Loading...
HomeMy WebLinkAboutA6.1 REFLEC CEILING-ELECTRICAL PLANS.PDF Project Number: Sheet Title: Issue Date: Sheet Number: Project: CARMEL, INDIANA 46032 By: Architect: Architecture /Project Managment: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) TRADE SOURCE Print Date Drawn By Checked By Revisions:200 SOUTH RANGE LINE ROAD SUITE 219 INDIANA DESIGN CENTER A6.1 REFLEC CEILING/ELECTRICAL PLANS Parcel 12 PEDCOR DESIGN GROUP, LLC PLAN NORTH 4/29/09 CONSTRUCTION DOCUMENTS1 A E G M 11 5 THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2006, 2007, 2008, JAMES R. STUTZMAN, AIA, CARMEL. 4/27/09 BID SET 11 G E A M 5 1 PLAN NORTH KEY PLAN SCALE: N.T.S. 1 A4.4 3 A4.4 3'-0" 5'-6 1/2" 5'-6 1/2" 7'-4 1/8" 4'-0" 9'-0" 7'-6" DN B B B CP3 B B B B CP3 I B B I CP3 E B CP3 FFCP1 F CP4 FFF FFF FFF B D CP6 B B D D D D D H H H H H H H H CP4 CP4 A A A A A AA A A A A A A A A C A C C1 C C1 A A A NL CP4 NL A NL NL NL C C1 NL A G CP5 CP7 COF DOORS A A1 A1 L CP7 CP7 CP7CP7 H CP7 H H HH A NL A1 NL J J J J J J J J J J J J K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K K H G A CP2 J K TYP. CP7 H .6 .5 1563 2.9 24 3.8 3.3 SUSPENDED CEILING HEIGHT IS 11'-0" A.F.F. UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. ALL WALLS GO TO DECK ABOVE UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: CEILING PLAN NOTES: LOCATE NEW SMOKE DETECTORS DUE TO LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGNBUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. CP1 NEW DRYWALL BULKHEAD. 7. 6. 5. 4. 1. 2. 3. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. NLD3 EMERGENCY/NIGHTLIGHT LOCATION. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. GYPSUM BOARD BULKHEAD. NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM. REFLECTED CEILING LEGEND: CP2 SHOWROOM LIGHTING CONTROLS. ALIGN AND STACK CONTROLS AS NEEDED. CP3 GRID CEILING SYSTEM WITH 2X4 LAY-IN LIGHT FIXTURE. SEE FINISH LEGEND AC1 FOR SPECIFICATIONS. CP4 OPEN EXPOSED CEILING WITH SUSPENDED LIGHT FIXTURES. CP5 EXISTING DRYWALL BULKHEAD WITH RECESSED DOWNLIGHTS. CP6 GRID CEILING SYSTEM WITH 2X4 LAY-IN LIGHT FIXTURE AND RECESSED DOWNLIGHT. SEE FINISH LEGEND AC1 FOR SPECIFICATIONS. CP7 ARMSTRONG INFUSION PANELS. SEE A4.4 FOR DETAILS. SYMBOL TYPE D LIGHT FIXTURE SCHEDULE RECESSED DOWNLIGHT/CONFERENCE ROOM MODEL DMF LIGHTING, DHIV-6-D6261SF-C W/DIMMER AND W/A-21 35OOK INCANDESCENT LAMP. DESCRIPTION WATTAGE MOUNTING HEIGHT NOTES 150W CEILING A SUSPENDED LIGHT FIXTURE/SHOWROOM LA LIGHTING, LCD936-2-8MT-SL-4E5H-UNV. WITH (4) T5HO 3500K FLUORSCENT LAMPS. 54W 12'-0" A.F.F. B 2X4 FLUORESCENT LAY-IN/OFFICES METALUX, 2P2GX-332538I-UNV-EB81. WITH (3) T8 3500K FLUORSCENT LAMPS. 