HomeMy WebLinkAbout04090012 VOWC Sec. 3004 BLK D - Brenwick Realty, Construction Plans pg. 05DIMENSIONS (INCHES) a BRENWICK DEVELOPMENT CO. CARMEL, INDIANA PROJECT NO.: 1238.035 DRAWN BY: DCC CHECKED BY: SHEET TITLE: GENERAL DETAILS SPECIFICATIONS DRAWING FILES: N: \1238 \035 \DWGS \C801.DWG SHEET NO.: C80 .e' 36 21 18 A] 1, D 25 21 48 28 24 48 31 27 60 34 DIMENSIONS (INCHES) DATE: 9/07/04 PROJECT NO.: 1238.035 DRAWN BY: DCC CHECKED BY: SHEET TITLE: GENERAL DETAILS SPECIFICATIONS DRAWING FILES: N: \1238 \035 \DWGS \C801.DWG SHEET NO.: C80 .e' 36 21 DIMENSIONS (INCHES) A (MAX) B (I.D.) C (MIN) 12 36 18 15 36 21 18 48 25 21 48 28 24 48 31 27 60 34 30 60 38 33 60 41 36 60 44 42 60 50 PIPE SIZE 12 -15" 18" OVER BEDDING BELOW 0.D. /4 O.D. /4 THE PIPE BARREL MIN =4" MAX =8" c L c c 5' -0" BETWEEN TRANSVERSE JOINTS I/L r wrummcv JOINT FILLER NIFI „0 -,1 TRANSVERSE JOINT TRANSVERSE JOINT 1/2" PREFORMED 7 iii i iQ TYPICAL SANITARY SEWER SPECIFICATIONS TO BE USED FOR PRIVATE SEWER DEVELOPMENT WITHIN CLAY TOVVNSHIP REGIONAL WASTE DISTRICT REVISED MAY, 2002 1. Standard specifications of the Clay Township Regional Waste District (District) and Indiana Department of Transportation shall apply for all work and materials. Pipe shall be d in accordance with Section 715 of the latest edition of the Indiana Department of Transportation Standard 2. Sarntary sewer pipe shall be PVC in accordance with ASTM D -3034 pipe shall have a grooved bell and vsket The pipe shall be made of PVC plastic having a cell classification of 12454B. 3. PVC sewer fittings shall conform to the requirements of ASTM D-3034-89 specification. Fittings I sizes through 8" shall be molded in one piece with elastomeric joints and minimum socket depths as specified in sections 6.2 and 7.3.2. Fittings 10" and larger shall be molded or fabric:oted in accordance with section 7.11 with manufacturers standard pipe bells and gaskets. Wall thickness of fittings shall be SDR 26 as defined in section 7.4.1 of specifications. ets for elastomeric joints shall be molded with a minimum cross-sectional area of 0.20 square inches and specification. conform to ASTM F-477 4, All sanitary manholes shall be "precast concrete" manholes in acc,ordonce with ASTM C-478 and Section 720. 0 -rings shall conform to C-4-43 Kent Seal or equivalent II also be applied to all joints and between riser rings and castin Manhole step spacing shall be no more than 16- inches. Manholes shall be air tested for leakage in accordance with ASTM C1244-93, Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test. A Installation and operation of vacuum equipment and indicating devices rnust be in accordance with manufacturer's recommendations and performance specifications which have been provided by the manufacturer and accepted by the Engineer. The vacuum equipment must be capable of testing the entire manhole, including the casting and riser rings. B. With the vacuum tester set in place: 1, Connect the vacuum pump to the outlet port with the valve open. 2. Draw a vacuum of ten (10) inches of Hg. and close the valve. c. Accepted standards for leakage will be established from the elapsed time for a negative pressure change from ten (10) inches to nine (9) inches of mercury. The maximum allowable leakage rate for a four (4) foot diameter manhole must be in accordance with the following: Minimum Elapsed Time for a Manhole Depth Pressure Change of 1 Inch Hg 10 feet or less 60 seconds >10 feet but <15 feet 75 seconds >15 feet but <25 feet 90 seconds For manholes five (5) feet in diameter, add an additional fifteen (15) seconds and for manholes six (6) feet in diameter, add an additional thirty (30) seconds to the time requirements for four (4) foot diameter n For at manholes deeper than twenty -five (25) feet. Engineer will determine the applicable minimum elapsed time. D. If the manhole fails the test, necessary repairs must be made and the vacuum test and repairs must be repeated until the manhole passes the test. E. If manhole joint sealants are pulled out during the vacuum test, the manhole must be disassembled and the joint sealants replaced. F. Manholes will be subject to visual inspection with all visual leaks being repaired. 