Loading...
HomeMy WebLinkAbout04080060 116th Street Center, Site Construction Plans pg. 04w w uCt I. 0 E w EXISTING SPOT ELEVATION CONTOUR MANHOLE /INLET INLET PIPE END SECTION AREA /STREET LIGHT TELEPHONE RISER ELECTRIC RISER UNDERGROUND TELEPHONE UNDERGROUND ELECTRIC WATER LINE WATER VALVE FIRE HYDRANT WATER METER GAS LINE GAS VALVE GAS METER DECIDUOUS TREE /BUSH EVERGREEN TREE /BUSH TREE /SHRUB LINE NOTES: LEGEND= ELEC UTILITY COMPANIES: SBC AMERITECH CINERGY PUBLIC SERVICE OF INDIANA CLAY REGIONAL WASTE (SANITARY SEWER) CARMEL WATER COMPANY VECTREN PROPOSED SANITARY SEWER SANITARY SEWER CLEANOUT STORM SEWER STORM INLET ELECTRIC SERVICE LINE UNDERDRAIN WATER MAIN WATER SERVICE FIRE HYDRANT WATER VALVE 2. SEE MECHANICAL PLANS FOR LOCATION AND SIZE OF SANITARY DRAINS, WATER LINES AND FIRE PROTECTION WITHIN BUILDINGS. 3. PLUMBING CONTRACTOR TO VERIFY WATER PRESSURES. WATER SERVICE SIZE AND METER SUBJECT TO REVIEW AND REFINEMENT. FINAL WATER SERVICE SIZE AND METER SIZE TO BE DETERMINED BY PLUMBING CONTRACTOR /ARCHITECT. 4. COMPACTED GRANULAR BACKFILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 5. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE ALL MAINS, CONDUITS, SERVICE LINES, ETC., IN THE AFFECTED CONSTRUCTION AREA. EXISTING UTILITY STRUCTURES ARE SHOWN HERE IN ACCORDANCE WITH AVAILABLE INFORMATION. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES AND FACILITIES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY) IS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 6. RCP REINFORCED CONCRETE PIPE CLASS III PVC POLYVINYL CHLORIDE SANITARY SEWER ASTM D-3034, SDR -35 HCSP HELICAL CORRUGATED STEEL PIPE 16 GAUGE ALUMINIZED HDPE CORRUGATED HIGH DENSITY POLYETHYLENE PIPE (SMOOTH FLOW) 7. FLEXIBLE PIPE TO BE INSTALLED PER ASTM D -2321, CLASS 1,2, OR 3 BEDDING. RIGID PIPE TO BE INSTALLED PER ASTM C -12. 8. 10 LINEAL FEET OF 4" SUBSURFACE OTHERWISE A NOTED ON PLANS). WAY (UPGRADE) FROM ALL STORM INLETS (UNLESS 9. FOR SITE DETAILS SEE SHEETS "C801", "C802" AND "C803". 10. FOR SITE SPECIFICATIONS SEE SHEET "C901". 11. FOR SOIL EROSION AND CONTROL DATA SEE SHEET "C803 12. ALL CONSTRUCTION WITHIN PUBLIC RIGHT -OF -WAY SHALL BE PERFORMED IN ACCORDANCE WITH CURRENT CITY OF CARMEL STANDARD SPECIFICATIONS, LATEST EDITION. 13. SEE MECHANICAL /PLUMBING PLANS FOR SIZE OF DOMESTIC AND FIRE PROTECTION WATER LINES. 