HomeMy WebLinkAbout04090018-22V St Vincent Med Ofc, Development Plan pg. DSTORM SEWER INFORMATION STR. NO. T.C. INVERTS DIR. 679 SEE �N 898.99 897.10 E 680 M.H. 899.60 897.34 W 668 INLET 901.50 898.73 N NE 669 M 901.40 898.95 SW 677 INLET 910.50 893.99 E 678 M. 1I. 901.20 898.67 E 676 INLET 901.60 898.59 SW W N 675 1NLE1 901.30 898.02 S 673 INLET 900.80 898.01 N 667 INLET 901.30 898.08 S W NE 670 SECTION 900.30 E 672 INLET 900.60 897.82 S N 674 SECTION 897.61 S 671 S CTION 897.61 S 666 SECT .ON 897.61 SW 663 SECION 897.61 W 664 INLET 903.30 900.17 E W 665 SECT oN 900.30 E 654 SECTION 897.61 W 655 M 898.20 897.09 NW 656 S CND 896.91 SE 657 SECTION 900.20 S 658 M.H. 902.48 900.23 S W 659 INLET 903.10 900.28 E 660 SEC I I END ON 900.63 S 661 M.H. 902.90 900.66 S NW 662 INLET 903.20 900.72 SE SANITARY SEWER INFORMATION STR. NO. T.C. INVERTS DIR. 200 1;4 A MLE 898.99 880.35 N 201 M.H. 899.70 880.83 880.93 S N 202 INLET 900.90 882.28 882.38 S N 203 M.Ii. 901.00 883.73 883.83 S N 204 INLET 900.70 884.91 5 EXISTING `24" C.M.P. POND #1 37.816 sq.ft. N.P.= 897.61 100 YR. ELEV. 900.2 BOTTOM ELEVATION 889.61 TOP OF BANK =902.2 tct 41,168 sq.ft. a F.F. ELEV.= 903.7 PAD ELEV. 903.0 0.45% 8" S.D.R. 35 PVC 883.83 PROPOSED GRADE 883.73 0.45% EXISTING GRADE 8" S.D.R. 35 PVC 882.38 0.45% 8" S.D.R. 35 PVC 880.83 107 L.F. 0.45% 8" S.D.R. 35 PVC O EX. SANI T.G.= 898. INVERT= 880.35 50 INLET C.= 898.38 INVERT 896.56 15" R.C.P. 05` 900 0 V) 0 wo 00 0 Q N II Z IY Q SCALE: r=50' HOR. 1 VERT. EARTHWORK: 1. EXCAVATION FORM \EARTHWRK 1848.01 84 PROPOSED PROPOSED PROPOSED PROPOSED PROPOSED W PROPOSED S <000 T LEGEND EXISTING SPOT ELEVATION EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING WATER i PROPOSED SUB SURFACE DRAIN (SSD) PROPOSED TRANSFORMER LOCATION yY 0 F.H. FIRE HYDRANT GRADE CONTOUR SANITARY SEWER STORM SEWER SWALE WATER 0 A. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus excavated material not required shall be removed from the site. B. Provide and place any additional fill material from offsite as may be necessary to produce the grades required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the source approved by the Developer. It will be the responsibility of the Contractor for any costs for fill needed. 2. REMOVAL OF TREES A. All trees and stumps shall be removed from areas to be occupied by a road surface or structure area. Trees and stumps shall not be buried on site. 25 3. PROTECTION OF TREES A. The Contractor shall, at the direction of the Developer, endeavor to save and protect trees of value and worth which do not impair construction of improvements as designed. B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with respect to protective measure to be taken, if any, to preserve such trees. 5. UTILITIES A. Rules and regulation governing the respective utility shall be observed in executing all work under this section. B. It shall be the responsibility of the Contractor to determine the location of existing underground utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free 1- 800 382 -5544 within Indiana or 1- 800 428 -5200 outside Indiana. 6. SITE GRADING A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area to subgrade as shown on the drawing. B. The tolerance for paved areas shall not exceed 0.10 feet above established subgrade. All other areas shall not exceed 0.10 feet plus or minus the established grade. Provide roundings at top and bottom of banks and other breaks in grade. C. The Engineer shall be notified when the Contractor has reached the tolerance as stated above, so that field measurements and spot elevations can be verified by the Engineer. The Contractor shall not remove his equipment from the site until the Engineer has verified that the job meets the above tolerance. D. All computed areas of structural fill material must be tested to assure minimum 95% of the maximum dry density using the standard proctor test method. 50 4. REMOVAL OF TOPSOIL A. All topsoil shall be removed from all areas beneath future pavements or building. Topsoil removal shall be to a minimum depth of 6 inches or to the depth indicated in the geotechmical report provided by the Developer to be excavated or filled. Topsoil should be stored at a location where it will not interfere with construction operations. The topsoil shall be free of debris and stones. GRAPHIC SCALE 100 IN FEET 1 inch 50 ft. "HOLEY MOLEY" SAYS: 1- 800 382 -5544 CALL TOLL FREE 1- 800 -428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION rn 0 o. O O 0 cc 0 11 IIII III ij No. 10200495 S. -o S TATE OF t eN 200 LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. 900 890 r C Z 0 m Ch U m z W (f) Q a 0 N rn 0 N) N SHEET NO. C10 OF SHEETS JOB NO. 49335 0 U 0 rn