HomeMy WebLinkAbout04080060 116th Street Center, Site Construction Plans pg. 15PART 3 CHAMBER PIPE C17F A B c o 24" .w .mm n I a t mm :t In .:mm mm SC740EPEO6B SC 740 6 in (150 mm) 10.90 in (277 mm) 3.85 in (98 mm) N/A 0.50 in (13 mm) SC740EPE12T SC 740 12 in (300 mm) 14.70 in (373 mm) 7.70 in (196 mm) 12.50 in (318 mm) NIA SC740EPE12B SC 740 12 in (300 mm) 14.70 in (373 mm) 7.70 in (198 mm) WA 120 in (30 mm) SC740EPE15T SC 740 15 in (375 mm) 18.40 in (467 mm)10.36 in (263 mm) 9.00 in (229 mm) N/A SC74OEPE15B SC 740 15 in (375 mm) 18.40 in (467 mm)10.36 in (263 (rim) WA 130 in (33 mm) SC740EPE18T SC 740 18 in (460 mm) 19.70 in (500 mm) 10.72 in (272 mm) 5.00 in (127 mm) N/A SC740EPE18/3 SC 740 18 In (480 mm) 19.70 In (500 mmy10.72 in (272 mm) N/A 1.80 In (41 mm) SC740EPE24B SC 740 24 in (600 mm) 18.50 in (470 mm) 9.45 in (240 mm) N/A 0.10 in (3 mm) MATERIAL LOCATION DESCRIPTION STUB SIZE 48" 42 36" 30' 24" 18' 15" 12" 10" 8" 24" AVAIL AVAIL AVAIL AVAIL AVAIL AND PREPARATION REQUIREMENTS. 18" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 15" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 12" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL WASHED ANGULAR STONE WITH THE 10" AVAIL AVAIL AVAIL AVAIL AVAIL 8' AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL 6" AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL AVAIL MATERIAL LOCATION DESCRIPTION AASHTO M43 DESIGNATION AASHTO M145 DESIGNATION COMPACTION/DENSITY REQUIREMENT FILL MATERIAL FROM 18" ANY SOIUROCK MATERIALS, NATIVE N/A N/A PREPARE PER ENGINEERS PLANS. PAVED TO GRADE ABOVE CHAMBERS SOILS OR PER ENGINEER'S PLANS. INSTALLATIONS MAY HAVE STRINGENT MATERIAL CHECK PLANS FOR PAVEMENT AND PREPARATION REQUIREMENTS. SUBGRADE REQUIREMENTS. OC FILL MATERIAL FOR 6" TO 18" GRANULAR WELL GRADED 3, 357, 4, 467, A -1 COMPACT IN 6" LIFTS TO A MINIMUM 95% ELEVATION ABOVE CHAMBERS SOIUAGGREGATE MIXTURES, 5, 56, 57, 6, A -2 STANDARD PROCTOR DENSITY. ROLLER GROSS (24" FOR UNPAVED INSTALLATIONS) <35% FINES. 67, 68, 7, 78, 8, 89, 9, 10 A -3 VEHICLE WEIGHT NOT TO EXCEED 12,000 LB p. DYNAMIC FORCE NOT TO EXCEED 20,000 LBS. EMBEDMENT STONE SURROUNDING WASHED ANGULAR STONE WITH THE 3, 357, 4, 467, 5, N/A NO COMPACTION REQUIRED AND TO A 6" ELEVATION ABOVE MAJORITY OF PARTICLES BETWEEN 56, 57 CHAMBERS 3 2 INCH FOUNDATION STONE BELOW WASHED ANGULAR STONE WITH THE 3, 357, 4, 467, N/A PLATE COMPACT OR ROLL TO ACHIEVE A CHAMBERS MAJORITY OF PARTICLES BETWEEN 5, 56, 57 95% STANDARD PROCTOR DENSITY 2 INCH CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND SAFETY FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD. PLEASE NOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE WASHED CRUSHED ANGULAR. FOR EXAMPLE, THE STONE MUST BE SPECIFIED AS WASHED, CRUSHED, ANGULAR NO. 4 STONE. CATCH BASIN OR MANHOLE SUMP ER DESIGN ADS 601 GEOTEXTILE OR EQUAL FOR UNPAVED INSTALLATION WHERE K: RUTTING FROM VEHICLES MAY OCCUR �R INCREASE COVER TO 24 INCHES 2 INCH WASHED, CRUSHED, ANGULAR STONE DESIGN ENGINEER IS RESPONSIBLE FOR ENSURING SUITABILITY OF SUBGRADE SOILS* FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 `SEE STORMTECH'S DESIGN MANUAL STORMTECH ACCEPTABLE FILL MATERIALS MANHOLE WITH OVERFLOW WEIR SC -740 TYPICAL CROSS SECTION ECCENTRIC HEADER SC -740 CHAMBER H11=1 1=1 I�i��1 1I1 -1l1 -111 -111 ►II�II II�11 l�1II -IiNI! STORMTECH PREFABRICATED END CAPS NOTE: INSPECTION PORT REQUIRED CENTER OF THE EACH ISOLATOR ROW (TOTAL 2 REQUIRED) ACCEPTABLE FILL MATERIALS STORMTECH SC -740 CHAMBER SYSTEMS 111!11 �iililHhIIIIIIIIIJ �I'�illiiiiiiiilllii• {1 y STRUCTURE DESIGNATION 111111111111111111i EAST ISLAND: IR2 1 I WEST ISLAND: IR1 1 iililliuill1ili�� IIIINIIIIIIII SC -740 END CAP GRANULAR WELL GRADED SOIL/AGGREGATE MIXTURES, c35% FINES. COMPACT IN 6 IN LIFTS TO 95% PROCTOR DENSITY. SEE THE TABLE OF ACCEPTABLE FILL MATERIALS IN STORMTECH'S DESIGN MANUAL, INSTALLATION MANUAL, OR WWW.STORMTECH.COM. Ij= 6" MIN. iiii 1 n 4 'tit! r4� A 1 I Door 0111111_ 41∎ PAVEMENT "NOTE: MIN. FOUNDATION STONE DEPTH: 12" MIN. STONE COVER ON CHAMBERS: 12" 5' W X 5' L WIDE STRIP REQUIRED EACH DIRECT INLET CHAMBER (WOVEN GEOTEXTILE THAT MEETS ADS 9530TK GEOTEXTILE OR EQUAL, BETWEEN FOUNDATION STONE AND CHAMBERS) /II I/, 1 1// 1 11 WOVEN GEOTEXTILE THAT MEETS ADS 9530TK GEOTEXTILE OR EQUAL, BETWEEN FOUNDATION STONE AND CHAMBERS SC- 740 -5' -6' WIDE STRIP SC- 310-4' WIDE STRIP �If 11=1II 51" STORMTECH CHAMBERS 18" 96" 12 "MIN. MIN. MAX. 30" 12" 12" MIN. TYP. STORMTECH ISOLATOR ROW FOR STORMTECH INFORMATION CALL 1- 888 892 -2694 STORMTECH ISOLATOR ROW MANIFOLD DETAIL INSPECTION PORT BY DESIGN ENGINEER 111=111=11 I I I� i j i iIf NI, III STORMTECH ISOLATOR ROW DETAIL COVER ENTIRE ROW WITH ADS 601 GEOTEXTILE OR EQUAL SC- 740-8' WIDE STRIP SC -310 -5' WIDE STRIP STORMTECH ENDCAP 1 1' FOR STORMTECH INFORMATION CALL 1- 888 -892 -2694 BED PERIMETER NUMBER AND SIZE OF UNDERDRAINS PER ENGINEER DESIGN A I FOR STORMTECH INFORMATION CALL 1- 888 -892 -2694 TO OUTLET CONTROL STRUCTURE SC -740 CHAMBER AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE A STORMTECH SINGLE TEE MANUFACTURED BY ADS J J PERFORATED UNDERDRAIN PIPE STORMTECH CHAMBER FOUNDATION STON BENEATH CHAMBE B ADS 601 GEOTEXTILE OR EQUAL 4x PIPE 0 MIN STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) A-- STORMTECH