HVAC UNIT SCHEDULE 1 MECHANICAL SYMBOLS 12 AIR BALANCE SCHEDULE CFM 4 GENERAL NOTES 10 AIR DEVICE SCHEDULE 3 MARK XX-XXX QUANTITY DIFFUSER TYPE MOUNTING DUTY MATERIAL SIZE NECK CEILING
GRID OR DIFFUSER FACE SIZE RANGE (NO.) & AIR PATTERNCFM REGISTER GRILL LAY-IN SUPPLY RETURN EXHAUST ALUMINUM STEEL SURFACE MANUFACTURER MODEL NUMBER REMARKS NOTES: DIFFUSERS IN SURFACE
MOUNTED CEILINGS SHALL BE PROVIDED WITH OPPOSED BLADE DAMPERS. SEE ARCHITECTURAL DRAWINGS FOR CEILING TYPES. ITEM OA RA SA EA PRESSURE EF-1 ------2200 -2200 S-2 2 6"Ø 10"Ø X (2) 360°
0-250 X X X METAL-AIRE /T I T U S 3 1 0 0 A /T M R -A A ADJUSTABLE CONE DIFFUSER HORIZONTAL POSITION S-3 9 12x12 24x24 X (3)3W,(6)4W 0-1000 X X X METAL-AIRE /TITUS 5000-6 /TDC-AA FRN
SQR TO RND ADAPTER R-1 4 22x22 24x24 X (4) 0-1900 X X X METAL-AIRE /TITUS CC5-FB-TB /50FF FULLY REMOVABLE FACE EF-2 ------2000 -2000 EF-3 ------732 -732 RTU-1 2400 3600 6000 --+2400
RTU-2 2880 4320 7200 --+2880 TOTAL +5280 7920 3200 -5082 +198 SYMBOL & ABBREV. DESCRIPTION CONTRACTOR CEILING AIR CONDITIONING BACK DRAFT DAMPER CIRCUIT BREAKER CONNECT/CONNECTION CONTINUATION
DISCONNECT DETAIL EXHAUST FAN GAGE/GAUGE EXISTING CUBIC FEET PER MINUTE DOWN THRU ROOF CB BDD A/C , AC CLG. CONN. CONT'R CONT. DET. CFM DTR DISC. EF GA. (E) MECHANICAL OUTSIDE AIR NEW
STAINLESS STEEL OPPOSED BLADE DAMPER MANUFACTURER TYPICAL UP THRU ROOF UNLESS OTHERWISE NOTED HVAC HEATING, VENTILATING, AND AIR CONDITIONING MECH. MFR. OA/OSA S/S OBD (N) UON TYP. UTR
GC GENERAL CONTRACTOR CFM SP RPM MARK XX-XXX EXHAUST FAN SCHEDULE 2 SCREEN D-DR V-BELT BIRD BDD DISC ACCESSORIES STARTER HP ELECT REMARKS MODEL NUMBER MANUFACTURER AND EF-3 732 1.0 1296
0.5 120/1 -X X X X STRATOVENT SV-50HP SEE NOTES 3,6,7, & 8 EF-2 2000 1.5 1231 1 208/3 -X X X SV-16HP SEE NOTES 1,2,3,4,5 & 6 EF-1 2200 1.5 1266 1 208/3 -X X X SV-16HP SEE NOTES 1,2,3,4,5
& 6 UL 762 LISTED (GREASE) VENTED ROOF CURB ROOF CURB GREASE TROUGH HINGED ROOF CURB WEATHERPROOF DISCONNECT SWITCH SOLID STATE SPEED CONTROLLER BACKDRAFT DAMPER REMARKS: 1. 2. 3. 4.