5. Butyl rubber coating shall be applied around each manhole joint from 6- inches above to 6- inches below each joint. The appropriate primer shall be applied prior to applying the rubber coating. Inside joints to be filled with precoat plug material. 6. The manhole chimney's including all riser rings shall be sealed using infi- Shield "Uniband" or approved equal. Prior to placement, the top 4- inches of the manhole cone and casting frame shall be cleaned and primed. The Uniband shall extend from 3- inches below the top of the cone section to 2- inches over the flange of the manhole casting frame. 7. The casting elevations are set by plan. However, the castings are to be adjusted in the field by the Engineer's representative, should a discrepancy occur between plan grade and existing grade. New manhole ring and cover shall be installed to establish grade. Maximum height of adjusting rings shot be 12- inches. 8. Backfill around all structures and all cuts under paved areas with granular material. Trenches opening within 5 -feet of paved roadways shall be backfilled with granular material in accordance with Section 211. Backfill under sidewalks shall be granular, unless the walks are constructed a minimum of 6 months after backfill has been in place. 9. The Contractor shall be responsible for verifying that all state highways, city, and county permits have been obtained by the developer prior to start of construction. 10. The Contractor shall be required to furnish the developer's Engineer with a set of prints, marked in red pencil, showing actual sewer location and invert, to include lateral location, depth and length. Such as built" prints must be received by the Engineer before the final contract payment can be authorized. The sanitary sewer laterals and stubs termination shall be indicated on the surface with a metal fence post set immediately above the said termination point. M. All sanitary sewer lines upon completion will be required to pass a low pressure air test. Said test shall be conducted according to ASTM 1417 -92, and shall be witnessed by an Engineer and a representative of the District. The testing shall be in accordance with Table 1. Add 0.5 psig for each foot of water above the sewer line being tested. 12. Deflection tests shall be performed on all flexible* pipe after the final bockfiil has been in place at least 30 days. No pipe shall exceed a vertical deflection of 5% deflection test results. *The following are considered !ion flexible pipes: concrete pipe, ductile iron pipe, and cast iron pipe). The deflection test shall be performed with a nine -point mandrel. Proving rings shall be available. 13. All mandrel testing shall be observed by a professional engineer representative for certification and a representative of the District. 14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of withstanding a low pressure air test without leakage. 15. Bedding for flexible pipe shall be No. 8 crushed stone from 6- inches below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches below the pipe to the spring line of the pipe and from this point to 12- inches above shall be fill sand or equivalent. Manholes shall be placed on no Less than 6- inches of No. 8 crushed stone bedding. 