32W CEILING C SUSPENDED LIGHT FIXTURE/MEMO ROOM LA LIGHTING, IND100-1-8RT-2E81H-UNV. WITH (2) T8 3500K FLUORSCENT LAMPS. 32W 12'-0" A.F.F. E WALL SCONCE/RESTROOM HUBBARDTON FORGE, #207873-19-B155 WITH (3) G-9 LAMPS. 60W 6'-9" A.F.F. F PENDANT LIGHT FIXTURE/KITCHEN 10'-0" 0" A.F.F. G PENDANT LIGHT FIXTURE/RECEPTION AREA LBL LIGHTING, CK-FJMULTI-SC W/(7) HS452-OPSC-1B-50-FSJ WITH (7) GY6.35 LAMPS. 50W VARIES H WALL SCONCE/ACCENT COLUMNS HUBBARDTON FORGE, #204670-19-STONE WITH (1) A-19 3500K LAMP. 75W 5'-0" A.F.F. I TASK LIGHTING/OFFICES ALICO LIGHTING, ZEELINE, ZL017RSF. WITH 120V WEDGE BASE XENON. 25W UNDERCABINET SEE ENLARGED PLAN 1/A4.4. TO BOTTOM OF MOUNTING PLATE. A1 SUSPENDED LIGHT FIXTURE/SHOWROOM 54W 12'-0" A.F.F. C1 SUSPENDED LIGHT FIXTURE/MEMO ROOM 32W 12'-0" A.F.F. LA LIGHTING, LCD936-2-4M-SL-2E5H-UNV. WITH (2) T5HO 3500K FLUORSCENT LAMPS. MOUNT W/Y-TOGGLE END/CABLE SUSPENSION #YTC58. CENTER WITHIN STRUCTURAL FRAMING. MOUNT W/Y-TOGGLE END/CABLE SUSPENSION #YTC58. CENTER WITHIN STRUCTURAL FRAMING. LA LIGHTING, IND100-1-4RH-1E81H-UNV. WITH (1) T8 3500K FLUORSCENT LAMPS. 60W ALICO, FORMA DRUM, #PS9550-30-30 WITH A19 LAMPS. J WALL MOUNTED UPLIGHT/CLERESTORY ELLIPTIPAR, ENSOUCE STYLE 403. M403150GW00X000. ESB020000, METAL HAILDE WALL MOUNTED UPLIGHT, W/T6 METAL HALIDE LAMP. 150W 11'-6" TO BOTTOM OF FIXTURE K PENDANT FIXTURE/CLERESTORY DMF LIGHTING, #DP609-F-42-W-SPC, PENDANT FIXTURE W/GX24Q COMPACT FLUORESCENT LAMP. 42W 20'-0" TO BOTTOM OF FIXTURE R DN EP3 +44" GFI +44" EP2 GFI EP5 EP4 EP4J +48" GFI +38" +38" EP1 +38" +38" +38" +38" +38" +38" +54" +54" EP3 D J .6 .5 1563 2.9 24 3.8 3.3 GENERAL ELECTRICAL/DATA NOTES: PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS FLUSH MOUNTED. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT UNLESS OTHERWISE INDICATED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @18" AFF UNLESS NOTED OTHERWISE. 5. 6. 7. 4. 3. 2. 1. COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP1 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP2 DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET. D ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +54" HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. FLUSH FLOOR MOUNTED OUTLET W/DUPLEX ELECTRICAL AND (4) VOICE DATA OUTLETS. EP3 EXISTING ELECTRICAL PANEL LOCATION. PROVIDE AND INSTALL POWER FOR DISHWASHER AND ICEMAKER. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER MANUAL. EP4 PROVIDE AND INSTALL POWER FOR GARBAGE DISPOSAL. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER MANUAL. EP5 J ELECTRICAL JUNCTION BOX. SCALE: 3/32" = 1'-0" 1 REFLECTED CEILING PLAN A6.1 SCALE: 3/32" = 1'-0" 1 ELECTRICAL/DATA PLAN A6.1 !"#"$ %"&"