HomeMy WebLinkAbout07050001 Westmont Sec. 1, Large Plan pg. 04N ME UPSTREAM STR. M DOWNSTREAM STR. Al 1 DOWNSTREAM INV. UPSTREAM INV. UPSTRFAM LEN.Eld. DOWNSTRFAM LEK.12d. PIPE MATERIAL PIPE DIAMETER CONC. END SECTION 100 101 892.90 49 PIPE 18 ,1EARD INLET 101 102 100 899.00 892.50 893.50 70 49 PIPE 18 INLET 102/MANHOLE 103 101 898.18 893.00 893.88 40 70 PIPE 15 CURB INLET 103 104 102 898.18 893.60 894.27 41 40 PIPE 12 CURB INLET W/MANHOLE 104 105 103 898.34 893.98 894.58 30 41 PIPE 12 CURB INLET 105 104 898.32 894.37 30 PIPE 12 '1rARD INLET 106 103 898.00 893.98 85 PIPE 12 OUTLET CONTROL STR. 107 108 896.60 892.13 92 PIPE 24 CONC. END SECTION 108 107 892.50 92 PIPE 24 CONC. END SECTION 109 110 893.00 48 PIPE 18 OUTLET CONTROL STR. 110 109 896.70 892.55 48 PIPE 18 CONC. END SECTION 111 112 892.50 116 PIPE 36 YARD INLET 112 113 111 898.50 892.50 893.60 329 116 PIPE 36 YARD INLET 113 114 112 899.70 893.48 894.80 107 329 PIPE 36 YARD INLET 114 115 113 900.00 894.47 895.24 111 107 PIPE 30 YARD INLET 115 116 114 901.40 894.80 895.38 36 111 PIPE 24 (CATH BASIN) CURB INLET W/ MANHOLE 116 117 115 900.55 895.24 895.51 32 36 PIPE 24 CURB INLET 117 118 116 900.55 895.38 896.11 150 32 PIPE 24 YARD INLET 118 117 899.50 895.51 150 PIPE 24 (CATH BASIN) CURB INLET W/ MANHOLE 119 120 114 899.97 895.11 895.71 30 170 PIPE 24 CURB INLET 120 121 119 899.97 895.62 897.25 80 30 PIPE 21 YARD INLET 121 122 120 900.30 896.55 897.25 153 80 PIPE 21 YARD INLET 122 121 900.00 896.79 153 PIPE 18 (CATH BASIN) CURB INLET W/ MANHOLE 123 124 113 900.95 894.57 897.30 30 170 PIPE 12 CURB INLET 124 123 900.95 897.00 30 PIPE 12 CONC. ENO SECTION 125 125A 892.50 67 PIPE 18 MANHOLE 125A 125 126 901.20 892.50 894.69 55 67 PIPE 18 (CATH BASIN) CURB INLET W/ MANHOLE 126 127 125A 900.24 893.75 895.21 75 55 PIPE 18 CURB INLET W/ MANHOLE 127 128 126 899.80 894.79 895.40 30 75 PIPE 15 CURB INLET 128 127 899.80 895.31 30 PIPE 12 WINGWALL 129 130 893.00 125 PIPE 12X6 WINGWALL 130 129 893.60 125 PIPE 12X6 CONC. END SECTION 131 132 893.00 180 PIPE 21 (CATH BASIN) CURB INLET W/I MANHOLE 13 133 131 902.37 893.00 893.58 40 180 PIPE 18 CURB INLET W/ MA NHOLE 133 134 132 902.37 893.50 894.00 214 40 PIPE 18 OUTLET CONTROL. STRUCTRE 134 133 894.00 214 PIPE 18 CONC. END SECTION 135 136 894.00 32 PIPE 18 MANHOLE 136 137 135 899.30 894.00 894.66 153 32 PIPE 18 MANHOLE 137 138 136 904.30 894.20 894.85 30 153 PIPE 18 (CATH BASIN) CURB INLET W/ MANH 138 139 137 903.49 894.26 895.04 32 30 PIPE 18 CURB