HomeMy WebLinkAbout200708816_190_KT_Y07-A6_0.pdf A6.0 CONSTRUCTION DETAILS ROOF SEALED PIPE FLASHING 1 1/2"=1'-0" 12 EXHAUST FAN CURB N.T.S. 19 SLEEPER SUPPORT 1 1/2"=1'-0" 15 EXHAUST FAN CURB 1 1/2" = 1'-0" 18 HVAC CURB 3"=1'-0" 14 MULTIPLE PIPE FLASHING GUTTER DETAIL N.T.S. 13 1 1/2" = 1'-0" 9 WATER HEATER FLUE SUPPORT N.T.S. 20 ROOFING PROTECTION 1-1/2"=1'-0" 16 CONN. @STUD AND @BLOCKING 3" =1'-0" 8 SCUPPER THRU COOLER WALL 3" = 1'-0" 2 (1) -H3 SIMPSON @EA. STUD AND (2) -H3 SIMPSON CONNECTIONS AT EA. STUD FOR CANOPY (2) -2x6 STUDS EACH SIDE OF BLOCKING ROOF DECK LEDGER OR TRUSS. SEE PLAN. (2) 2x12 WD CURB OVER 2x SECURED TO DECK BASE FLASHING SCREW THRU NEOPRENE WASHER , 3 PER SIDE 1" HEAD NAIL @6" O.C. FILL AREA AROUND PIPING W/FOAM INSULATION TO SEAL SPACES MIN. 24 GA. G.I. PIPE ENCLOSURE COVER MULTI PIPE GROUPING -PIPE SLOPING DOWN AWAY FROM SHROUD ROOF MEMBRANE NOTE: GUTTER & DOWNSPOUTS SHALL BE SIZED BY LOCAL REQUIREMENTS ROOFING MEMBRANE ROOF TOP APPLIANCE EMITTING GREASE SHEET METAL FLASHING-WRAPS TOP & SIDES OF CURB, EXTENDING OVER BASE FLASHING BASE FLASHING 5/8" CDX PLYWOOD 8" MIN. BITUTHENE CAP SHEET OVER TOP OF SLEEPER EXTEND DOWN SIDES BY 2" NOTE: SET SUPPORTS ON SOLID NON-RIBBED NEOPRENE, AND SECURE LAG BOLTS THROUGH STEEL/NEOPRENE WASHER MIN. 24 GA. G.I. CAP FLASHING SECURE W/SCREW THRU STEEL/NEOPRENE WASHER AS NEEDED FOR PROPER SECUREMENT (4 SIDES) BASE FLASHING ROOFING MEMBRANE 2x6 @16"O.C. (2)2x12, RIP FOR LEVEL PLATFORM ROOF DECK 10d @6" O.C. (TYPICAL) 2x6 BLOCKING NOTE: RTU SHALL BE LEVEL WITHIN 1/8" OVER LENGTH OF EQUIPMENT HVAC UNIT UNIT COUNTERFLASHING W/NEOPRENE PERIMETER GASKET 1" HEAD NAILS AT 6" O.C. KNOCK-DOWN FLAT METAL CURB -SEE SCOPE OF WORK 5/8" PLYWOOD SECURED TO CURB CURB FLASHING ROOFING MATERIAL OVER RIGID INSULATION W/COVER BOARD TAPERED SLEEPER TO LEVEL CURB 1'-2" 8" MIN. T.O. CURB TO T.O. ROOF STANDARD CURB BASE, FASTEN PER MFR'S RECOMMENDATIONS ELECTRICAL CONDUIT GALVANIZED NAILS @6" O.C. PREFABRICATED CUSTOM CURB FLASHING ROOFING MATERIAL (2) TAPERED 2x12 WD CURB OVER 2x SECURED TO DECK 8" MIN. NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB SCREW THRU NEOPRENE WASHER , 3 PER SIDE 40" MIN. MIN. 16 GA. WELDED DUCT SHEET METAL COUNTER FLASHINGWRAPS TOP & OUTSIDE OF CURB, EXTENDING OVER BASE FLASHING DUCT WRAP -SEE MECHANICAL NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB SEAL WITH APPROVED MATERIAL NEMA 3R FUSED DISCONNECT, MOUNT TO HINGED BASE, SEE ELEC. PRE-FABRICATED VENTILATED CURB EXTENSION HINGED BASE FOR SERVICING/CLEANING. KITCHEN HOOD EXHAUST FAN PREFABRICATED GALV. STEEL CURB W/INSULATION HOT WATER INTAKE OR EXHAUST FLUE PIPE CLAMP-BOLT TO ANGLE, TYP. OF 2 2x2x1/8" ANGLE -LAG BOLT TO PARAPET @BLK'G & CUT & BEND @90° ANGLE BUILDING PARAPET NOTE: FLUES TO BE SEPARATED BY 18" MIN. EXHAUST TO BE 6" HIGHER THAN INTAKE. 