HomeMy WebLinkAbout200708816_250_KT_Y07-A7_1.pdf
REFLECTED CEILING PLAN 1/4"=1'-0" A NOT USED F CEILING SYMBOL LEGEND E REFLECTED CEILING PLAN NOTES D KEY NOTES B REFER TO ROOM FINISH SCHEDULE (SHT A7.2) FOR CLG. FINISHES. ACOUSTICAL
PANEL INSTALLATION: INSTALL ACOUSTICAL PANELS WITH EDGES IN CLOSE CONTACT WITH METAL SUPPORTS AND IN TRUE ALIGNMENT. ALLOWABLE VARIATIONS FROM FLAT AND LEVEL SURFACE: 1/8" IN 10'-0"
MAX. ALLOWABLE VARIATIONS FROM PLUMB OF GRID MEMBERS: AS CAUSED BY ECCENTRIC LOADS, 2° MAX. INSTALL SYSTEM AFTER MAJOR ABOVE CLG. WORK IS COMPLETE. COORD LOCATIONS OF HANGERS WITH RELATED
WORK. SEE SPECS FOR ADDITIONAL INFORMATION. SUBSTRATE SHALL BE 1/2" THICK GYP BD. SEE ELECT. DWGS. FOR FIXTURE SCHED. PROVIDE ESCUTCHEON PLATES AND SEALANT AT ALL UTILITY PENETRATIONS
INTO WALLS, CEILINGS AND FLOORS. DOO NOT USE CAULKS OR EXPANDING FOAM FOR SEALANT. DIMENSIONS: A. CEILING FINISHES: A. SUSPENDED CEILING: A. B. C. D. E. GYPSUM BOARD CEILING: A. ELECTRICAL:
A. GENERAL NOTES: A. 1 CEILING GRID STARTING POINT. WALK-IN COOLER BULKHEAD AT 7'-8". NON-INSULATED BUNDLED SYRUP LINES FOR DRINK SYSTEM. SEE DETAIL 17/A6.3. ALSO SEE SCOPE OF WORK.
6" Ø PVC STUB THROUGH CEILING, SEE DETAIL 18/A6.3. HOOD. FOR ROUGH FRAMING OPENINGS SEE AIR DEVICE SCHED. (TYP. AT RESTROOMS). RAISE THIS SECTION OF THE SUSPENDED CEILING TO 8'-10" A.F.F.
M.A.P.S. LINE VERTICAL CHASE THRU CEILING. MENU BOARD. SEE SCOPE OF WORK. MENU BOARD BULKHEAD -BOTTOM OF SOFFIT AT 8'-0" A.F.F. SEE DETAIL 1/A6.3. SERVING COUNTER SOFFIT. SEE DETAIL
1/A6.3. SPEAKER. PENDANT LTG -CENTER OVER TABLE TOP (TYP). EXTERIOR WALL LIGHT FIXTURES, SEE ELEVATIONS AND ELECT. DWGS. KFC "CLOUD". SEE SCOPE OF WORK. REFER TO DETAIL 17 /A6.0 FOR
MOUNTING DETAIL. ELLIPTICAL SOFFIT. COORDINATE LOCATION W/SEATING PLAN A/A2.0. REFER TO SCOPE OF WORK. 23456789 10 11 12 13 14 17 18 19 15 ALL DIMENSIONS ARE TO FACE OF FINISH AND C
OF FIXTURES U.O.N. A7.1 REFLECTED CEILING PLAN ABCDEF 12 11 10 9 8 7 6 5 4 3 2 1 SECURITY STROBE LIGHT, SEE ELECT. DWGS. FAN COIL. 6" X 6" STAINLESS STEEL CHASE ALONG WALL FOR ICE MACHINE
REFRIGERANT LINES: CEILING TO TOP OF ICE MACHINE. PUB SIGN. SEE ELECTRICAL SHEETS. CASE CEILING PENETRATIONS FOR A CLEAN INSTALLATION. CEILING DIFFUSER (TYP.) EXPOSED DUCTWORK. PAINT
P-7 TO MATCH ADJACENT CEILING. KITCHEN WALL FINISH @CEILING. SEE DETAIL 2/A6.3. WALL DIFFUSER. PAINT P-1 TO MATCH SOFFIT. FIXTURE, TRACK MOUNTED (CEILING MOUNTED) (WALL MOUNTED) EMERGENCY
LIGHTS DOWNLIGHT PENDANT OR DIRECTIONAL PENDANT FIXTURE SUSPENDED PENDENT (BY WALK-IN MFR.) DOWNLIGHT @WALK-IN EXIT LIGHT EXIT LIGHT FLUORESCENT LIGHT FLUORESCENT LIGHT 2'-0" x 4'-0"
FIXTURE FIXTURE 1'-0" x 4'-0" SUPPLY DIFFUSER HVAC PERFORATED HVAC RETURN GRILLE HVAC SUPPLY DIFFUSER HVAC SUPPLY DIFFUSER STROBE LIGHT BACK DOOR SECURITY SPEAKER 12" EXHAUST FAN EXTERIOR
WALL FIXTURE S 8'-4" CL-3 CL-2 10'-10" CL-2 10'-0" 8'-0" CL-2 CL-1 8'-0" CL-2 7'-0" CL-2 10'-0" CL-4 9'-0" CL-3 P-1 P-1 P-1 P-7 P-8 P-8 P-2 6 14 1'-0" 1'-2" 1 19 13 14 9 10 11 17 5 2
19 4 L 20 12 12 13'-9" 4'-4" 2'-2" 6 22 21 22 23 23 3 5 10-0" CL-4 10'-0" CL-4 8'-0" CL-2 15 P-2 1'-4" 12 12 16 16 24 14 20 21 18 18 3'-912" 3'-11" 3'-3" 3'-0" 2'-9" 1'-2" 10'-10" 5'-4"
3'-1" 2'-0" 3'-0" 8'-4" P-9 3'-212" 4'-712" 1'-5" 3'-1" 13 10'-4" 9'-11" 7'-312" 9'-11" 7'-212" 6'-1" 6'-1" 12 16 8 8 16 14 S S S S S 7 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE
NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 14 18 8'-2" CL-2 P-8 1'-0" 14 14 14 14 14 14
6 6 6 24 9'-8" CL-2 P-8 21 13 TYP. TYP. TYP. TYP. 10 6-25-09 REVISION 10