INLET WMANHOLE 139 140 138 903.49 894.45 895.65 170 32 PIPE 15 YARD INLET 140 139 899.00 895.14 170 PIPE 15 CONC. END SECTION 141 142 894.59 40 PIPE 15 YARD INLET 142 STUB 141 900.50 894.00 894.59 8 4.0 PIPE 15 CONC. END SECTION 143 144 893.00 80 PIPE 18 YARD INLET 144 145 143 898.00 893.00 894.20 111 80 PIPE 18 YARD INLET 145 146 144 898.00 894.20 895.31 190 180 PIPE 12 YARD INLET 146 145 897.40 894.68 120 PIPE 12 (CAIN BASIN) CURB INLET W/ MANHOLE 147 148 145 902.08 894.30 895.50 30 140 PIPE 15 CURB INLET 148 147 902.08 897.50 30 PIPE 12 CONC. END SECTION 149 150 894.00 175 PIPE 18 (CATH BASIN) CURB INLET W/ MANHOLE 150 151 149 901.47 894.00 895.12 36 175 PIPE 15 CURB INLET 151 151A 150 901.47 894.22 898.00 156 36 PIPE 15 YARD INLET 151A 151 895.22 156 36 PIPE 12 15' R.D.E. 125 L.F. 12"x6 'VONSP m DETAIL Slit C 1900.41 898.0 21 903.9 M.F.P.G. 895 55 L.F. ,.6 S.S.D. SWALEte 1.00% 34., R.D.E. H P SWALE I }.00% B.L. 180t1r. °1T -R.C.P 0.40 90 L.F. 6 .,.S.S.D. 898.9 0' B -B ^I D 25 905.0 Q D•E H.P. 898:6 146 89.0 89� 4 89. 9 L.F. 6" S.S.D. 270 L.F. 6" S.S.D 5' L. 904.1 898.0 15' R.D.E 15' R.D.E. 0.45% 1903.371 2 &U.E. 1903.021 20 D. &U.E. �!1 18" R.C.P. 1.06% 40 L.F. 1 R.CP. 0 9 102.671 1902.471 X 894. Igo ($99.31 H.P. 4 +37.86 1903.3$1 .1 M.FP.G. =899. POND 2 N.P.= 894.00 2 YEAR ELEV. 895.31 10 YEAR ELEV, 896.03 100 YEAR ELEV.= 897.94 TTOM ELEV. -886,,00 1903.011 0.70% 5 +00 20' D. &U.E. 31 903,8 M.F.P.Oi. =899.3 {902.311 `902.251 175 L.F. 18 C 0.74% 15' R.D.E. 156 L F 12" P. 0 0.30% 15' R.D.E. 20' D. &U.E. 1899.951 20' D. &U.E.. z J Z W O J W W D W F- DRAWN BY: BAH 18 'r NOTES: 1. THE EXISTING WELLS AND SEPTIC SYSTEMS WILL NEED TO BE PROPERLY LOCATED; ABANDONED IN ACCORDANCE WITH ALL APPLICABLE STANDARDS. 2. ALL PADS SHALL BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. 3. ALL EXISTING OFF -SITE DRAIN TILES THAT ARE ENCOUNTERED SHALL BE TIED INTO THE PROPOSED STORM SEWER SYSTEM WITH A POSITIVE OUTFLOW. ANY OF THESE TILES WILL NEED TO BE LOCATED; BREATHERS SET AT THE PROPERTY LINES, CRUSHED OR REMOVED ACROSS THIS SITE. IF ANY TILES EXTEND BEYOND THIS SITE, THEY WILL NEED A POSITIVE OUTLET TO CONTINUE TO FUNCTION. 4. CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 5. CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY. EXISTING POND N.P.= 893.00 2 YEAR ELEV.= 894.96 10 YEAR ELEV.= 895.59 100 YEAR ELEV. 896.89 BOTTOM ELEV. 885.00 6. ALL EXISTING PAVEMENT SHALL BE SAWCUT TO A CLEAN EDGE WHERE NEW PAVEMENT (FOR WIDENING OR FOR AUXILIARY LANES) IS TO BE INSTALLED ADJACENT TO EXISTING PAVEMENTS. 