16. Water and sewer line crossings and separations shall be in accordance with 3271AC 3 -6 -9. 17. Trench shall be opened sufficiently ahead of pipe laying to reveal obstruction, and shall be properly protected and /or barricaded when left unattended. 18. No water shall be permitted to flow into the sanitary sewer system during construction. Contractor shall utilize a pump to keep the water level below the pipe. Pump discharge shall be directed to a storm outlet in accordance with state and federal laws and regulations (327 -IAC 3- 6 -20). Any pipe entering existing sewers shall be plugged with screw type mechanical, braced plug until such time as all tests on the sewers have been completed and the lines have passed all punch lists. 19. At sewer laterals installed by the mainline Contractor shall be bedded the same as the main line sewer. 20. Forty -eight (48) hours notice shall be given to the District prior to the start of sewer construction. Also, 48 hours notice shall be given prior to doing any testing done on the sewer. 21. Manhole castings shall be stomped SANITARY SEWER, Neenah Casting R 1642A or equal and be self sealing type. The casting flange shall be 34 inches and the clear opening shall be 24 inches. Waterproof castings shall be Neenah R- 1916 -F1 and stamped SANITARY SEWER. 22. the minimum slope for sewer acceptance by the Clay Township Regional Waste District are: Size of Pipe Minimum Constructed Slope 8 -inch 10 -inch 12 -inch 15 -inch 18 -inch 0.40 0.28% 0.22% 0.15% 0.12% 23. The Contractor shall provide measurements of the slope of the sewer for each manhole section as construction progresses. Such measurements shall be certified by o Registered Land Surveyor or Engineer and be available on -site for observation by the District's Inspector. No more than three manhole sections can be constructed in advance of such measurements. 24. In the event the Contractor does not meet the minimum slopes, the sewer section and any other affected sewer sections shall be reconstructed to meet such minimum slopes. 25. Laterals are to be traced with a minimum size of 14 gouge wire from the wye to the terminus. The contractor for the building or home will extend the wire from this terminus to the building cleanout adjacent to the building. Ar Av Av ,r A r A Ar 4r Av TRANSVERSE EXPANSION JOINTS w J Iz X 0 I INLET DETAIL FOR PAVED AREA 0 0 0 0 0 0 0 EIOCIEI L3 CDIEOiII =LSO CIEICICICICIEZ3 CICIEDCII=CII=1 CI CI CI I=1 IC CI CI IE CI IE CI CI ===I= 6" "B" BORROW CURB JOINT DETAIL 30" R.C.P. (1) LINE 0.116 PIPE W.W.F. o PAVEMENT 100' NO. 3405-A NEENAH CASTING p Q a.. A 0 z w >i 0 c), .4 0 Q 0 o Q o U 0 0° o Q 0 0 0 Q o o 0 0 0 o 0 I o I o 4, V V r�w •1.11, 1w j�� PREPARED SUBGRADE PER INDOT No. 201 CONCRETE PAVEMENT SECTION cQo TRANSVERSE CONTRACTION JOINTS (20' MAX. SPACING) STRAIGHT CURB GUTTER NEENAH TYPE CASTING NO. R -3010 BOTTOM OF CURB STANDARD REINFORCED CONC. BASE SPECIAL STRAIGHT CURB INLET TOP OF CURB 0 0 0 0 0 0 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 00 o 6" CONCRETE PAVEMNT 6" GRANULAR FILL (MIN.) #53 COMPACTED STONE BASE FINISH GRADE INFl- SHIELD 'UNIBAND' OR APPROVED EQUAL SEAL b PER SPECIFICATIONS BUTYL RUBBER COATING AS PER SPECIFICATION PRECAST BASE 3" OF TOPSOIL EARTH BACKFILL EPDXY BONDING AGENT EXISTING PAVEMENT EXTRUDED CONCRETE CURB(Th 2' CONCRETE CHAIRBACK CURB (WITHOUT GUTTER) lillikTAPERED O" DIA PRECAST CONC. RINGS 4' -0 MIN. MANHOLE BASE FOR PRECAST 2 "R NEENAH R- 1642 -A OR JORDAN 104522 W /SELF SEAUNG LID (OR EQUAL) STAMPED "SANITARY SEWER" PRECAST CONCRETE SECTIONS A FILL WITH CONCRETE #4 0 12" EA. WAY 24" SECTION A -A SANITARY MANHOLE DETAIL NOTE MANHOLE CONFORMS TO ASTM C -478 JOINT CONFORMS TO ASTM C -443 CARMEL PAVEMENT PLAN 6 MIN. NO. 8 CRUSHED STONE REQUIRED UNDER MANHOLE BASE FOR LEVEUNG AND SUPPORT SEALED EXPANSION JOINT 1 1/2"R 1:10 PLACE 1/2" DIA EXTRUDABLE PREFORMED GASKET MATERIAL IN EACH KEYWAY (SEE DETAIL). PRECAST CONCRETE ADJUSTING RING OR FLANGE OF CASTING NOMINAL 1 /2 BUTYL RUBBER BASE T MATE ABLE PREFORMED GASKET MATERIAL (TYP) SEE DPW SPECS. 