14" MIN. CEILING CLOUD ATTACHMENT N.T.S. 17 6" GC TO PROVIDE SIX (6) ADDITIONAL CEILING GRID WIRE HANGERS @EACH CEILING CLOUD. REFER TO REFLECTED CEILING PLAN SCHEDULED CEILING TILE (W/TEGULAR EDGE) NEOPRENE WASHER (FOR TEGULAR TILE OFFSET) UNISTRUT and ALL-THREAD ROD ROD BY ARTWORK VENDOR CEILING CLOUD BY ARTWORK VENDOR ROOFING MEMBRANE TALL PIPE OR CLOSED PIPE LINE STAINLESS STEEL BAND PRE-FAB. VENT STACK FLASHING SEALANT @PENETRATION 2x SOLID BLOCKING STACKED W/DRILLED HOLE FOR PIPE PENETRATION 8" CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 TYPICAL SCUPPER DETAIL 3"=1'-0" 7 ISOMETRIC SEAL CUT EDGES AT SCUPPER OPENING USING WOVEN GLASS FABRIC EMBEDDED INTO AND COVERED WITH FLASHING CEMENT ROOFING SYSTEM -CAP SHEET /FLASHING SHEET FULL BLK'G UNDER FLANGE NOTE: SCUPPER OPENINGS TO BE SIZED PER U.P.C. APPENDIX D AND LOCAL CODE REQUIREMENTS VERTICAL WALL 4" ELASTOMERIC SEALANT ON ALL SIDES 22 GA. G.I. SCUPPER FLASHING-SET PRIMED FLANGES INTO ROOF CEMENT OVER FIELD PLIES AND NAIL FLANGES TO ALL SUBSTRATE SURFACES USING APPROPRIATE FASTENERS BASE FLASHING SYSTEM 3" 22 GA. G.I. CONDUCTOR HEAD 4" 8" YAR005 NOTE: ALL SEAMS @FLASHING TO BE BE SOLDERED 4" 2-1/2" SHED ROOF CAP 3" = 1'-0" 1 FIBERGLASS REINFORCED ASPHALT SHINGLES OVER (2) LAYERS OF 15# FELTS ON 3/4" CDX PLYWOOD SHEATHING W/CLIPS CONT. 2" ALUM. VENT W/INSECT SCREEN REFER TO CONTRACTOR'S OPTION. PRE-FINISHED .040 ALUM. SHED ROOF CAP 8" CONT. 2 x 6 PRESSURE TREATED FASCIA BD. ON BLOCKING CONTRACTOR'S OPTION: USE PRE-FABRICATED SHED ROOF VENT WITH INTERGAL SNOW BAFFLE IN PLACE OF ALUMINUM VENT INSULATION AT CRICKET 3/4" = 1'-0" 5 YAR019 BATT INSULATION -EXTEND IN EXTERIOR WALL TO ABOVE ROOF CRICKET (TYP.) ROOF DRAIN 1-1/2"=1'-0" 6 YAR017 1" HEAD NAIL AT 6-8" O.C. 1/8" MAX.ROOFING PLIES ROOF INSULATION TAPERED TO DRAIN BASE FLASHING SYSTEM INSULATION TAPERED TO DRAIN 4" MIN. OVERFLOW DRAIN WITH LEAD PIPE FLASHING TURNED DOWN INTO DRAIN OPENING ROOF DRAIN -INSTALL PER MFR. SPECS. NOTE: NEITHER PRIMARY NOR OVERFLOW SCUPPERS ARE ALLOWED DURO-LAST DRIP EDGE. INSTALL PER MFR. SPEC. SCUPPER THRU WALL. SEE DETAIL 7/A6.0. DUROLAST ROOFING MEMBRANE OVER 3/4" PLYWOOD OVER 2x12 RAFTER SLOPED FIBER CANT (2) 2"x6" P.T. TOP PLATE 1"x6" EIFS WITH 2"x4" WOOD BLOCKING BEHIND CRICKET 3"=1'-0" 10YAR003 2x WD. BLOCKING ROOFING OVER RIGID INSUL OVER 5/8" PLYWD CRICKET OVER 2x FRAMING PLYWOOD ROOF NOTE: TAPERED FOAM CRICKETS ARE DIAPHRAGM ALLOWED AS AN ALTERNATIVE. SLOPE PER ROOF PLAN COOLER WALL COPING 1"=1'-0" 3 SCUPPER WITH DOWNSPOUT. SOLDIER COURSE. SAW CUT AS NEEDED TO ACCOMODATE THRU WALL SCUPPER THRU WALL FLASHING AND WEEP HOLES DURO-LAST DRIP EDGE. INSTALL PER MFR. SPEC. SCUPPER THRU WALL. SEE DETAIL 7/A6.0. DUROLAST ROOFING MEMBRANE OVER 3/4" PLYWOOD OVER 2x12 RAFTER SLOPED FIBER CANT (2) 2"x6" P.T. TOP PLATE 1"x6" EIFS WITH 2"x4" WOOD BLOCKING BEHIND SOLDIER COURSE. THRU WALL FLASHING AND WEEP HOLES ROOF HATCH SECTION N.T.S. 4 YAR014 8" 8'-2" A.F.F. BOT. OF OPENING ROOF ACCESS HATCH, 2'-6" X 3'-0". SEE EQUIPMENT SCHEDULE. ALUMINUM LADDER W/1/8" MOLDED POLYURETHANE SAFETY CAP. SEE EQUIPMENT SCHEDULE. DUROLAST ROOF MEMBRANE TRUSS, SEE STRUCTURAL FRP OVER 5/8" EXTERIOR GRADE PLYWD. OVER 2x4 STUDS @16" O.C. SUSPENDED CEILING 4" 4" 3 1/2" 1/2" R7 1/8" 5" .036 SEAMLESS COMMERCIAL ALUMINUM GUTTER MASONRY TIES @16" VERTICAL AND 24" HORIZONTAL MASONRY TIES @16" VERTICAL AND 24" HORIZONTAL