TRIPLE ECCENTRIC MANIFOLD MANUFACTURED BY ADS AVAIL STANDARD HEADERS AVAILABLE FOR INFORMATION CALL 1 -888- 892 -2694 '1- ...A, SECTION B_B V A A STORMTECH CHAMBER OUNDATION STONE ENEATH CHAMBER ADS 601 GEOTEXTILE OR EQUAL 4x PIPE 0 MIN STONE BEDDING UNDER DRAINAGE PIPE (PER DESIGN) SECTION A A PERFORATED UNDERDRAIN PIPE STORMTECH UNDERDRAIN DETAIL NOTES: 1. ALL DESIGN SPECIFICATIONS FOR STORMTECH CHAMBERS SHALL BE IN ACCORDANCE WITH THE STORMTECH DESIGN MANUAL. 2. THE INSTALLATION OF STORMTECH CHAMBERS SHALL BE IN ACCORDANCE WITH THE LATEST STORMTECH INSTALLATION INSTRUCTIONS. 3. THE CONTRACTOR IS ADVISED TO REVIEW AND UNDERSTAND THE INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM INSTALLATION. CALL 1- 888 892 -2694 OR VISIT WWW.STORMTECH.COM TO RECEIVE A COPY OF THE LATEST STORMTECH INSTALLATION INSTRUCTIONS. 4. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND SAFETY FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD. FLOOR BOX FRAME AND LID W /S.S. CAP SCREW LID CLOSURE INSPECTION PORT WITH SCREW -IN CAP CLASS "C" CONCRETE AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE IIIIII1III1'II11III1II11III1I1IIIIII11II1II STORMTECH DOUBLE MANIFOLD MANUFACTURED BY ADS INSPECTION PORT TO BE ATTACHED THROUGH KNOCK -OUT LOCATED AT CENTER OF CHAMBER A A ADS MANIFOLD DETAILS ISOLATOR ROW IN 24" HDPE PIPE 6' MANHOLE 10' INLET PIPE INVERT INVERT FOR STORMTECH INFORMATION CALL 1-888- 892 -2694 STORMTECH INSPECTION PORT DETAIL ‘101 SECTION VIEW A-A MANIFOLDS ARE DESIGNED TO BE COUPLED TO STORMTECH PREFABRICATED END CAPS. WHEN USING STANDARD END CAPS, CORRUGATE DPIPE UP TO 18 INCHES CAN BE INSERTED DIRECTLY INTO THE END CAP. FOR 24" INLET PIPES, A CORRUGATED TO SMOOTH PIPE ADAPTER IS REQUIRED. STORMTECH CHAMBERS 10" INLET PIPE INVERT ELEVATIONS WEST ISLAND ELEV. 843.50 EAST ISLAND ELEV. 842.95 36" HEADER INLET PIPE INVERT ELEVATIONS WEST ISLAND ELEV. 841.33 EAST ISLAND ELEV. 840.78 12" HEADER OUTLET PIPE INVERT ELEVATIONS WEST ISLAND ELEV. 843.50 EAST ISLAND ELEV. 842.95 STORMTECH CHAMBERS SECTION B_B OVERFLOW WEIR INLET OUTLET: MINIMUM NUMBER OF CHAMBERS ROWS REQUIRING DIRECT INLET OUTLET FROM 10" PIPE: WEST ISLAND: 10 CHAMBERS EAST ISLAND: 8 CHAMBERS *DIRECT INLET OUTLET TO/FROM FIRST AND LAST CHAMBERS ROW REQUIRED B MAXIMUM FINISHED GRADE ELEV. 853.45 MINIMUM FINISHED GRADE ELEV. 847.95 IN BOTTOM OF CHAMBERS EST ISLAND ELEV. 843.50 EAST ISLAND ELEV. 842.95 BOTTOM OF CHAMBER ELEV. BOTTOM OF FOUNDATION STONE ELEV. BOTTOM OF FOUNDATION WEST ISLAND ELEV. 842.50 EAST ISLAND ELEV. 841.95 STORMTECH ELEVATIONS STORMTECH GENERAL NOTES 1. STORMTECH LLC "STORMTECH REQUIRES INSTALLING CONTRACTORS TO USE AND UNDERSTAND STORMTECH'S LATEST INSTALLATION INSTRUCTIONS PRIOR TO BEGINNING SYSTEM INSTALLATION. 