HomeMy WebLinkAbout200708816_380_KT_Y07-P2_0.pdf WASTE & VENT PLAN 1/4"=1'-0" A WASTE & VENT PLAN NOTES C KEY NOTES B PROVIDE FLOOR SINK, IN LIEU OF HUB DRAIN, IF REQUIRED BY LOCAL CODE. PROVIDE CONDENSATE LINE AND DRAIN LINE FROM ICE MACHINE TO HD /FS, PROVIDE AIR GAP PER LOCAL CODE. PROVIDE WASTE LINES FROM BEVERAGE UNIT TO HD /FS, PROVIDE AIR GAP PER LOCAL CODE. PROVIDE 3/4" PVC OR COPPER CONDENSATE FROM DRAIN PROVIDED BY VENDOR TO RUN INSIDE WALL AND OUTFALL AT MOP SINK/HUB DRAIN (HEAT ROPE IS SUPPLIED WITH FREEZER CONDENSATE). EXPOSED PORTION OF CONDENSATE SHALL BE COPPER. PVC OR COPPER CONDENSATE DRAIN FROM HVAC UNITS ON ROOF, RUN ABOVE CEILING TO MOP SINK. PIPING SHALL SLOPE 1/4" PER FOOT AND SHALL BE INSULATED WITH 1" CLOSED CELLULAR INSULATION. REFER TO RISER DIAGRAM ON SHEET P5.0 FOR PIPE SIZES. ENTIRE RUN OF DRAIN LINES TO INLET OF EXTERIOR GREASE INTERCEPTOR AND OUTLET OF INTERCEPTOR TO CONNECTION AT SANITARY MAIN SHALL BE SCHEDULE 40 PVC DWV OR AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. FLOW CONTROL FITTING WITH VENT. 4" VENT UP THROUGH ROOF. PIPE 3-COMPARTMENT SINK TO FLOOR SINK WITH AIR GAP PER CODE. 1-1/2" CONDENSATE DRAIN DOWN FROM RTU. SEE DETAIL 13 ON DRAWING P6.0. 123456789 10 P2.0 WASTE AND VENT PLAN RUN DRAIN LINE FROM S/S DRINK MACHINE THRU WALL OP'G. TO OUTFALL AT FS BENEATH D/T DRINK MACHINE.. UNDERGROUND SANITARY PIPE SHALL BE NO HUB CAST IRON FOR THE FIRST 10 FEET FROM CONNECTION TO FLOOR SINK FS-2. 1-1/2" CONDENSATE DRAIN PIPE DOWN TO MOP SINK/HUB DRAIN. PROVIDE AIR GAP AS REQUIRED BY CODE. IF REQUIRED RUN CONDENSATE PIPING TO EXTERIOR DRYWELL, RETENTION AREA OR STORM SEWER AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. WATER HEATER CONDENSATE. SEE DETAIL 2/P6.0. RUN 3" OVERFLOW DRAIN TO WALL AS HIGH AS POSSIBLE & TERMINATE WITH OVERFLOW NOZZLE. SEE SITE DRAWING (UTILITY PLAN C-141) FOR CONTINUATION. 12 11 13 NO ROOF PENETRATIONS PERMITTED WITHIN ROOF WATER PLY. REFER TO ROOF PLAN FOR LOCATIONS. REFER TO RISER DIAGRAM ON SHEET P5.0 FOR ALL WASTE AND VENT SIZES. STORM WATER PIPING IS SIZED FOR A RAINFALL OF 4" PER HOUR. ADJUST ROOF DRAIN (RD-1) SIZE AND STORM PIPE SIZES PER THE LOCAL RAINFALL REQUIREMENTS AND BY THE AUTHORITY HAVING JURISDICTION. PIPE SHALL DISCHARGE OVER DRIVE-THRU ROADWAY CURB OR AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. INSULATE ALL HORIZONTAL RUNS OF STORM DRAINAGE PIPING ABOVE THE CEILING OR EXPOSED WITH 1" CLOSED CELLULAR INSULATION WITH VAPOR BARRIER JACKET THAT CAN BE PAINTED. 4" SECONDARY DRAIN OUTLET SHALL EXTEND 2" BEYOND FINISHED WALL. SEE ARCHITECTURAL DRAWING A4.0 FOR INSTALLATION PROCEDURE AND A4.1 FOR EXACT LOCATION OF DRAIN OUTLET. COORDINATE LOCATION OF STORM WATER PIPING ABOVE CEILING WITH ALL TRADES PRIOR TO INSTALLATION. A. B. C. D. E. F. 14 NOT USED N.T.S. E GW GW CD GW GW GW GW GW CD GW NOT USED N.T.S. D CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16 08.25.08 RD 1 ORD 1 DN 1 ECO 1 5'-0" 6" 4" 4" 3" 3" 3" 3" FCO 1 15 16 DN 1 ECO 1 ECO 1 5