Loading...
HomeMy WebLinkAbout200708816_370_KT_Y07-P1_0.pdf 1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. 2. ALL DRAWN WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN PLACE. 3. CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE THE SEWER SYSTEM AS REQUIRED. 4. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODES. PROVIDE DEEP SEAL TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS. 5. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC. AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION. 6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL. 7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR INTAKE. 8. PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION. 9. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE. ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED. 10. PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF EQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE AND RESTRAINING DEVICE FURNISHED BY OWNER. PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF EQUIPMENT OR APPLIANCE. IF GAS PRESSURE GREATER THAN 10"/wc IS USED DOWNSTREAM FROM THE GAS METER. 11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS. 12. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH-IN SCHEDULE & FOR ADDITIONAL WORK TO BE FURNISHED & INSTALLED BY CONTRACTOR. ALL ROUGH-IN PLUMBING AND FINAL CONNECTIONS TO KITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR U.O.N. 13. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS. 14. ALL GAS LINES SHALL BE SUPPORTED SEE SPECS. 15. ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE. 16. PROVIDE WATER HAMMER ARRESTOR FOR ALL HAND SINKS AND URINAL WATER LINES. 17. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE. AIR GAP SHALL BE MINIMUM 2 TIMES THE DIAMETER OF THE INDIRECT DRAIN. 18. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD. SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. 19. COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS. 20. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 5'-0" A.F.F. 21. PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION. 22. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN. THEREFORE, VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR. 23. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N. 24. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT. 25. PROVIDE ESCUTCHEON PLATES AND SEALANT AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS AND FLOORS. DOO NOT USE CAULKS OR EXPANDING FOAM FOR SEALANT. GREASE TRAP DESIGN INFORMATION F PLUMBING FIXTURE SUMMARY D PLUMBING SCHEDULE A GENERAL NOTES E PLUMBING LEGEND C TW FW SD CD HWR HW CWG SS GW XXX ITEM FIXTURE DESCRIPTION MANUFACTURER /MODEL NUMBER F.C.O. FLOOR CLEANOUT OR CLEANOUT TO GRADE FW H.B. TW S.O.C. S.O.V. P.T.R.V. C.V. C.W. B.V. E.C.O. FU BFP EXTERIOR CLEAN OUT COLD WATER BELOW GRADE FILTERED WATER PREMIXED TEMPERATURE WATER SHUT-OFF GAS COCK PRESS-TEMPERATURE RELIEF VALVE SHUT-OFF GATE VALVE BALL VALVE CHECK VALVE HOSE BIBB BACK FLOW PREVENTER FIXTURE UNIT W.C.O. WALL CLEANOUT R.D. Y.B. SYMBOLS ABBREV. DESCRIPTION YARD BOX ROOF DRAIN V.T.R. A.P. V.B.F. V.C.P. A.C.P. C.I. U.T.R. (E) H.D. F.D. F.S. OFD A.F.F. G.L. (N) NEW HUB DRAIN GAS LINE ABOVE FINISHED FLOOR FLOOR SINK