ANC GND IN 1 -1 /2" RIGID CONDUIT FUSED DISC SW REFUGE LUGS ON MAN BREAKER UNE SIDE TO AVCCOMODATE 2- 1 AVG PER PHASE DISCONNECT FEEDER TO PDSC AND I4STALL A 125 AMP FUSED DISCONNECT ON SECONDARY OF TRANSFORMER SWTCH. RECONNECT PDSC FEEDER CIRCUIT. PARTIAL ONE —LINE DI NOT TO SCALE 45 KVA DRY TYPE TRANSFORMER ,r. DP -1 REPLACE CABLE WITH 4 -14/0 4-0/o 1 -#4 GND IN 3" RIGID CONDUIT 4. FROM AUTO TRANSFER GEN 225 AMP DP -2 1387 KWh BID PETERSON SYMBOL LIST i ED FUSED DISCONNECT SWITCH. UNIT WALL HEATER MOUNTED 10' -0" AFF. ELECTRIC DISTRIBUTION PANEL (SEE SCHEDULES) /1/1 QUANTITY OF CONDUCTORS, #12 A# UNLESS NOTED 0THERVASE. WALL SWTCH, 3 -WAY WALL SWITCH MINIS $3 DUPLEX WALL RECEPTACLE MOUNTED 18' TIFF, NUMBER REFERS TO CIRCUIT AT PANEL SCALE 164 4 k P.G. 401 E. COLFAX A1.E. SUITE SOUTH BEND IN 48617 LIGHTING AND ELECTRICAL POWER CONSTRUCTION NOTES 0 0 ,2 13 RELOCATE ELECTRIC RECEPTACLE AND PHONE JACK FROM WAIL TO BE DEMOUSHCD AS SHOWN. REPLACE EXISTING FUSES IN MAIN DISCONNECT SWITCH WM1H 225 AMP, 480V, CLASS "R" FUSES. 2 -#12 AWG i -#12 A1MG GRN IV CONDUIT. ROUTE TO NEAREST ELECTRICAL RECEPTACLE AND TAP ON TO CIRCUIT I4DICATED. FUSED DISCONNECT SWTCH FOR UNIT HEATERS, MOUNT AT 64' TO OPERATING HANDLE. PROVIDE 15 AMP TYPE RK5 FUSES. ROUTE 3 -#12 AC COPPER CONDUCTORS AND 1 -112 AWG IN 3/4" CONDUIT TO DP -2. 4" CONDUIT CABLE ENTRANCE IN FOUNDATION AND FLOOR SLAB. REFER TO ARCHITECTURAL DETAIL. PROVIDE 02- GEDNEY TYPE CSBE SEAUNG BUSHING, SEGMENTED FOR 3 CABLES. 2 -#12 AVG WIRES At 1 -#12 AWG GRN IN CONDUIT. ROUTE ON INTERIOR SIDE OF WALL TO NEXT EXTERNAL FIXTURE MID TAP INTO CIRCUIT. SEAL ALL PENETRATIONS WEATHER TIGHT. INSTALL EXIT LAMP PERPENDICULAR TO WALL ABOVE DOOR. MIRE TO NEARBY EXIT LIGHTS AND TAP CIRCUIT (LP -1, CKT 33). LIRE INTO EXISTING PORCELAIN LAMP HOLDER CIRCUIT, TAP AT NEAREST EXISTING FIXTURE. PROVIDE AND INSTALL DP -2. TAP INTO UNE SIDE OF DP -1. SEE PARTIAL ONE -LINE DIAGRAM. PROWDE FUSED DISCONNECT ON SECONDARY OF PDSC TRANSFORMER. SEE PARTIAL ONE -UNE DIAGRAM. PROVIDE AND INSTALL CAA2. TAP INTO UNE SIDE OF CAA1. PROVIDE AND INSTALL ELECTRIC UNIT HEATER, ADJUST AIR FLOW TO PROVIDE CIRCULAR PATTERN. SEE UNIT HEATER SCHEDULE. REPLACE CABLE BETWEEN AUTO TRANSFER SWITCH AND DP -1 MATH 4 -/4/0 CABLE POWER CONDUCTORS. PETERSON ENGI AT&T PROJECT NUMBER CW CODE I DOCtJ1iENT OOK1ItOL. NUIt ABD5EO1 .DWG 1 FILE N� iaLor Nux� �oo� rw l cw l 1 ma s 880160 STATE o r ICHiTtt ERI ARCHITECTS ENGINEERS 252 N.W. EXECUTIVE WAY 401 E. COLFAX AVENUE LEE'S SUMMIT MO 64063 SOUTH BEND, IN 46617 (816) 525 -9480 (218) 233 -8270 CRMLINBV i AT&T PROPRIETARY USE PURSUANT TO COMPANY iN TRUC1IONS sterr NUMBER E01 10 P.O.P. ACCESS BUILDING ADDITION 410 GRADLE DRIVE CARMEL, IN 46032