5. 6. 7. 8. S-1 2 12x8 13.5x9.75 X (2) 1W 0-400 X X METAL-AIRE /TITUS V4004 /S300FS FURNISH DAMPER/EXTRACTOR, REGISTER TO BE DUCT MOUNTED S-5 4 22x22 24x24 X (4) NO DIREC. 785-1256 X
X X METAL-AIRE /TITUS 7650RAL-6/8FF PERFORATED HINGED FACE, NO FILTER, SEE DETAIL 6/M4.0 EF-4 75 0.5 1050 129W 120/1 -X X X COOK GC-160 SEE NOTES 7,8 S-4 4 9x9 14x14 X (2)2W,(1)4W,(1)3W
0-250 X X METAL-AIRE /TITUS 5000-1 /TDC-AA FRN SQR TO RND ADAPTER M1.0 MECHANICAL SCHEDULES AND NOTES EF-4 ------75 -75 EF-5 ------75 -75 EF-5 75 0.5 1050 129W 120/1 -X X X COOK GC-160
SEE NOTES 7,8 TRANE PACKAGE N.T.S. 8 R-2 2 30x18 32x20 X (2) 0-5000 X X X METAL-AIRE /TITUS SRH /350RL PAINT TO MATCH WALL S-6 5 18x18 24x24 X (3)3W,(2)4W X X X METAL-AIRE /TITUS 5000-6/TDC-AA
FRN SQR TO RND ADAPTER FOR COMPLETE INFORMATION AND PRICING ON THE TRANE HVAC PACKAGE CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. TOLL-FREE PHONE:
(866) YUM-HVAC or (866) 986-4822 FAX: (502) 499-7870 EMAIL: mjcusick@trane.com TRANE HAS AGREED TO TO SUPPLY AN HVAC PACKAGE CONSISTING OF THE ROOF-TOP UNITS, CURBS, THERMOSTATS, TEMPERATURE
SENSORS (REMOTE), AND HUMIDITY SENSORS (REMOTE). RTU'S AS SPECIFIED INCLUDE AN UNPOWERED CONVENIENCE OUTLET (SEE ELECTRICAL) AND AN HACR CIRCUIT BREAKER WHICH PROVIDES UNIT DISCONNECT.
TRANE ALSO HAVE AVAILABLE OPTION PACKAGES WHICH INCLUDE SMOKE DETECTORS AND ENUNCIATORS, ECONOMIZERS, AND RTU VARIATIONS SUCH AS HIGH-EFFICIENCY MODELS. BE PREPARED AT TIME OF ORDER
OR QUOTE REQUEST TO PROVIDE ALL PROJECT DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN MAY NOT MATCH NATIONAL DESIGN. SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL
INFORMATION. CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16
08.25.08 RTU-2 KITCHEN 7200 2880 1.0 5 777 20 244/173 10.6 400 324 2 81 208/3 98 125 2088 TRANE YCD241C3WMA SEE NOTES 1-3, 5-7 MIN O.A. SCHEDULE NOTES: 1. LISTED CAPACITY IS THE STANDARD
STANDARD UNIT'S GROSS COOLING CAPACITY AT 80 DEG. F. DB /67 DEG. F. WB EAT AND 91 DEG. F. AMBIENT. OUTDOOR DESIGN CONDITION, SUMMER 91 DEG. F. & 75 DEG. F WB, WINTER -3 DEG. F. (ARI
STANDARD CONDITIONS.) ADJUST SELECTION BASED ON ACTUAL SITE CONDITIONS AND ACTUAL MOTOR HEAT. 2.. SPECIFIED RTUS ARE DOWN DISCHARGE PACKAGED GAS /ELECTRIC ROOFTOP UNITS WITH MINUMUM
2-STAGE COOLING. INCLUDES THROUGH THE ROOF CURB POWER, GAS & CONDENSATE DRAIN. GAS PIPING SHALL BE FACTORY PIPED WITH SHUT-OFF OUTSIDE OF UNIT. 3. SPECIFIED UNIT INCLUDES HINGED ACCESS
DOORS, 2" PLEATED FILTERS, LOW AMBIENT CONTROL TO 0 DEG. F., MOTORIZED OUTDOOR AIR DAMPER, CIRCUIT BREAKER WITH SINGLE POINT WIRING, HAIL GUARD, AND FACTORY FABRICATED, KNOCK DOWN ROOF
CURB. 4. SPECIFIED UNIT INCLUDES FACTORY INSTALLED HOT GAS REHEAT OPTION INCLUDING REMOTE MOUNTED TEMPERATURE AND HUMIDITY SENSORS AS INDICATED ON THE DRAWINGS 5. SPECIFIED UNIT INCLUDES
SUPPLY AIR TEMPERING CONTROL 6. FOR TRANE VOYAGER UNITS, TRANE SHALL SUPPLY A CTI BOARD TO ALLOW THEIR UNIT TO INTERFACE WITH A "FOREIGN" THERMOSTAT. 7. SPECIFIED UNIT INCLUDES "XDX"
VALVES REQUIRED ON ALL CORPORATE STORES. MARK RTU-X AREA SERVED CFM SUPPLY CFM ESP HP MODEL NUMBER MANUFACTURER AND RPM REMARKS FAN DATA TONS NOM (MBH) TOT/SEN MIN CAP EER MIN STAGE
