HomeMy WebLinkAbout200708816_340_KT_Y07-M3_0.pdf KFC /TACO BELL HOOD DETAIL 3/8"=1'-0" 2 KFC TB HOOD SECTION 1/2"=1'-0" 12 HOOD SECTION 1/2" = 1'-0" 4 KFC HOOD 1 0F 2, DUCT TRANSITION DETAIL 1 1/2" = 1'-0" 18 KFC HOOD 2 0F 2, DUCT TRANSITION DETAIL 1 1/2" = 1'-0" 20 M3.0 HOOD DRAWINGS PLANS AND SECTIONS 6" MIN. DISTANCE TO CHANGE OF DIRECTION OF DUCT HOOD TOP 20"x10" TO 14"x12" TRANSITION AT COLLAR 1" FLANGE ON 4" COLLAR FOR DUCT CONNECTION 1" FLANGE DUCT TRANSITION CONNECTION 29" SQUARE FLANGE ON 18" SQUARE DUCT, TOP OF FLANGE TO ROOF-LINE TYP. 23", 18" SQUARE DUCT EXTENDS 2" BELOW ROOF-LINE 18" 14" 6" 25" 14" 4" 6" 20" 6" MIN. 6" MIN. 6" MIN. DISTANCE TO CHANGE OF DIRECTION OF DUCT HOOD TOP 18"x10" TO 14"x12" TRANSITION AT COLLAR 1" FLANGE ON 4" COLLAR FOR DUCT CONNECTION 1" FLANGE DUCT TRANSITION CONNECTION 22.5" SQUARE FLANGE ON 16" SQUARE DUCT, TOP OF FLANGE TO ROOF-LINE TYP. 24", 16" SQUARE DUCT EXTENDS 2" BELOW ROOF-LINE 16" 14" 6" 26" 14" 4" 6" 18" 6" MIN. 6" MIN. RIGHT SIDE VIEW RETHERMALIZER COOKING EQUIPMENT FINISHED FLOOR LINE EXTERIOR WALL DUCT WORK SERVING TYPE II HOODS SHALL BE CONSTRUCTED OF RIGID METALLIC MATERIALS. DUCT CONSTRUCTION, INSTALLATION, BRACING & SUPPORTS SHALL COMPLY WITH CHAPTER 6 OF IMC 2003. DUCT WORK SUBJECT TO POSITIVE PRESSURE & CONVEYING MOISTURELADEN OR WASTE-HEAT-LADEN AIR SHALL BE CONSTRUCTED, JOINED & SEALED IN AN APPROVED MANNER. (IMC 2003, 506.4.2) NEW EXHAUST FAN EF 3 NOTE: SEE SCOPE OF WORK TO DETERMINE RESPONSIBILITIES. SLOPED CONDENSATE BAFFLE 1/2" DRAIN NIPPLE GUTTER 3'-8" 2'-0" EXHAUST DUCT NOT TO EXCEED (2) 90 DEGREE TURNS AND 10'0" IN LENGTH; CONSULT FACTORY FOR REVISED HOOD & FAN EQUIPMENT SPECIFICATIONS REQUIRED FOR SITE ADAPTS74" X 44" S/S WALL PANEL 48" MAX. ROOF LINE SECTION VIEW FINISHED FLOOR LINE REAR WALL PANEL (22 GA. S.S.) EXTERIOR WALL REMOVABLE GREASE TROUGH SLOPE TO RIGHT END 16" HIGH UL LISTED GREASE FILTER CONTINUOUSLY WELDED EXHAUST DUCT SLOPE MIN. 1/4" PER FOOT (2%) TOWARD HOOD WHEN RUN HORIZONTALLY UL LISTED FIRE RATED DUCT WRAP OR 1 HR ENCLOSURE AROUND EXHAUST DUCT 6" AIR GAP ACCESSIBLE, PROTECTED CLEANOUT DOOR NOTE: SEE SCOPE OF WORK TO DETERMINE RESPONSIBILITIES. FRONT INSULATION KIT UL LISTED LIGHT FIXTURE 40" MIN. (N.T.S.) ROOF LINE EXHAUST FAN EF 1 BOTTOM OF TRUSS @11'-8 1/2" A.F.F. (WOOD FRAME CONSTRUCTION) LINE OF CEILING @8'-4" A.F.F. SEE DET. 18/M4.0 FOR DUCT TRANSITION SEE DET. 18/M4.0 FOR DUCT TRANSITION EXHAUST DUCT NOT TO EXCEED (2) 90 DEGREE TURNS AND 10'0" IN LENGTH; CONSULT FACTORY FOR REVISED HOOD & FAN EQUIPMENT SPECIFICATIONS REQUIRED FOR SITE ADAPTS 6" MIN. 2'-0" 4'-0" 6" 6" 6'-6" CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 YMM002 6'-8" 6" FRONT VIEW 2'-0" 4'-6" 1'-10" FIELD CUT J-BOX PRE-WIRED TO LIGHTS INSIDE OF HOOD PLAN VIEW 3" INTEGRAL AIR GAP HOODS ARE SUPPORTED BY 1/2" THREADED ROD THREADED INTO SUPPORT MOUNTING BRACKET (4 TYP.) TOTAL WEIGHT OF HOOD 1: 520 LBS. WALL HOOD # MODEL # LENGTH (IN): WIDTH (IN): HEIGHT (IN): EXHAUST EXHAUST CFM: EXHAUST SP: EXHAUST FPM: EXH. SIZE: FILTERS: ( ) FIRE SUPPRESSION: LIGHT QTY: ( ) SUPPLY CFM: SUPPLY SP: SUPPLY FPM: SUP SIZE: FILTERS: ( ) FILTER TYPE: CONTROL SWITCH: KFC: 1 OF 2 STRATOVENT-SVND2 11'-0" 48" 24" 2200 1.5 1584 20"X10" 2 16" X 16" ANSUL-R102 3 INCANDESCENT NA NA NA NA 5 16" X 20" ALUMINUM NONE NOTES: ALL EXPOSED SURFACES TO BE STAINLESS STEEL. HOOD IS PREPIPED FOR ANSUL AND ETL LISTED. STAINLESS STEEL WALL PANEL TO BE PROVIDED BY HOOD MANUFACTURER. 11'-0" FIELD CUT TOTAL WEIGHT OF HOOD 2: 475 LBS. HOOD # MODEL # LENGTH (IN): WIDTH (IN): HEIGHT (IN): EXHAUST CFM: EXHAUST SP: EXHAUST FPM: EXH. SIZE: FILTERS: ( ) FIRE SUPPRESSION: LIGHT QTY: ( ) SUPPLY CFM: SUPPLY SP: SUPPLY FPM: SUP SIZE: FILTERS: ( ) FILTER TYPE: CONTROL SWITCH: KFC: 2 OF 2 STRATOVENT SVND2 10'-0" 48" 24" 2000 1.5 1600 18" X 10" 0 16" X 16" ANSUL-R102 3 INCANDESCENT NA NA NA NA 6 16" X 20" ALUMINUM NONE 10'-0" 6" MIN 348"L X 116"H STAINLESS STEEL, REAR WALL PANEL, COVERING ENTIRE HOOD WALL AND 18" BEYOND (PROVIDED WITH 1" THICK AIR SPACE ON WOOD FRAME BUILDINGS). 12"W FIRE CABINET 3" INTEGRAL AIR GAP 6" AIR GAP 54"L X 116"H STAINLESS STEEL, RIGHT WALL PANEL (PROVIDED WITH 1" THICK AIR SPACE ON WOOD FRAME BUILDINGS). 10" 10" FINISHED FLOOR SUPPORT ROD TO HOLD WEIGHT OF 56 LBS (TYP. FOR 4) RETHERMALIZER WALL HOOD # MODEL # LENGTH (IN): WIDTH (IN): HEIGHT (IN): EXHAUST CFM: EXHAUST SP: EXHAUST FPM: EXH. SIZE: FILTERS: ( ) FIRE SUPPRESSION: LIGHT QTY: ( ) SUPPLY CFM: SUPPLY SP: SUPPLY FPM: SUP SIZE: FILTERS: ( ) FILTER TYPE: CONTROL SWITCH: TACO BELL VH2 TYPE II 44" 44" 24" 732 .25 1054 10" X 10" 0 NONE 0 NONE NA NA NA NA 1 S/S BAFFLE CONDENSATE BAFFLE NONE 3'-8" 3'-8" GUTTER 3'-8" 1'-0" STAINLESS STEEL, HOOD WALL PANEL (SUPPLIED BY HOOD MANUFACTURER). 1'-0" 1'-6" KFC HOOD TB HOOD EF 2 OR