OVERFLOW DRAIN CAST IRON VITRIFIED CLAY PIPE UP THRU ROOF ASBESTOS CEMENT PIPE EXISTING FLOOR DRAIN VENT THRU ROOF ACCESS PANEL VENT BELOW FLOOR G CW HW H.W.R. V. C.D. S.D. HOT WATER RETURN CONDENSATE DRAIN SANITARY VENT STORM DRAIN GAS /GAS STUB HOT WATER /HW STUB COLD WATER /CW STUB PLUMBING EQUIPMENT DESIGNATION KITCHEN EQUIPMENT NUMBER: REFER TO SOIL OR WASTE (GREASE WASTE)/WASTE STUB KITCHEN EQUIP. DRAWINGS FOR DESCRIPTION. SOIL OR WASTE (SANITARY)/WASTE STUB X-X 0000 SOIL OR WASTE VENT COLD WATER HOT WATER TEMP'D WATER WASTE FU WATER FU FCO 1 FLOOR CLEANOUT --------------CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER. JOSAM /MODEL: 56000 WADE /MODEL: 6000Z ZURN /MODEL: Z-1400 WCO 1 WALL CLEANOUT --------------CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS PLUG, WITH STAINLESS STEEL ACCESS COVER. JOSAM /MODEL: 58510 WADE /MODEL: 8560E ZURN /MODEL: Z-1446-BP HB 1 HOSE BIBB ----3/4" ------2.5/1 FREEZELESS WALL FAUCET WITH INTEGRAL VACUUM BREAKER, BRONZE CASING MAX PRESSURE OF 125 PSI, SLOPE HOSE BIBB TO DRAIN TO EXTERIOR, INSULATE PIPES IN WALL WOODFORD /MODEL: 19 HD 1 HUB DRAIN 3" 2" ------2 --CAST IRON DEEP SEAL P-TRAP WITH FUNNEL, NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG. JOSAM /MODEL: 88213 WADE /MODEL: 2453EF ZURN /MODEL: Z-1019 L 1 LAVATORY 1-1/4" 1-1/2" ----1/2" 1 1.5 WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT, 4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE. FLAT GRID STRAINER. FAUCET: FURNISHED BY OWNER-INSTALLED BY G.C. SINGLE LEVER TYPE FAUCET, ADA COMPLIANT,DELTA MODEL: #500. SEE 8/P6.0 FOR LAV SUPPORT DETAIL. A.S. LUCERNE/MODEL: 0355.012 KOHLER KINGSTON /MODEL: K-2005 CRANE "HARWICH" /MODEL: 1412V S 1 HAND SINK 1-1/2" 1-1/2" ----1/2" 2 1.5 S-1: STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS. FAUCET W/FOOT VALVE PER DETAIL 7/P6.0. ------S 3 3-COMP. SINK INDIRECT --1/2" 1/2" ----3 SINK, FAUCET, DRAIN & PRE-RINSE KIT ------S 4 PREP SINK INDIRECT --1/2" 1/2" ----3 SINK, FAUCET AND DRAIN ------GI 1 GREASE INTERCEPTOR 6" ------------PROVIDE 1,000 GALLON GREASE INTERCEPTOR OR SIZE AS REQUIRED BY AHJ. SEE CIVIL PLAN FOR EXTERIOR GREASE INTERCEPTOR SIZE AND LOCATION. ------MV 1 MIXING VALVE ----1/2" 1/2" ------THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER, CHECK VALVES SIZE PER PIPE CONNECTIONS. HYDROTEK SERIES HBL LAWLER SERIES 61 LEONARD SERIES 210 ET 1 EXPANSION TANK ----3/4" --------EXPANSION TANK, STEEL, EXPANSION MEMBRANE 150 PSI, 160° F, 12 GALLON CAPACITY. MOUNT EXPANSION TANK WITH CHECK & SHUT OFF VALVES ABOVE WATER HEATER. WATTS SERIES DET AMTROL SERIES ST WILKINS SERIES WXTP BFP 1 BACKFLOW PREVENTOR ----VERIFY ------1 REDUCED PRESSURE ZONE BACKFLOW PREVENTER, CAST BRONZE CONSTRUCTION WITH QUARTER TURN FULL-PORT BALL VALVES AND BRONZE STRAINER. WATTS /MODEL: 009M2QTS WILKINS /MODEL: 975XLS FEBCO /MODEL: 860 SA 1 SHOCK ARRESTOR ----1/2" --------STAINLESS STEEL CASING WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN. SIZED PER PDI-WH201 WADE /SHOKSTOP JOSAM /MODEL: 75000 ZURN /SHOKTROL P1.0 PLUMBING SCHEDULES AND NOTES FS 1 FLOOR SINK 4" 2" ------6 --PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP FLUSH WITH FLOOR TILE. JOSAM /MODEL: JPFS4-PVC ZURN /MODEL: FD-2370-PV4-DS-F ECO 1 EXTERIOR CLEANOUT --------------CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER. JOSAM /MODEL: 56000 WADE /MODEL: 6000Z ZURN /MODEL: Z-1400 S 2 MOP SINK 3" 2" 1/2" 1/2" --3 2.25 MOP SINK: FALCON FABRICTORS MODEL: #CMS002 WITH 48" HIGH S.S. LEFT SIDE AND BACK-SPLASH. FURNISHED BY OWNER, INSTALLED BY GC FAUCET: T & S #B-0674-BSTP, WITH VACUUM BREAKER, FURNISHED BY OWNER-INSTALLED BY G.C. ------WC 1 WATER CLOSET 4" 2" 1/2" ----4 2 KOHLER "HIGHLINE" /MODEL: K-3544-T CRANE "ECONMISER" /MODEL: 3H839 WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE, ELONGATED BOWL, ADA COMPLIANT, 1.6 GPF, WITH OPEN FRONT SEAT LESS COVER, OLSENITE #95 OR EQUIVALENT. FLUSHOMETER TANK: SLOAN FLLUSHMATE OR EQUAL. PROVIDE TANK COVER LOCKS. FLUSH VALVES SHALL BE RIGHT HAND OR LEFT HAND AS REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE REQUIREMENTS GW SS HOSE BIBB/WATER FILTRATION UNIT 2 ----1.0 2.0 ----MOP SINK 2 3 6 2.25 2.25 2.25 2.25 BASED ON 2003 IPC (COMBINATION DRAIN & VENT). *FIXTURE HAS INDIRECT WASTE TO FLOOR SINK 15.75 FU = 18.0 GPM USE 1 1/4" HW SERVICE TOTAL ----82 --33.5 --15.75 FLOOR SINK 5 6 30 --------HUB DRAIN 3 2 6 --------FLOOR DRAIN 8 2 16 --------HOSE BIBB 3 ----2.5/1 4.5 ----3 -COMPARTMENT SINK * 1 ----3 3 3 3 PREP SINK * 1 ----3 3 3 3 HAND SINK 3 2 6 1.5 4.5 1.5 4.5 LAVATORY 2 1 2 1.5 3 1.5 3 WATER CLOSET 3 4 12 2 6 ----TOTAL H.W. F.U. H.W. TOTAL C.W. TOTAL C.W. F.U. F.U. COLD WATER HOT WATER F.U.DRAIN FIXTURE NO. PROBABLE DEMAND 33.5 FU = 25.0 GPM 82 WFU USE 6" SANITARY USE 1-1/2" CW SERVICE FD 1 FLOOR DRAIN 3" 2" ------2 --PVC FLOOR DRAIN, 5" DIA. IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USED FOR THE FIRST 10’-0” FROM THE DRAIN ZURN /MODEL: FD-2210 JOSAM /MODEL: 30003-A WADE /MODEL:1103 WH 1 WATER HEATER ----1-1/4" 1-1/4" ------GAS FIRED WATER HEATER, 98.5% THERMAL EFF., 199,000 BTUH INPUT, 100 GAL. STORAGE TANK, 239 GPH @100 DEG. RISE REC. RATE, 3" PVC FLUE & AIR INTAKE, ASME RTD TEMP. & PRESS. REL. VALVE, ELECTRONIC IGNITION SYSTEM , ELETRONIC CONTROLS AND INTEGRAL DIAGNOSTICS. BRADFORD WHITE /EF-100T-199E-3N(A) ----CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 UR 1 URINAL 2" 1-1/2" 3/4" ----4 5 WHITE VITREOUS CHINA, WALL HUNG, TOP INLET, ADA COMPLIANT, 1.0 GPF, WITH WALL HANGER. FLUSH VALVE: SLOAN ROYAL 186-1, ZURN Z6003 AV-WSI OR DELANEY DL-F452. AM. STD. "LYNBROOK" /MODEL:6601.012 KOHLER "FRESHMAN" /MODEL:K-4989-T CRANE "NEW COLBURN" /MODEL: 4992 HB 2 HOSE BIBB ----3/4" ------2.5/1 WALL FAUCET WITH INTEGRAL VACUUM BREAKER MAX PRESSURE OF 125 PSI WOODFORD /MODEL: 24 RO 1 REVERSE OSMOSIS INDIRECT --1/2" --------REVERSE OSMOSIS FILTER SYSTEM BY OWNER SEE TO DETAIL 9/P6.0 WADE /SHOKSTOP JOSAM /MODEL: 75000 ZURN /SHOKTROL RD 1 ROOF DRAIN 3" ------------CAST IRON ROOF DRAIN WITH FLANGE, FLASHING RING WITH GRAVEL STOP AND CAST IRON DOME. WADE /MODEL: 3003 JOSAM /MODEL: 21503 ZURN /MODEL: Z100 ORD 1 OVERFLOW ROOF DRAIN 3" ------------CAST IRON ROOF DRAIN WITH FLANGE, FLASHING RING WITH GRAVEL STOP AND CAST IRON DOME. PROVIDE WITH 3" STANDPIPE. WADE /MODEL: 3003SD JOSAM /MODEL: 21503-16 ZURN /MODEL: Z100-W3 DN 1 DOWNSPOUT NOZZLE 3" ------------CAST BRONZE DOWNSPOUT NOZZLE WITH NO HUB OUTLET AND FLANGE TO SECURE NOZZLE TO WALL. WADE /MODEL: 3943 JOSAM /MODEL: 25013 ZURN /MODEL: Z199 URINAL 1 4 4 5 5 --10 10 06.25.09 REVISION 10