2. OUR TECHNICAL SERVICES DEPARTMENT OFFERS INSTALLATION CONSULTATIONS TO INSTALLING CONTRACTORS. CONTACT OUR TECHNICAL SERVICES REPRESENTATIVE AT LEAST 30 DAYS PRIOR TO SYSTEM INSTALLATION TO ARRANGE A PRE INSTALLATION CONSULTATION. OUR REPRESENTATIVES CAN THEN ANSWER QUESTIONS OR ADDRESS COMMENTS ON THE STORMTECH CHAMBER SYSTEM AND INFORM THE INSTALLING CONTRACTOR OF THE MINIMUM INSTALLATION REQUIREMENTS BEFORE BEGINNING THE SYS I EM'S CONSTRUCTION. CALL 1- 888492 -2694 TO SPEAK TO A TECHNICAL SERVICE REPRESENTATIVE OR VISIT WWW.STORMTECH.COM TO RECEIVE A COPY OF OUR INSTALLATION INSTRUCTIONS. 3. STORMTECH'S REQUIREMENTS FOR SYSTEMS WITH PAVEMENT DESIGN (ASPHALT, CONCRETE PAVERS, ETC.): MINIMUM COVER IS 18 INCHES NOT INCLUDING PAVEMENT; MAXIMUM COVER IS 96 INCHES INCLUDING PAVEMENT. FOR INSTALLATIONS THAT DO NOT INCLUDE PAVEMENT, WHERE RUTTING FROM VEHICLES MAY OCCUR, MINIMUM REQUIRED COVER IS 24 INCHES, MAXIMUM COVER IS 96 INCHES. 4. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE DESIGN ENGINEER. 5. AASHTO M288 CLASS 2 NON -WOVEN GEOTEXTILE (FILTER FABRIC) MUST BE USED AS INDICATED IN THE PROJECT PLANS. STONE PLACEMENT BETWEEN CHAMBERS ROWS AND AROUND PERIMETER MUST FOLLOW INSTRUCTIONS AS INDICATED IN THE MOST CURRENT VERSION OF STORMTECH'S INSTALLATION INSTRUCTIONS. 7. BACKFILLING OVER THE CHAMBERS MUST FOLLOW REQUIREMENTS AS INDICATED IN THE MOST CURRENT VERSION OF STORMTECH'S INSTALLATION INSTRUCTIONS, 8. THE CONTRACTOR MUST REFER TO STORMTECH'S INSTALLATION INSTRUCTIONS FOR A TABLE OF ACCEPTABLE VEHICLE LOADS AT VARIOUS DEPTHS OF COVER. THIS INFORMATION IS ALSO AVAILABLE AT STORMTECH'S WEBSITE: WWW.STORMTECH.COM. THE CONTRACTOR IS RESPONSIBLE FOR PREVENTING VEHICLES THAT EXCEED STORMTECH'S REQUIREMENTS FROM TRAVELING ACROSS OR PARKING OVER THE STORMWATER SYSTEM. TEMPORARY FENCING, WARNING TAPE AND APPROPRIATELY LOCATED SIGNS ARE COMMONLY USED TO PREVENT UNAUTHORIZED VEHICLES FROM ENTERING SENSITIVE CONSTRUCTION AREAS. 9. THE CONTRACTOR MUST APPLY EROSION AND SEDIMENT CONTROL MEASURES TO PROTECT THE STORMWATER SYSTEM DURING ALL PHASES OF SITE CONSTRUCTION PER LOCAL CODES AND DESIGN ENGINEER'S SPECIFICATIONS. 