6'- A 4 -0" PLAN VIEW 6' -0" 1:10 MAX. 1:12 SLOPE X IF X< 48" THEN SLOPE OF FLARED SIDE SHALL NOT GRADE EXCEED 1:12 _7, III 41=111 CONCRETE CURB SECTION A-A X =WIDTH OF SIDEWALK WHEELCHAIR RAMP DETAIL Co) EX. 2' CHAIR BACK CURB PLAN VIEW GASKET DETAIL SECTION A -A ADJUSTING RING DETAIL (FIGURE 5 -4B) STD 2' CHAIR BACK CURB PAVEMENT SECTION 6" EXTRUDEABLE CURB MATCH EX. GRADES (D C801 REMOVE EXISTING CURB AND FORM NEW VALLEY GUTTER os'\ 8" MATCH EX. GRADES STD 2' CHAIR BACK CURB 8" BACKFILL 8" SECTION "A-A" 'V MODIFIED ENTRANCE COMPACTED SCORE 1/4" R SUBGRADE CONCRETE CURB AND WALK -3" OF TOPSOIL 6" re) (V VALLEY GUTTER AND SECTION (CHAIRBACK CURB) (EX. CHAIRBACK CURB) CONCRETE WALK 8 C801 SLOPE: 1/4" PER FOOT 24" 24" 3/4" STD 2' CHAIR BACK CURB PAVEMENT SECTION 6" EXTRUDEABLE CURB MATCH EX. GRADES 18" 'a COMPACTED SUBGRADE COMBINED CONCRETE CURB AND GUTTER (TYPE 11) MATCH EX. GRADES TRANSITION AREA STD 2' CHAIR BACK CURB APPROX. 90' 1" H.A.C. SURFACE #11 3" H.A.C. BINDER #9 2" #53 STONE 6" #2 STONE PREPARED SUBGRADE PER INDOT No. 201 TYPICAL PAVEMENT SECTION 000 O 0 0 ?J0 0 EX. 2' CHAIR BACK CURB 1/4" R NORMAL GRADE 1/4" PER FOOT MIN.-1/8" PER FOOT CONNECT TO EXISTING SERVICE PLUG FOR FUTURE CONNECTION. PLUG SHALL BE ABLE TO PASS AIR PRESSURE TEST REQUIRED FOR SEWER MAIN. USE 6" SEWER PIPE UNLESS OTHERWISE SPECIFIED FINISH GRADE r' PAVEMENT #8 CRUSHED STONE or #8 FRACTURED FACE AGGREGATE HAND TAMPED OR WALKED INTO 1/2 0.D. THE CONTRACTOR SHALL BE AWARE THAT IF THE TOP OF THE TRENCH IS WITHIN 5' OF THE PROPOSED FUTURE BACK OF CURB, THAT GRANULAR BACKFILL (NO. 53 AGGREGATE) SHALL BE PLACED IN THE EXCAVATION AND COMPACTED TO 95% MODIFIED PROCTOR AT 6" MAX. LIFTS. WIDTH VARIES BASED ON THE TYPE OF PIPE MATERIAL Sc DEPTH OF COVER. CONSULT THE PROJECT ENGINEER IF THE 6" CLEARANCE ON EACH SIDE OF THE PIPE IS NOT SUFFICIENT. THE EXCAVATION OF THE TRENCH SIDE SLOPES SHALL BE IN ACCORDANCE WITH I.0.S.H.A. REGULATIONS. IN THE EVENT THAT A SOFT AREA IS ENCOUNTERED OR THE BOTTOM OF THE TRENCH IS OVER DUG, THE TRENCH BOTTOM WILL BE REFILLED WITH NO. 8 COMPACTED AGGREGATE BEFORE THE PIPE IS LAID IN PLACE. THIS TRENCH DETAIL IS TO BE USED FOR ALL TYPES OF SANITARY SEWER PIPE MATERIAL INCLUDING P.V.C., (SDR -35) AND P.V.C. TRUSS PIPE. m CC FINISH GRADE COMPACTED GRANULAR BACKFILL TO BE USED UNDER ALL PAVED AREAS. MIN WIDTH 1.25 (0.D.) +12' FLEXIBLE (PVC or HDPE) PIPE BEDDING 4" MIN. PIPE TRENCH DETAIL 30' MIN 45' MAX. CLEANOUT PLUG SANITARY SEWER LATERAL 6" PIPE LONG RADIUS TYPICAL CLEANOUT DETAIL 50' -0" BETWEEN EXPANSION JOINTS (MAX.) CONCRETE SIDEWALK NOT TO SCALE SIDEWALK DETAIL #8 CRUSHED STONE or #8 FRACTURED FACE AGGREGATE HAND TAMPED OR WALKED INTO 1/2 0.D. +12" ABOVE TOP OF PIPE (BELOW BARREL) #8 CRUSHED STONE or #8 FRACTURED FACE AGGREGATE BELL HOLE EXCAVATED ISOMETRIC PLAN LONG RADIUS SECTION A-A DIAMETER AS SPECIFIED f ON PLAN OR SCHEDULE PLAN VIEW CONNECTION TO MAIN SEWER SPRING LINE OF PIPE 3 SIDE SLOPES) 1:2 OVER 16' 1:3 TO 16' 1:6 TO 12' 1:12 TO 8' CONNECT TO EXISTING SERVICE OR PLUG FOR FUTURE SERVICE. PLUG SHALL BE ABLE TO PASS AIR PRESSURE TEST REQUIRED FOR SEWER MAIN. FIBER REINFORCED CONC. (3000 PSI) Lil J C-3 IC 0 fal La.l (1) v") 5 w w o z o 0 ;m CV a\ N u I w n I I! I u// i /i, pON No.IS 0000:151/5:4 STATE '\�N B :t46,4046N L DATE: THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. COPYRIGHTED BY THE SCHNEIDER CORP. (2004) Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering