HomeMy WebLinkAbout200708816_090_KT_Y07-A1_0.pdf
FLOOR PLAN 1/4"=1'-0" A WALL LEGEND E FLOOR PLAN NOTES D KEY NOTES B A1.0 FLOOR PLAN ABCDEF 12 11 10 9 8 7 6 5 4 3 2 1 7 A8.2 64 DINING PREP DRIVE-THRU KFC COOK WARE A A8.1 UTILITY 5
FREEZER 1 STARTING POINT. ALL SUB-TRADES SHALL USE THIS POINT AS A BEGINNING LAY-OUT (INSIDE FACE OF EXT. STUDS). FIRE EXTINGUISHER LOCATION. REFER TO FLOOR PLAN NOTES ON THIS SHEET.
PIPE BOLLARD. REFER TO SITE DWGS. HOOD WALL, SEE WALL LEGEND. ELECTRICAL MAIN SWITCH BOARD. REFER TO ELECT. DWGS. CO2 FILL BOX LOCATION. METAL THRESHOLD. SPLASH GUARD. SEE DETAIL 7/A6.3.
INSTALLATION SHALL BE COORDINATED WITH HAND SINK INSTALLATION. PROVIDE BLOCKING @WALLS. DOWNSPOUT. CONNECT TO STORM SEWERS. SEE CIVIL DWGS. S.S. CORNER GUARD /WALL CAP, TYP. ALL CORNERS
IN BACK-OF-HOUSE FROM REAR WALL TO THE KITCHEN SIDE OF THE SERVICE COUNTER. SEE DETAIL 10/A6.3. ELECT. PANELS IN 6" FURRED OUT WALL. REFER TO DETAIL 12 /A6.4. 4" DIA. PVC CHASE IN WALL,
SEE DETAIL 19/A6.3. 7 10 12 11 98356412 8"x8" HORIZONTAL OPENING FOR SYRUP TUBES. COORDINATE WALL WALL PENETRATION WITH COUNTER INSTALLER. SEAL CHASE TO COUNTER. SEE 19/A6.3. CHASE WALL
(TYPICAL INTERIOR WALL. SEE WALL LEGEND) LIGHTING CONTROL PANEL. SEE ELECTRICAL DWGS. GAS METER. REFER TO PLUMBING DWGS. 15 A A5.0 VEG. COOLER 8 2 M.A.P.S. LINE SERVING DRY STORAGE 3
14 CHICKEN COOLER KITCHEN TACO BELL COOK 9 A8.2 9 11 A8.3 1 A8.2 10 3 A8.2 5 2 1 A8.3 7 6 A8.3 2 A8.2 7 A8.3 4 8 A8.2 A8.3 35 A8.0 4 1 2 3 10 WASHING A8.0 8 TYPICAL EXTERIOR SHEAR WALL:
2x6 WD STUDS AT 16" O.C. W/1/2" EXTERIOR GRADE PLYWOOD (CDX) SHEATHING (SEE STRUCT. DWGS. FOR ADDITIONAL INFORMATION.) AND R-19 KRAFT-FACED FIBERGLASS BATT INSULATION U.O.N. AT FRONT
AND REAR WALL SURFACES: PROVIDE 1/2" CDX PLYWOOD ON INTERIOR FACE OVER ENTIRE LENGTH OF WALL SURFACE. NAIL PER SHEAR WALL REQUIREMENTS AT SECTIONS INDICATED AS SHEAR WALLS. GYP. BD.
AND OTHER FINISHES SHALL BE APPLIED OVER STRUCTURAL PLYWOOD. WHERE OCCURS. EXTERIOR SHEARWALL ON 7" THICK FOUNDATION WALL @FRONT AND REAR WALLS AND 6-1/2" THICK FOUNDATION WALL @SIDE
WALLS -PER STRUCTURAL. TYPICAL EXTERIOR WALL: 2x6 WD STUDS AT 16" 0.C. W/1/2" EXTERIOR GRADE PLYWOOD (CDX) SHEATHING AND R-19 KRAFT-FACED FIBERGLASS BATT INSULATION U.O.N. TYPICAL EXTERIOR
WALL ON 7" THICK FOUNDATION WALL @FRONT AND REAR WALLS AND 6-1/2" THICK FOUNDATION WALL @SIDE WALLS -PER STRUCTURAL. EXTERIOR FINISH ASSEMBLY (TYP. SHEAR WALLS, TYP. EXTERIOR WALLS and
TYP. TOWER WALLS): -FLUID APPLIED AIR AND MOISTURE BARRIER (SPEC. SECT. 07195). -REINFORCING MESH (SPEC. SECT. 07195). -RIGID INSULATION (SPEC. SECT. 07210). -DRAINABLE INSULATED EXTERIOR
FINISH SYSTEM (SPEC. SECT. 07240). INTERIOR FINISH ASSEMBLY (TYP. SHEAR WALLS and TYP. EXTERIOR WALLS): -1/2" MOISTURE RESISTANT GYPSUM BOARD FROM T.O. SLAB TO 1'-4" AFF (T.O. FOUNDATION
WALL); U.N.O. -1/2" GYPSUM BOARD FROM B.O. FRAMING (T.O. FOUNDATION WALL) TO B.O. TOP TRUSS CHORD; U.N.O. DIMENSIONS: A. B. WINDOWS /DOORS: A. B. FINISH SUBSTRATES: A. B. C. D. DECOR:
A. B. C. D. GENERAL: A. B. C. D. ALL EXTERIOR DIMENSIONS ARE TO FACE OF MASONRY U.O.N. ALL INTERIOR DIMENSIONS ARE THE FACE OF STUD U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC.
DIMENSIONS. DIMENSIONS NOTED AS "CLEAR" OR "HOLD" ARE MIN. REQ'D. NET CLEARANCE FROM FACE OF WALL FINISH. VERIFY FINAL EQUIPMENT SIZES W/VENDOR PRIOR TO INT. WALL FRAMING. SEE SHT. A1.1
FOR WINDOW TYPES AND DOOR SCHEDULE. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING. PROVIDE 1/2" THICK MOISTURE RESISTANT GYP. BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN
LIEU OF GYP. BD., U.O.N. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS. ALL BACK OF HOUSE AND OFFICE
WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, U.O.N. PROVIDE SOLID BLOCKING FOR WALL SUPPORTED ITEMS. SEE A2.0 FOR SEATING PLAN AND DETAILS. SEE A7.0 FOR FLOOR FINISHES. SEE A8.0 -A8.3
FOR WALL FINISHES. SEE A7.1 FOR CEILING FINISHES. PROVIDE THREE FIRE EXTINGUISHERS -(2) 10 lb. BC and (1) 10 lb. ABC -TO COMPLY WITH LOCAL FIRE CODE. LOCATE PER DIRECTION OF FIRE MARSHALL
OR LOCAL AUTHORIZING AGENT. DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ON NON-BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE. ALL ATTACHMENTS
MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO THE FINISH, PER 13/A6.2. ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPROVED METHOD. CONTACT FOR STO CORP.:
TIM SALERNO 800-628-2738 x6502 (phone) 321-978-0267 (fax) tsalerno@stocorp.com DASHED LINE INDICATES INTERIOR SUBSTRATE LOCATION. ALL WALLS SHALL BE AS INDICATED EXCEPT FROM TOP OF SLAB
TO 12" ABOVE SLAB SHALL BE 1/2" MOISTURE RESISTANT GYPSUM BOARD, U.O.N. THIS NOTE DOES NOT APPLY TO INTERIOR FACE OF RESTROOM WALLS. INTERIOR SOUND-RATED WALL: CONSTRUCT TYPICAL INTERIOR
WALL W/3-1/2" UNFACED FIBERGLASS BATT INSULATION. TYPICAL INTERIOR WALL: 2x4 NOM. WOOD STUDS AT 16" O.C. (6" NOM. or 8" NOM. WHERE NOTED). AT RESTROOMS: NATIONAL GYPSUM -5/8" HI-IMPACT
BRAND XP WALLBOARD. TYPE X CORE. NO SUBSTITUTIONS ALLOWED. AT KITCHEN: 1/2" CDX PLYWOOD W/FRP SURFACE FINISH. AT ALL OTHER FRAME WALL CONDITIONS: 1/2" GYPSUM WALLBOARD FINISHED AS SCHEDULED.
HOODWALL: TYP. EXTERIOR WALL WITH 20 GAGE S.S. PANEL BEHIND HOOD. REFER TO DETAIL 2/M3.0 FOR EXTENTS OF S.S. PANEL. 13 4 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE
NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 6'-0" 4'-0" 10'-0" 4'-0" 6'-0" 5'-4" 6'-0" 2'-0" 3'-10" 2'-2"
14'-0" 6'-0" 5'-4" 6'-0" 75'-4" 27'-8" 18'-0" 29'-8" 4'-4" 4'-4" 5'-4" 2'-8" 6'-0" 2'-4" 4'-0" 6'-0" 4'-0" 6'-0" 2'-8" 11'-0" 14'-0" 11'-0" 36'-0" 2'-4" 3'-4" 8'-0" 6'-0" 8'-0" 4'-0"
10'-0" 4'-0" 7'-0" 6'-0" 9'-0" 6'-0" 7'-4" 6" 4'-8" 4'-8" 2'-0" 4'-8" 3'-8" 3'-0" 5'-4" 24'-8" 15'-512" 14'-712" 7'-0" 3'-6" 22'-0" 18'-0" 35'-4" 4'-1112'-81 2" 6'-11 2" 2'-91 2" 8'-61
4'-9" 2" 2" 3'-0" 1'-101 3'-6" 2'-31 2" 2" 4'-2" 1'-412" 4'-812" 1'-10" 7'-3" 2'-612" 5'-1014" 2'-9" D A5.1 C A5.1 B A5.0 J A5.4 E A5.2 F A5.2 H A5.3 G A5.3 C A5.1 SIM. M.O. M.O. M.O.
M.O. 2'-8" M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. M.O. 7 7 3 1 4 5 5 5 6 6 55 3 3 8 99 9 9 9 99 10 10 10 10 10 10 10 10 10 11 15 12 13 14 3'-8" 1'-10" 22'-0" 4'-2"
HOOD HOOD LOCATION LOCATION 2 2 5'-8" 6'-4" 9 B A5.0 A A5.0 F A5.2 16 16 39 29'-0" 3'-514" 2'-1112" F A5.2 F A5.2 6 89'-4" 10 6-25-09 REVISION 10 1'-412"