7. MINIMUM FLOOD PROTECTION GRADES OF ALL STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE ANY ADJACENT 100 -YEAR LOCAL OR REGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS, DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER STRUCTURE MEMEBER WHERE FLOOD WATERS CAN ENTER A BUILDING. 8. PER HCSO, THERE IS TO BE NO DRIVEWAY ENCROACHMENTS INTO EASEMENTS BETWEEN LOTS. 9. THE 100 -YEAR ELEVATION OF STORMWATER DETENTION FACILITIES SHALL BE SEPARATED BY NOT LESS THAN 25 FEET FROM ANY BUILDING OR STRUCTURE TO BE OCCUPIED. THE LOWEST ADJACENT GRADE (INCLUDING WALKOUT BASEMENT FLOOR ELEVATION) FOR ALL RESIDENTIAL, COMMERCIAL, OR INDUSTRIAL BUILDINGS SHALL BE SET A MIMIMUM OF 2 FEET ABOVE THE 100 -YEAR POND ELEVATION OR 2 FEET ABOVE THE EMERGENCY OVERFLOW WEIR ELEVATION, WHICHEVER IS HIGHER. IN ADDITION TO THE LOWEST ADJACENT GRADE REQUIREMENTS, ANY BASEMENT FLOOR MUST BE AT LEAST A FOOT ABOVE THE NORMAL WATER LEVEL OF ANY WET BOTTOM POND. SPECIAL CONSIDERATIONS, BASED ON DETAILED GEOTECHNICAL ANALYSIS, SHOULD BE MADE PRIOR TO CONSIDERING PLACEMENT OF ANY BASEMENT BELOW THE 100 -YEAR FLOOD ELEVATION OF AN ADJACENT FLOODING SOURCE OR POND. T.O.B.= 899.00 4 11 4 9 -6 WEIR T.O.B.= 899.00 CONTACT: CARMEL UTILITIES (317) 571 -2648 FOR WATER LOCATES SPILLWAY 897.30 EMERGENCY SPILLWAY POND 2 NOT -TO -SCALE STORM CHART LJ U) 0 N L NOTE: SIDEWALK CURB TO CONNECT TO EXISTING SIDEWALK IN SADDLE CREEK SECTION 2. EX. 10' TBM No. 1 TBM No. 2 THE SUBJECT PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD HAZARD ZONE A AS SAID TRACT PLOTS BY SCALE ON COMMUNITY PANEL NO. 180081- 0205 -F OF THE FLOOD INSURANCE RATE MAPS DATED FEBRUARY 19, 2003. (FFS) NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. WSE= 894.66 BM TBM HISTORY: 1848.01 870 <000 100 874.1 M.F. P.G.= EX. JRL FIELD BOOK: 408, PAGE 134 CAC FIELD BOOK: 414, PAGE 40 REFERENCE BENCHMARK: BENCH NOTES TYPED BY: JWM 6/22/2005 CHECKED BY: RJC 6/23/05 EXISTING GRADE HANDICAPPED RAMP HOLEY MOLEY SAYS 'DIG SAFELY' "IT'S THE LAVA" CALL 2 WORKING DAYS BEFORE YOU DIG 1- 800 -382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IC8 -1 -26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. SCALE: 1 60' LEGEND EXISTING CONTOUR EXISTING SANITARY SEWER EXISTING STORM SEWER PROPO GRADE PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED SWALE LOT NUMBER PAD ELEVATION PAD SIZE 60'Wx60'D (UNLESS OTHERWISE