HomeMy WebLinkAbout03110012 VOWC Sec. 10003, Construction Plans pg. 13DATE: 10/31/03 a 1 CHECKED BY: SHEET TITLE: SANITARY SEWER PLAN PROFILE DRAWING FILES: N: \1238 \1003 \DWGS \C401- 402.DWG XREF: 1003— BS.DWG XREF: 1004— ABS.DWG XREF: 1002 BS.DWG XREF: SANITARY.DWG SHEET NO.: C40 I DATE: 10/31/03 PROJECT NO.: 1238.1003 DRAWN BY: DCC CHECKED BY: SHEET TITLE: SANITARY SEWER PLAN PROFILE DRAWING FILES: N: \1238 \1003 \DWGS \C401- 402.DWG XREF: 1003— BS.DWG XREF: 1004— ABS.DWG XREF: 1002 BS.DWG XREF: SANITARY.DWG SHEET NO.: C40 17775" RCP I \1 1\ 1 Future A Village of WestClay A SECTION 10002 A, (BRENWICK TND COMMUNITIE LLC) SA\TAPY SEWER RLA\ EXISTING Village of WestClay SECTION 10004—A DON'T DIG BLIND "IT'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1 -800- 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IS -69 -1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. 1 P,�IE TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO HELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. 5. ALL WYE, LATERAL AND PROFILE STATIONS ARE FROM THE NEAREST DOWNSTREAM MANHOLE. (MH) 6. WYES AND LATERALS TO BE 6" PIPE UNLESS OTHERWISE SPECIFIED. 7. ALL WYE CONNECTIONS SHALL HAVE A MINIMUM OF FIVE (5) FOOT LATERAL EXTENSION CONNECTED TO THE WYE, OR EXTEND TO THE UTILITY AND DRAINAGE EASEMENT OF THE LOT, WHICHEVER IS GREATER, BUT IN NO CASE SHOULD THE END OF THE LATERALS BE CLOSER THAN FIVE (5) FEET TO THE BUILDING LINE, UNLESS NOTED OTHERWISE. THE END OF THE LATERAL SHALL BE PLUGGED OR CAPPED, UNLESS OTHERWISE NOTED. 8. LATERALS RUNNING TO THE OPPOSITE SIDE OF THE STREET SHALL EXTEND TO THE UTILITY AND DRAINAGE EASEMENT OF THE LOT, BUT IN NO CASE SHOULD THE END OF THE LATERALS BE CLOSER THAN FIVE (5) FEET TO THE BUILDING LINE, UNLESS OTHERWISE NOTED. TBM #44 USGS BENCHMARK CUT "X" NORTH BONNET BOLT IN FIRE HYDRANT EAST SIDE HOOVER RD. ±100' SOUTH OF CLARIDGE FARM ENTRANCE. ELEVATION 893.39 Sheet Detail Descri R ti o____on n Number C802 1 Precast Reinforced Concrete Manhole C802 5 Sanitary Sewer Bedding Detail C802 6 Service Connection for Main Sewer C802 7 Wye Lateral Capping Detail ALL SANITARY SEWER LATERALS TO HAVE FULL DEPTH GRANULAR BACKALL FROM RIGHT OF WAY TO RIGHT OF WAY. IN ADDITION, ALL BACKFILL WITHIN RIGHT OF WAY MUST BE MECHANICALLY COMPACTED IN LIFTS. SCALE: 1"=50' 910 905 900 895 890 885 880 875 870 352' 0.45% 8 "PVC w 0 Cr) ONO w (n (_3 z z 20.5' 0.45% EX. 12" RCP INV- 891.1± 8 "PVC SA\TARY SEWER PROFILE 0 N 343' 0.45% CONNECT TO EXISTING 8 "PVC CONTRACTOR TO FIELD VERIFY INVERT PRIOR TO-CONSTRUCTION, I� I R,GL1E Existing Grade New Grade Granular Backfill CO 00 co N00 N 00 00 cO o O zZo zz w O Chf (f) O w EX. 8" PVC (NE) 48' OF EXISTING 8."..... PVC .....STUB ....Q._4.5. EX. 8" PVC NW) HORZ.: 1 =50' SCALE VERT.: 1"=5' 910 905 900 895 890 885 880 875 870 V No. 0000075 STATE OF 4/ /111NIIIiiiitlo DATE: 11/12/03 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF THE SCHNEIDER CORPORATION, AND ARE NOT TO BE USED OR REPRODUCED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF THE SCHNEIDER CORPORATION. COPYRIGHTED BY THE SCHNEIDER CORP. (2003) Schneider THE SCHNEIDER CORPORATION 12821 E. New Market Street Suite 100 Carmel, IN 46032 Telephone: 317.569.8112 Fax: 317.826.6410 www.schneidercorp.com Architecture Civil Engineering Environmental Engineering Geotechnical Services GIS LIS Home Builder Services Interior Design Land Surveying Landscape Architecture Transportation Engineering