10. STORMTECH PRODUCT WARRANTY IS LIMITED. SEE CURRENT PRODUCT WARRANTY FOR DETAILS. TO ACQUIRE A COPY CALL STORMTECH AT 1-888- 892 -2694 OR VISIT WWW.STORMTECH.COM. SECTION A A 4" UNDERDRAIN PIPE ELEV. 842.50 (WEST ISLAND) ELEV. 841.95 (EAST ISLAND) FOR STORMTECH INFORMATION CALL 1- 888 -892 -2694 TOP OF WEIR ELEVATIONS STR. IR1 ELEV. 844.50 STR. IR2 ELEV. 844.00 WEIR PLATE ELEV. 24" PIPE ELEV. 36" MANIFOLD PIPE ISOLATOR ROW STORMTECH STUB PREFABRICATED END CAP 24" PIPE INVERT ELEVATIONS WEST ISLAND ELEV. 843.50 EAST ISLAND ELEV. 842.95 90.7" ACTUAL LENGTH NOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) CHAMBER STORAGE MINIMUM INSTALLED STORAGE WEIGHT STUBS AT TOP OF END CAP FOR PARTS NUMBERS ENDING WITH T NOM ALL OB,EUSIC SARENOMINAL ALL STUBS. EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1. 888.892- 2894. STORMTECH PRODUCT SPECIFICATIONS 1.0 GENERAL 1.1 STORMTECH CHAMBERS ARE DESIGNED TO CONTROL STORMWATER RUNOFF. AS A SUBSURFACE RETENTION SYSTEM, STORMTECH CHAMBERS RETAIN AND ALLOW EFFECTIVE INFILTRATION OF WATER INTO THE SOIL. AS A SUBSURFACE DETENTION SYSTEM, STORMTECH CHAMBERS DETAIN AND ALLOW FOR THE METERED FLOW OF WATER TO AN OUTFALL. 2.0 CHAMBER PARAMETERS 2.1 THE CHAMBER SHALL BE INJECTION MOLDED OF POLYPROPYLENE RESIN TO BE INHERENTLY RESISTANT TO ENVIRONMENTAL STRESS CRACKING (ESCR), AND TO MAINTAIN ADEQUATE STIFFNESS THROUGH HIGHER TEMPERATURES EXPERIENCED DURING INSTALLATION AND SERVICE 2.2 THE NOMINAL CHAMBER DIMENSIONS OF THE STORMTECH SC-740 SHALL BE 30.0 INCHES TALL, 51.0 INCHES WIDE AND 90.7 INCHES LONG. THE NOMINAL CHAMBER DIMENSIONS OF THE STORMTECH SC-310 SHALL BE 16.0 INCHES TALL, 34.0 INCHES WIDE AND 90.7 INCHES LONG. THE INSTALLED LENGTH OF A JOINED CHAMBER SHALL BE 85.4 INCHES. 2.3 THE CHAMBER SHALL HAVE A CONTINUOUSLY CURVED SECTION PROFILE. 2.4 THE CHAMBER SHALL BE OPEN BOTTOMED. 2.5 THE CHAMBER SHALL INCORPORATE AN OVERLAPPING CORRUGATION JOINT SYSTEM TO ALLOW CHAMBER ROWS OF ALMOST ANY LENGTH TO BE CREATED. THE OVERLAPPING CORRUGATION JOINT SYSTEM SHALL BE EFFECTIVE WHILE ALLOWING A CHAMBER TO BE TRIMMED TO SHORTEN ITS OVERALL LENGTH. 2.6 THE NOMINAL STORAGE VOLUME OF A JOINED STORMTECH SC-740 CHAMBER SHALL BE 74.9 CUBIC FEET PER CHAMBER WHEN INSTALLED PER STORMTECH'S TYPICAL DETAILS (INCLUDES THE VOLUME OF CRUSHED ANGULAR STONE WITH AN ASSUMED 40% POROSITY). THIS EQUATES TO 22 CUBIC FEET OF STORAGE/SQUARE FOOT OF BED. THE NOMINAL STORAGE VOLUME OF AN INSTALLED STORMTECH SC -310 CHAMBER SHALL BE 31.0 CUBIC FEET PER CHAMBER WHEN INSTALLED PER STORMTECH'S TYPICAL DETAILS (INCLUDES THE VOLUME OF CRUSHED ANGULAR STONE WITH AN ASSUMED 40% POROSITY). THIS EQUATES TO 1.3 CUBIC FEET OF STORAGE/SQUARE FOOT OF BED. 2.7 THE CHAMBER SHALL HAVE FORTY -EIGHT ORIFICES PENETRATING THE SIDEWALLS TO ALLOW FOR LATERAL CONVEYANCE OF WATER. STORMTECH SC -740 CHAMBER LAYOUT ACCEPTS 4" SCH 40 PIPE FOR CLEANOUT OR INSPECTION PORT FOR THE SC740EPE24B THE 24' STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75'. BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N -12 STUB SO THAT THE FITTING SETS LEVEL TECHNICAL DETAILS 51.0" x 30.0 x 85.4' 45.9 CUBIC FEET 74.9 CUBIC FEET 75 LBS. STUBS AT BOTTOM OF END CAP FOR PARTS NUMBERS ENDING WITH "13" 2.10 THE CHAMBER SHALL HAVE 14 CORRUGATIONS. 2.8 THE CHAMBER SHALL HAVE TWO ORIFICES NEAR ITS TOP TO ALLOW FOR EQUALIZATION OF AIR PRESSURE BETWEEN ITS INTERIOR AND EXTERIOR. 2.9 THE CHAMBER SHALL HAVE BOTH OF ITS ENDS OPEN TO ALLOW FOR UNIMPEDED HYDRAULIC FLOWS AND VISUAL INSPECTIONS DOWN A ROWS ENTIRE LENGTH. 2.11 THE CHAMBER SHALL HAVE A CIRCULAR, INDENTED, FLAT SURFACE ON THE TOP OF THE CHAMBER FOR AN OPTIONAL 4 -INCH INSPECTION PORT OR CLEAN -OUT. 2.12 THE CHAMBER SHALL BE ANALYZED AND DESIGNED USING AASHTO METHODS FOR THERMOPLASTIC CULVERTS CONTAINED IN THE LRFD BRIDGE DESIGN SPECIFICATIONS, 2ND EDITION, INCLUDING INTERIM SPECIFICATIONS THROUGH 2001. DESIGN LIVE LOAD SHALL BE THE AASHTO HS20 TRUCK. DESIGN SHALL CONSIDER EARTH AND LIVE LOADS AS APPROPRIATE FOR THE MINIMUM TO MAXIMUM SPECIFIED DEPTH OF FILL. 2.13 THE CHAMBER SHALL BE MANUFACTURED IN AN ISO 9001:2000 CERTIFIED FACILITY. 3.0 END CAP PARAMETERS 3.1 THE END CAP SHALL BE INJECTION MOLDED OF POLYPROPYLENE RESIN TO BE INHERENTLY RESISTANT TO ENVIRONMENTAL STRESS CRACKING, AND TO MAINTAIN ADEQUATE STIFFNESS THROUGH HIGHER TEMPERATURES EXPERIENCED DURING INSTALLATION AND SERVICE. 3.2 THE END CAP SHALL BE DESIGNED TO FIT INTO ANY CORRUGATION OF A CHAMBER, WHICH ALLOWS: CAPPING A CHAMBER THAT HAS ITS LENGTH TRIMMED; SEGMENTING ROWS INTO STORAGE BASINS OF VARIOUS LENGTHS. 3.3 THE END CAP SHALL HAVE SAW GUIDES TO ALLOW EASY CUTTING FOR VARIOUS DIAMETERS OF PIPE THAT MAY BE USED TO INLET THE SYSTEM. 3.4 THE END CAP SHALL HAVE EXCESS STRUCTURAL ADEQUACIES TO ALLOW CUTTING AN ORIFICE OF ANY SIZE AT ANY INVERT ELEVATION. 3.5 THE PRIMARY FACE OF AN END CAP SHALL BE CURVED OUTWARD TO RESIST HORIZONTAL LOADS GENERATED NEAR THE EDGES OF BEDS. 3.6 THE END CAP SHALL BE MANUFACTURED IN AN ISO 9001:2000 CERTIFIED FACILITY. CHAMBERS SHALL MEET THE DESIGN REQUIREMENTS AND SAFETY FACTORS SPECIFIED IN SECTION 12.12 OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. LOADS SHALL BE CALCULATED IN ACCORDANCE WITH SECTION 3 AND SHALL INCLUDE H2O DESIGN TRUCK, IMPACT FACTOR, MULTIPLE PRESENCE, AND LANE LOAD. SAVED AS DRAWN BY SCALE DATE w z t w O 0 DRAWING TITLE PROJECT NO. REVISIONS SITE PLAN STORMTECH SC-740 CHAMBER DETAIL SHEET DATE DRAWING NO 0.4 (n 1 0) C 0 0. C O J rn 00 N N U) i O 0) Q O 0 C C .O C 0 LL! C 5 0 0 CD N X lL rn (O 0 0 N IC) M 1- 0 Ct Q Q_ Z f J� REVISIONS DRAWING: 2308C802A DATE: 12/16/05 PROJ. NO.: 2308C DRAWN BY: KJK SHEET NO.: C802A TUBE FILE