HomeMy WebLinkAbout04090018-22V St Vincent Med Ofc, Development Plan pg. BEXISTING
STORM PIPE
INVERT 897.10
24" C.M.P.
EXISTING GAS MAIN
EXISTING
STORM PIPE
INVERT 896.75
24" C.M.P.
EXISTING
16" A WATER
MAI N
BURRED
TELEPHONE
CABLE
EXISTING
WESTON POINTE
SUBDIVISION
EXISTING
OVERHEAD
ELECTRICAL
EXISTING
STORM INLET
T.C.= 898.38
INVERT= 896.56
15" R.C.P.
EXISTING
SANITARY
T.C.= 898.99
EXISTING
LIGHT POLE
EXISTING 8"
SANITARY SEWER
EXISTING WATER MAIN
EXISTING
MARSH SUPERMARKET
EXISTING
THE VILLAGE AT WESTON PLACE
SUBDIVISION
INSTR NO. 9609626949
P.C. #1, SLIDE #686
EXISTING GAS MAIN
0 25 50 100
NOTE:
THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION
AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE
UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER
IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE
UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH
HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE
INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND
UTILITIES.
H.C.S.R.
GRAPHIC SCALE
IN FEET
1 inch 50 ft.
LEGEND
FLOW LINE
BURIED ELECTRIC LINE
OVERHEAD ELECTRIC LINES
BURIED TELEPHONE LINE
TELEPHONE LINE
BURIED CABLE T V. LINE
CABLE T V LINE
GAS LINE
WATER LINE
SANITARY SEWER LINE, MANHOLE
SANITARY CLEANOUT
STORM SEWER LINE, MANHOLE ENDSECTION
CURB INLET
BEEHIVE OR ROUND INLET
SQUARE FLAT INLET
FENCE LINE
SET PK NAIL UNLESS OTHERWISE NOTED
SET CAPPED REBAR STAMPED S &A FIRM 0008
HAMILTON COUNTY SURVEYOR'S RECORD
0
M.B.
"HOLEY MOLEY"
SAYS:
1 800 382 -5544
CALL TOLL FREE
1 800 -428 -5200
FOR CALLS OUTSIDE OF INDIANA
,O 11111 1 11114 I
R I NCC
�P OSTE i
'Qti O�
No.
10200495
14\ STATE OF c
'ONAL�N
1111111
200
POWER POLE
LIGHT POLE
ELECT TRANSFORMER
ELECT PEDESTAL
ELECT METER
GUY WIRE
TELEPHONE POLE
TELEPHONE PEDESTAL
TELEPHONE MANHOLE
CABLE T V POLE
CABLE T.V PEDESTAL
TRAFFIC SIGNAL POLE
TRAFFIC MANHOLE
TRAFFIC CONTROL BOX
GAS VALVE
GAS METER
WATER METER
WATER VALVE
FIRE HYDRANT
MAILBOX
CAUTION
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GF ,_,ND EVIDENCE (including,
but not limited to, manholes, inlets, valves,
marks made upon the ground by others AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILIITIES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
r
m
Z
0
0
N)
N
cki
Z
0
0
z
00
r
V
Z
1 1
X
W
rn CL
0
C C C
JOB NO. 49335
0
w o
0
SHEET NO.
C10
OF SHEETS