14. PROPOSED 12" WATERLINE BY CARMEL UTILITIES TO BE INSTALLED ON THE RIGHT -OF -WAY LINES. CD (E) INV. 83 56 AS Ceti IBET TYPE A --MCO W/ r W Nei R- 3286 -8V 7 1 L E_ "I TC 850.E (SE) INV. 844.56 gi SW) INV. 844.56 TYPE I CLEAN OUT TC. 853.3 INV. ELEV. 847. 10' BUIL1s11NG UNE AH R -1 72 -C TC 851.70 (SE) INV. 843.86 (NW) -INV: 843;86 CONTRACTOR SHALL RELOCATE ALL EXISTING UTILITIES ON SITE W/ 3b1 LF 8 I .1=r 61_ ism FLOOR IN LET TYPE E g I NEENAH R-3286- (E) INV. 843.20 FINISHED FLOOR ELEV. 853.50 STORMTEC ISLAND (WEST) STORMTECH UNDERGROUND STORAGI 29 ROWS x 12 CHAMBERS (1469') AN 9 R WS x 4 CI-IAMBERp (45x.5,0`) B01 OI OF UNI` 8 3.50 2 R F1_0(.1) EIi 43.8 10 r FLOOD ELEV. 844."1 OC YR, FLOOD EL. V. 846: 2 PROPO TC 851. 0 (W) IN 842.49 (S) INV 842.39 PROPOSED SW MH: T 20 (N) I V. 838.93 V. 840.83 .72 LF 8" PVC 0.45% INLET TYPE 'A -MOD` WI TC 848.60 INV. 84545 INLET E NEENAH R 281 TC 848.60 (N) INV.: 18 (E) INV. 844.93 U u LLLLU_LLLI_,11U U _U1111LI 11U_... K,;,, INLET TYPE NEENAH R- TC 847.80 (E) INV. TYPE I CLEAN OUT TC. 853.5 INV. ELEV. 847.00 (W) INV. 83$.51 TC 849.9' o It�V BUILT ".P TC 850ROPOSED .50 SAN MH. 4= L S INV 840.09 NEENAH R-37 50 NET 1WE W/ S T R E. Im_ r E r NEENAH R -3750 TC 847.50 +j84 2__ 8w INV S4? 1Fil 1! �W) INV 84274 Y. 84200 0 INV. 842.74 A -µ0D W/ 288 -8V TYPE I CLEAN OUT TC. 851.0 INV. ELEV. 845.00 PVC (0 0.45% 504 A MOD" W/ R -37 TC .00 (S) IN 844.1 TYPE I CLEAN OUT TC. 851.0 INV. ELEV. 845 _PROPQSFD SAM...fd�... TC 849.60 _N INV. :'N I (w) INV. SHED FLOOR 851.50 154 PVC VI 0.45% STREE T "B" nnnnnn.n_nr STORMTEC ISLAND (EAST) STORMTECH UNDERGROUND STORAGE 19 ROWS x 11 CHAMBERS (91'x8O') BO OM UNI 8 2.95 2 FL E. 10 FL ETV. =:3.7 00 FL E V. 844. 1 IN. 84 IN 84185 FINISHED FLOOR ELEV. 851.50 fl.4 a I TC 8 0 SAN I (E) INV. 839.17 (W) INV. 839.07 'S'SO 4sso� 17_1717-1_ .Th REVISIONS NORTH SCALE: 1 30' DRAWING: 2308203 DATE: 08/18/04 PROJ. NO.: 2308 DRAWN BY: cE SHEET NO.: yUBE FILE I 11 ii I ll I I I I I IN 1 1 11 II 1 II u y I' 11 fl 11 I II I II II I 11 I II I I I I I I I 11 I I I I I I 11 11 I I r 11 /I /I I/ 1 1 ti PROPOSED SAN MH. TC 851.00 (E) INV. 840.95 (W) INV. 840.85 OUTFALL STROME W/ AH SEE DETAIL (N) INV. 842.00 S) INV. 842.00 MANHOLE TYPE `F W/ NEENAH R- 1772 -C TC 850.50 (N) INV. 841.57 (5) INV. 841.57 (W) INV. 841.57 TYPE •f" W/ NEENAH R- 1772 -C 850.50 u) L Qy C C 0 a. 0 C 0 U) 0) C C IJ 0 0 u) 0 C 0 0 C 0 0.. 0 C 0 C 0 0 a) a) 0 0 0 0 0 -I- co X 0 U- 0) co 0 N u) N. 0) 0 9- 0