HomeMy WebLinkAbout1134.96 P.O.P. Access Building Addition, Site Plan, pg. Fn r r-. n ""_T"_ n n n T. n n 1'[ l x x �f r 2 p( 2 x 2 -3 4' if I I* L L i 1 1 1 w 1a 1R a 0 1 I1 4 0 }IRE ALARM PANEL 0 1 f r MANUAL PULL STATION z. PULL 214D CIRCUIT WIRE 1 10 EXISTING 1-9 PARTIAL ALARM SECURITY PLAN SCALE: 1 /4' G..) 1 2 -1 EXISTING I ORN IN biESLL Rte AUX GROUND. BUS 0 0 RELOCATE END -OF -UNE DEVICE FROM HORN IN DIESEL ROOM 4/0 COPPER GROUND W/ GREEN JACKET TO OPGP BUS X X X STROBE HORN PARTIAL GROUNDING PLAN SCALE: 1/4• =1•-U" RELOCATE END -OF -UNE DEVICE FROM MANUAL PULL STATION 1 -1 i� 0 0 1 -14 P X X X X X x x it X X `1 x X P I I 1 1 1 1 i !1 AUX GROUND BUS --A 1 .J 0 O P P P 1 -14 ©1 MONITORING SWITCH, NORMALLY CLOSED SMOKE SENSOR; PHOTOELECTRIC TYPE SMOKE SENSOR; IONIZATION TYPE FIRE MANUAL PULL STATION, DUAL ACTION FIRE STROBE HORN ALARM SECURITY PLAN NOTES 0 0 0 0 COORDINATE INSTALLATION OF MAGNETIC SWITCH AND BOLT MONITOR WITH DOOR MANUFACTURER. PROVIDE AND INSTALL NEW PHOTOELECTRIC AND IONIZATION SMOKE DETECTORS IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS IN THE APPROXIMATE LOCATION SHOWN. INSTALL AS CLOSE TO CEIUNG AS POSSIBLE. EXTEND WRING TO EXISTING DETECTOR. 2 -/16 AWG DETECTIOR CIRCUIT WIRES AND 2 -#14 AWG HORN CIRCUIT IN 1/2" EMT. 2 -/14 AWG DOOR SECURITY SIGNAL. WIRES (1 -PAIR) IN 1/2' CONDUIT. ROUTE TO EXISTING DOOR CONTACTS AND WIRE IN SERIES. GROUNDING PLAN NOTES O O 0 0 0 0 0 0 ,o EXISTING /2 GROUND BONDED TO FLOOR AND FOUNDATION REINFORCEMENT. DO NOT CUT. 5/8" DIA. 10' -0" LONG GROUND ROD. TOP OF GROUND ROO DRIVEN 36' BELOW GRADE. 16' SPACING BETWEEN RODS. EXCAVATE BY HAND TO LOCATE EXISTING GROUND RING. CADWELD NEW /2 SOUD, TINNED COPPER GROUND TO EXTEND RING AROUND PERIMETER OF BUILDING ADDITION. SUT A LENGTH OF 1' PVC PIPE, SUP OVER GROUND RING TO PROVIDE A SLEEVE THROUGH FOUNDATION. PROVIDE AUX. GROUND BUS, 1' -6 "X3 "X1/4" COPPER BAR MOUNTED AT 1 /6 SOUD, TINNED COPPER GROUNDING CONDUCTOR CADWELD TO BURIED RING, 2 HOLE, LONG BARREL COMPRESSION LUG, BOND DOOR FRAMES, GUTTERS, AND DOWNSPOUTS, AND METAL APPURTANCES ON SIDE OF BUILDING. 6 SOUD, TINNED COPPER GROUNDING CONDUCTOR. CADWELD TO BURIED RING, 2 HOLE, LONG BARREL COMPRESSION LUG, BOND TO ROOF STEEL FRAME MEMBERS. /6 SOUD, TINNED COPPER GROUNDING CONDUCTOR. CANED TO BOND FLOOR AND FOOTING REINFORCEMENT TO GROUND RING. SOUD, TINNED COPPER GROUNDING CONDUCTOR CADWELD TO BURIED RING. BOND COPING, GUTTER, AND DOWNSPOUT. /6 STRANDED, COPPER GROUNDING CONDUCTOR TO BURNDY TYPE GAR PIPE GROUND CONDUCTOR. GROUND TO AUX. BUS. SYMBOL LIST f f BOLT MONITOR BUILDING ADDITION REAR ENTRANCE ELASTIC STANDOFF INSULATOR #1872 -3F INC. INSTALLED BY CONTRACTOR. THREAD ONTO 5/8" ROD TIGHT TO WALL 5/8" CADMIUM PLATED BOLTS AND LOCKWASHERS 1/4" X 3" COPPER GROUND BUS SCALE 1 /4" EXISTING DOOR SW TCHES BOLT MONITOR BUILDING ADDITION CAA ENTRANCE 0 OCD EXISTING DOOR SW TCHES DOOR SECURITY WIRING DIAGRAM NOT TO SCALE COLUMN O 0 O 0 (2) 5/8" DIA. MOUNTING HOLES 1' 6" DOOR SWTICH BUILDING ADDITION CAA ENTRANCE DOOR SWITCH BUILDING ADDITION REAR ENTRANCE 6 -7/8" 6 GROUND BUS DETAIL NOT TO SCALE iI/IIlf/l/II'IIi GROUND BUS MOUNTING DETAIL NOT TO SCALE ARCHITECTS 252 N.W. EXECiaVe WAY LEE'S SUMMIT, MO 64063 (816) 525-9480 1 3-1/8" 0 0 0 r OdJA1ENT OONIROL NUMBER (8) 3/8" DIA. HOLES TO MAIN ENTRANCE DOOR SWTCHES. WIRE IN SERIES WITH MAIN ENTRANCE. TO REAR ENTRANCE DOOR SWITCHES, WE IN SERIES WITH 4 OTHER AT&T DOORS. INSERT 5/8" THREADED ROD, ALLOW TO PROTRUDE 5/8" TO 11/16" FROM MOUNT INS SURFACE 5/8" EXPANSION ANCHOR 2 PLACES PETERSON ENGI AT &T PROJECT NUMBUt i�E NNE PLOT NUMBER 80011 NUMBER ABD5EO2.DW 1 a 1 Ji EE RI G ENGINEERS CLU CODE CRMLINBV AT &T PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTIONS SHEET NUMBER E02 401 E. COLFAX AVENUE 10 SOUTH BEND, IN 46617 (218) 233 -8270 P.O.P. ACCESS BUILDING ADDITION 410 GRADLE DRIVE CARMEL, IN 46032