INPUT OUTPUT WEIGHT UNIT AFUE COOLING CAPACITY HEATING CAPACITY UNIT ELECT DATA PH VOLTS/MCA MOCP MAX (LBS) PHASE (STAGES) RTU-1 DINING 6000 2400 1.0 3 723 15 189/142 11.5 250 203 2
81 208/3 74 80 1498 TRANE YCD181C3LMA SEE NOTES 1-7 LOCATE, CUT AND FRAME ROOF OPENINGS AS SHOWN FOR ALL EXHAUST FANS. IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE USED WHEN LOCATING
EXHAUST FAN ROOF OPENINGS TO ENSURE THAT NO ADDITIONAL OFF-SETS ARE REQUIRED IN THE EXHAUST DUCTWORK. COORDINATE ROOF OPENINGS WITH THE KITCHEN EQUIPMENT. PROVIDE ANY FRAMING REQUIRED
FOR DIFFUSER INSTALLATION IN HARD CEILING. INSTALLATION SHALL CONFORM TO THE ENERGY CONSERVATION DESIGN MANUAL STANDARDS FOR NEW NONRESIDENTIAL BUILDINGS, IF REQUIRED. ALL WORK AND MATERIALS
SHALL COMPLY COMPLY WITH GOVERNING CODES, SAFETY ORDERS AND REGULATIONS. OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES AND INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. PROVIDE CONDUIT
FOR LINE AND LOW VOLTAGE WIRING, LINE VOLTAGE WIRING SWITCHES, AND FINAL CONNECTIONS. ANY EQUIPMENT THAT IS SUBSTITUTED SHALL FIT IN THE SPACE PROVIDED WITH ADEQUATE ROOM FOR SERVICING,
INCLUDING SUBSTITUTE EQUIPMENT NAMED IN THE SPECIFICATIONS. SUBMIT A 1/4" SCALE DRAWING OF ALL EQUIPMENT SUBSTITUTED FOR APPROVAL PRIOR TO INSTALLATION, INCLUDING, BUT NOT LIMINTED TO,
STRUCTURAL AND ARCHITECTURAL IMPACT, CLEARANCE REQUIREMENTS AND UTILITY REQUIREMENTS. FOR INSTALLATION OF RECHARGEABLE REFRIGERANT LINES FROM ICE MACHINE TO CONDENSER ON ROOF, SEE SCOPE
OF WORK. HVAC UNITS SHALL BE MOUNTED LEVEL ON ROOF CURBS. ALL DUCTWORK SHALL BE EXTERNALLY INSULATED, UNLESS NOTED OTHERWISE. ALL SUPPLY /RETURN DUCTS SHALL BE RIGID, WITH THE EXCEPTION
OF THE LAST 14'-0", WHICH MAY BE FLEX. SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN AIR DUCT PRIOR TO TO ANY OUTSIDE AIR CONNECTIONS AND SHALL DEACTIVATE ROOFTOP UNIT UPON SENSING
SMOKE. SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AIR DUCT ONLY WHERE REQUIRED BY CODE. ALL HOOD EXHAUST DUCTS SHALL BE RIGID 16 GA MINIMUM, WELDED DUCT. GRIND ALL WELDS SMOOTH. PROVIDE
3M FIRE BARRIER DUCT WRAP FOR ALL HOOD EXHAUST DUCTS. SEE 15/M4.0. ALL BRANCH DUCTS FEEDING INDIVIDUAL DIFFUSERS SHALL HAVE DAMPERS AT TAKEOFFS FOR AIR BALANCING. PROVIDE ACCESS PANELS
TO DAMPERS. SEE 8/M4.0. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM EXHAUST FANS AND /OR VENTS. SEE 8/M1.0 AND SCOPE OF WORK FOR DESCRIPTION OF HVAC PACKAGE TO BE PURCHASED
THROUGH YUM! BRANDS NATIONAL CONTRACT. FINAL HVAC SYSTEM TESTING AND BALANCING SHALL BE PERFORMED BY INDEPENDENT AGENT CONTRACTED DIRECTLY BY THE OWNER. A RE-TEST IS MANDATORY FOR A
FALSE START (I.E. NO POWER UPON AGENT'S ARRIVAL, EQUIPMENT NOT WIRED, ETC.) AND SHALL BE A COST INCURRED BY THE G.C. IN THE EVENT A SYSTEM /STORE RECEIVES A GRADE OF 5 OR BELOW AS A
RESULT OF THE HVAC SYSTEM PERFORMANCE OR OPERATIONAL DEFICIENCIES, OWNER WILL REQUEST A RE-TEST AND THE COST FOR SAME SHALL BE ALSO INCURRED BY THE GENERAL CONTRACTOR. TRANE PROGRAMMABLE
THERMOSTAT MODEL #BAYSENS019B, PROVIDED WITH TRANE PACKAGE. TRANE THERMOSTAT SENSOR (REMOTE) MODEL #4190-7015, PROVIDED WITH TRANE PACKAGE. TRANE DUCT MOUNTED HUMIDITY SENSOR MODEL #BAYSENS037A,
PROVIDED WITH TRANE PACKAGE. GENERAL: HVAC: 1. 2. 3. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 10 6-25-09 REVISION 10