HomeMy WebLinkAbout04080060 116th Street Center, Site Construction Plans pg. 0946 fi 16 +00 15 +00 BENCHMARK RM 209 -1. CHISELED SQUARE CUT IN SOUTHERN DOWN STREAM HEADWALL OF CSX RAILROAD (NOW MONON TRAIL). CULVERT FOR CARMEL CREEK ELVE. 829.43 1. WYES AND LATERALS TO BE 6" PIPE UNLESS OTHERWISE SPECIFIED. 2. ALL WYE CONNECTIONS SHALL HAVE A MINIMUM OF FIVE FOOT LATERAL EXTENSION CONNECTED TO THE WYE. THE END OF THE LATERAL SHALL BE PLUGGED OR CAPPED. 3. LATERALS RUNNING TO THE OPPOSITE SIDE OF STREET SHALL EXTEND TO WITHIN 5 FEET OF THE BUILDING LINE. 1. ANY PIPE INSTALLED AT LESS THAN MINIMUM GRADE AS SPECIFIED BY TEN STATES STANDARDS WILL NOT BE ACCEPTED BY THE CLAY TOWNSHIP REGIONAL WASTE DISTRICT. 2. ALL SANITARY SEWER WITH LESS THAN 6.5 FEET OF COVER TO HAVE AT LEAST ONE INFILTRATION /EXFILTRATION TEST AFTER ALL UTILITIES HAVE BEEN INSTALLED. THIS DCAM REQUIREMENT WILL BE COMPLETED PRIOR TO ACCEPTANCE FOR PUBLIC MAINTENANCE UNLESS WAIVED BY DCAM. 3. S.E. EXCLUSIVE SANITARY SEWER EASEMENT D. U.E. DRAINAGE AND UTILITY EASEMENT D.S.& U.E. DRAINAGE, SANITARY SEWER AND UTILITY EASEMENT 4. MANHOLES PROPOSED TO BE INSTALLED IN UNPAVED AREAS SHALL BE CONSTRUCTED SUCH THAT THE TOP OF CASTING (T.C.) IS A MINIMUM OF THREE (3) INCHES ABOVE THE FINISHED GRADE TO PREVENT PONDING OF WATER OVER THE CASTING. POSITIVE DRAINAGE AWAY FROM THE MANHOLE SHALL BE PROVIDED. 5. THE LOWEST FINISHED FLOOR ELEVATION SERVED MUST BE ONE (1) FOOT ABOVE THE TOP OF CASTING (T.C.) OF EITHER THE UPSTREAM OR DOWNSTREAM MANHOLE PER SECTION 13.02.A.2 OF THE CLAY TOWNSHIP REGIONAL WASTE DISTRICT STANDARDS FOR THE DESIGN AND CONSTRUCTION OF SANITARY SEWERS, MAY 1989, NORTH 1" 50' HORIZ. 1" 5' VERT. C 'Bench wall must extend across the entire width of the manhole with a grouted flow transition at far wall to the top of bench wall." GENERAL NOTES: J LATERAL NOTES: 14 +00 t F /`COMPACTED GRANULAR f BACKFILL i f J REQUIRED REQU RED r 351 LF OF 8" PVC SDR -35 1.57% //j f/ /PROPOSED 8 9 WATERMAIN J 13+00 J/ i J t J f i f f m f i i ////i f 7„/ 840, 3 NISHED 1_0 3R EI..F`V. 651.50 STREET .00R l .50 FINISHED FLOOR ELEV, E.V. 853.50 S I D M1EC ISLAND (WEST STORMTT.CH UNDERGROUND ST0RAL#: 29 ROWS x 12 CNAL1DERS ((146901 BOT O&i x 01 4 UN f E 8113 5u^ REF T uniu Lam L au r_r117 :u L7.ZTyrI1;.LZ7 'PIPE I CLEAN OUT TC. 853.5 NV. ELEV. 547.00 EAST 116th STREET fJ STREE "B ssu 7 "i7 STGRMTEC ISLAND STORMLTECH UNDERGROUND STORAGE 19 ROWS x it CHAMBERS (91'x80') BO UNL 295 2 rr: 0 10 .7 i G (72 J) rs- UGT 12 +00 FIN SHED I-1 t` ''12 853., 0 TYPE I CLEAN OUT TC. 853.3 INV. ELEV. 847 i''TREE 8 7 i J f i 11 +00 j �J PROPOSED 21" RCP INV. ELEV. 843.59 b/ f i ALL BENCHWALLS MUST EXTEND TO CROWN OF HIGHEST INFLUENT PIPE. J I f /r/ J f •J „1/ f` J f /r J 325 LF OF 8" PVC SDR -35 0.45% 10 +00 J -t 0 f f f' O 10 co L.il J 40" ACMPTirar r j J 1/////////:/,, J r i 72 LF OF 8" PVC SDR- 35 0.45% 9 +00 O -1'0 a; co L1J J LLJ 6 t PR OR TO BACKFILLING SURVEYOR TO OBTAIN ACCURATE HORIZONTAL STUB LOCATION WITH I CONTRACTOR MUST COORDINATE WITH AN UPSTREAM AS -BUILT INVERT ELEVATION AND LOCATION. CONTRACTOR TO MARK END OF AINTED GREEN 2 "X4 `11 t F I f f f PROPOSED 15" RCP INV. ELEV. 844.44 //r" 1///////' /VJ/ PROPOSED 15" RCP/ /INV. ELEV. 842.41 PROPOSED 8" PVC SDR- 35'/, (E) INV. ELEV. 837.79 f fi 8 +00 7 +00 EXISTING SANITARY MANHOLE T.C. ELEV. 849.99 BENCHWALL ELEV. 835.99 INV. 8' PVC E. 835.56 INV. 8 PVC W. 835.51 354 LF OF 8" PVC SDR -35 0.45% TYPE I CLEAN OUT TC. 851.0 i NY. ELEV. 548.00 CONTRACTOR MUST FIELD VERIFY ELEVATION OF EXISTING WATER MAIN AND FIBER OPTIC PRIOR TO CONSTRUCTION. r l /PROPOSED 12" !J F WAT RMAIN J 6 BY OTHERS /J 6 +00 �-f CONTRACTOR COR E EX I /r L� STING MAN HE AND INST A LL PRESS WEDGE II BOOT. CONTRACTOR INS J BE C N t-i W F LL EtSTiNG r A i TH r E XT N E x lv1ANr iC;'LI= WNrCFi SI -iALL T O TH R CROWN E N 0 E C 0 F THE, H INFLUENT J I D 0 HIG EST ,CONTRACTOR MUST CONTACT 'CARMEL AFTER COMPLETION EON FIRST JOI TO OBTAIN AS -BUILT ,INVERT ELEVATION/ 'OF THE CORE. AFTER COMPLETION OF WORK, C 'MUST VACUUM, TEST MANHOLE. f' /;'`'�,/r,,/ FINISHED FLOOR ELEV. 851.50 UGE 27/ 7 COMPACTEt GRANULAR r BACKFILL /REQUIRED r f j I fJflf(/ F f 5 +00 870 850 840 860 1-i EXISTING 8" SANITARY MAIN (E) INV. ELEV. 835.56 \-EXISTING 8" SANITARY MAIN (W) INV. ELEV. 835.51 Sanitary c ut sewer shall be open for -J installation t o and Contractor must keep at least one travel lane oven at all times I- Lei 1z Q 0- z z “D REVISIONS DRAWING: 2308501 DATE: 12/16/05 PROJ. NO.: 2308 DRAWN BY: MG SHEET NO.: C501 TUBE FILE