NOTED) MIN. FLOOD PROTECTION GRADE DENOTES 4" SUBSURFACE DRAIN TO LOT DENOTES 6" SUBSURFACE DRAIN ROLL CURB PROPOSED FLOODWAY FLOODWAY FRINGE PER STOEPPELWERTH ASSOCIATES INC., STULTZ ALMOND DRAIN HEC -RAS MODELING DATED NOVEMBER 15, 2007. PROPOSED 100 -YEAR BASE FLOOD ELEVATION PER STOEPPELWERTH ASSOCIATES INC., STULTZ ALMOND DRAIN HEC -RAS MODELING DATED NOVEMBER 15, 2007 (NAVD 88). TWO BENCH LOOPS WERE RAN: JRL RAN THE FIRST LOOP FROM THE HARRISON AT 141ST AND TOWNE TO THE SITE AND THROUGH CONTROL POINTS ON SITE AND BACK. CAC RUN THE SECOND FROM THE HARRISON AT 136TH AND TOWNE TO THE SITE AND THROUGH THE TEMPORARY BENCH MARKS AND BACK. THE ELEVATIONS ON THE HARRISONS CAME FROM A PREVIOUS BENCH LOOP RAN FOR S A JOB NUMBER 41760 LAKESIDE PARK FROM BENCHMARK "LEE 2 AZI LEE 2 AZI- THE STATION IS LOCATED APPROXIMATELY 2.5 MILES NORTHEAST OF ZIONSVILLE; AT THE INTERSECTION OF SHELBOURNE ROAD AND WEST 131ST STREET; IN THE SOUTHEAST QUADRANT OF THE INTERSECTION; SET IN THE TOP OF A CONCRETE POST, LEVEL WITH THE ROADWAY; A DEPARTMENT OF NATURAL RESOURCES BRASS CONTROL STATION TABLET, STAMPED "LEE 2 AZI 1989 ELEVATION: 917.518' (NAVD 88) A HARRISON MONUMENT AT THE INTERSECTION OF 141st STREET AND TOWNE ROAD, SAID HARRISON IS THE WEST QUARTER CORNER OF SECTION 21, TOWNSHIP 18 NORTH, RANGE 3 EAST. ELEVATION: 911.36' (NAVD 88) A HARRISON MONUMENT AT THE INTERSECTION OF 136th STREET AND TOWNE ROAD, SAID HARRISON IS THE SOUTHWEST CORNER OF SECTION 21, TOWNSHIP 18 NORTH, RANGE 3 EAST. ELEVATION: 910.91' (NAVD 88) A CUT "X" AT THE EAST END AND ON THE TOP OF A CENTER CURB ISLAND. SAID CUT "X" IS LOCATED 70 FEET EAST OF THE INTERSECTION OF QUARTER HORSE COURT AND BARREL RACER LANE IN THE WESTWOOD ESTATES SUBDIVISION. ELEVATION: 903.64' (NAVD 88) A RAILROAD SPIKE, 1 FEET ABOVE THE GROUND, IN THE SOUTH SIDE OF POWER POLE No. 774. SAID POLE IS LOCATED 70 FEET EAST OF THE CENTERLINE OF AUTUMN WOODS DRIVE (ENTRANCE OF SADDLE CREEK SUBDIVISION), 40 FEET NORTH OF THE CENTERLINE OF 141st AND 10 FEET NORTHEAST OF A FIRE HYDRANT. ELEVATION: 898.24' (NAVD 88) CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, marks mode upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. 510 STO EPp F o N 19358 -o STATE OF Q �.c� a c s E N 0N• w� m 0 0 I- I- z 0 W W W wQ I- Z 1-- w I- Cr 0 Q Z z° z Q W J 0 W Z ��0 a_ 1 U w H 0 w a: cri a- 0 z 0 CO z 0 1- 0 0 N- 0 0 U) a 0 Lf) c0 X 0 Li 0.) 0 0 0 0_ SHEET NO. CHECKED BY: EEF C201 S A JOB NO. 5241 5PLA CO 00 N 0 0 00 m w H- 0 0 z