HomeMy WebLinkAbout200708816_420_KT_Y07-P6_0.pdf
LAVATORY SUPPORT N.T.S. 8 RTU CONDENSATE N.T.S. 13 WATER HEATER SCHEDULE N.T.S. 9 P6.0 PLUMBING DETAILS DRINK SYSTEM DETAIL N.T.S. 16 FOOT PEDAL N.T.S. 7 WATER FILTER SYSTEM N.T.S. 4
TEMPERING VALVE N.T.S. 17 WATER FILTRATION SCHEMATIC N.T.S. 6 SYRUP BUNDLE CONFIGURATION N.T.S. 12 DRINK SYSTEM SCHEMATIC N.T.S. 11 WATER HEATER N.T.S. 2 1/2 LINE 1/2 X 3/8 X 3/8 "Y"
1/2 NPT X 1/2 BARB WATER FILTER 1/2" LINE 3/8 LINES TO ICEMAKERS SHUT-OFF VALVES 3/8 BARB FITTINGS ON INLET AND OUTLET CORNELIUS/REMCOR ED300 SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP
SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP SYRUP POWER CONNECTION IN REAR WATER INLET IN REAR ICE DRAIN IN REAR MAKER SYRUP CO2 SECONDARY REGULATOR
55-60 PSI NOTE INSTALL ELECTRICAL, WATER, AND DRAIN IN ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL CODES. EQUIPMENT RATING: ED250 DISPENSER -115V, 3.5 AMPS ED300 DISPENSER -115V, 4.0
AMPS CARBONATOR -115V, 60 Hz, 7.0 AMPS BOOSTER ASSEMBLY -115V. 60 Hz, 6.5 AMPS GENERAL NOTES: CO2 SECONDARY SECONDARY REGULATOR 90-100 PSI 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. OVERALL
FILTER DIMENSIONS: 25-1/2" WIDE x 9" DEEP x 32" HIGH SEE DETAIL SCOPE OF WORK FOR SCOPE DEFINITIONS. ROUGH-INS SHALL BE PROVIDED BY THE CONTRACTOR. INSTALLATION MUST COMPLY WITH ANY
STATE OR LOCAL PLUMBING CODES. THE FILTER MUST BE PROTECTED AGAINST FREEZING. USE ONLY TEFLON (HIGH-LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. DO NOT INSTALL WHERE LINE
PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. SEE THE EQUIPMENT PLAN FOR LOCATION. SEE DETAIL 12 THIS SHEET FOR BUNDLE DETAILS "Y" FOR ICE MACHINES SUPPLY LINES SHALL
BE INSTALLED @FILTER OUTLET. BACKFLOW PREVENTERS FOR FILTER ASSEMBLY ARE PROVIDED. 1/4" CO2 LINE TO PNEUMATIC GATE REGULATOR (LOCATED BEHIND DISPENSER FRONT PANEL). PRESSURE PRESET TO
30-35 MAX PSI. SYRUP LINES, WATER LINES FOR THE CARBONATOR PUMPS, ICEMAKER WATER LINES, CO2 LINE FOR PNEUMATIC GATE AND PLAIN WATER FOR THE DISPENSERS ARE RUN INSIDE THE TUBING BUNDLE.
REMOTE ROOFTOP CONDENSER REMOTE ROOFTOP CONDENSER BULK CO2 TANK REGULATORWATER REGULATOR -60PSI PUMP 100GPH FILTERED SURGE TANK DOUBLE CHECK VALVE PRESSURE SWITCH/RELIEF VALVE WATER
PRSSURE GAGE 60PSIG PRESSURE SETTING 1/2 I.D. LINE 3/8 LINES TO DISPENSERS REGULATOR UNFILTERED BOOSTER TANK BACK ROOM SWITCH-OVER VALVE TYPICAL SYRUP LINE (ONLY 1 SHOWN FOR CLARITY)
CEILING ROOF ICE MAKER CORNELIUS/REMCOR ED250 ICE PORTION CONTROLLER TO ICEMAKER REFRIGERANT LINES FLOOR SINK ICEMAKER DRAIN DISPENSER DRAIN DINING ROOM 3 RECEPT. 115/60/1 20 AMPS EA.
CARBONATOR FLOOR SINK DRINK COUNTER ICEMAKER DRAIN DISPENSER DRAIN PRE-SET CO2 REGULATOR DRAIN IN REAR WATER INLET IN REAR POWER CONNECTION IN REAR AUTO MANUAL AIR VALVE MANUAL DISPENSE
SWITCH TO ICEMAKER CARBONATOR 3 RECEPT. 115/60/1 20 AMPS EACH PRE-SET CO2 REGULATOR -75PSI REFRIGERANT LINES DRIVE THRU SYRUPCO2 FOR FAST GATE SYRUP SYRUP SYRUP WATER LINE TO NON-CARB
SYRUP SYRUP NON-INSULATED SYRUP BUNDLE INCLUDES 17 LINES WATER LINE TO CARB. SYRUP WATER LINE TO CARB. SYRUP SYRUPSCALE-OUT TO ICE MACH.SYRUP SCALE-OUT TO ICE MACH. WATER LINE TO NON-CARB
MV 1 1/2" LINE THERMOMETER DOMESTIC HW DOMESTIC CW CHECK VALVE (TYP) SHUT-OFF VALVE (TYP) 1/2" TEMPERED WATER TO LAVATORIES RTU CD 3" 6" 4" EQUIPMENT CURB RETURN CONDENSATE DRAIN LINE
THROUGH CURB, CONNECT TO MAIN ABOVE CEILING AND TERMINATE 2" ABOVE RIM OF MOP SINK. INSULATE ALL PIPING BEYOND THIS PENETRATION FULL SIZE VENT TO ATMOSPHERE CONNECTION TO DRAIN PAN REMOVABLE
THREADED CAP FOR CLEAN-OUT & WINTER DRAINING SEE WASTE PLAN FOR CONDENSATE LINE BELOW ROOF 1/2" SWEAT W/1/2" MALE ADAPTER NOTE: 1/2" PIPING SHALL BE HARD COPPER LINE, OR BRAIDED STAINLESS
HOSE. SOFT COPPER IS NOT ACCEPTABLE. 1/2" ANGLE STOP VALVE 1/2" HARD COPPER LINE TO SINK FACE OF SINK WALL SINGLE FOOT PEDAL 1/2" WALL STRAP 1/2" SWEAT ELBOW 1/4" X 3" TAPCON HEX HEAD
SCREW 1/2" SWEAT W/1/2" MALE ADAPTER 1/2" SWEAT/3/8" COMPRESSION 1/2" COPPER LINE FROM MIXING VALVE ABOVE 3" FINISH FLOOR 4x4 WELDED BASE PLATE W/(4) 1/2" HILTI KWIK BOLT II OR EQUAL
FLOOR MOUNT UPRIGHT SUPPORT LAVATORY WALL CARBON F1 F2 2 1 KEY NOTES: 21 PARTICULATE POLYPHOSPHATE SILIPHOS 2 3/4" COLD WATER INLET TO 1/2" COPPER LINE AND FITTINGS AT FILTER. 3/4" OUTLET
W/INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE. ALL WORK THIS DETAIL PER DETAILS 6, 11 & 12/P6.0 FILTER LINE F1 SUPPLIES BUNDLED TUBE BY
PEPSI 1. DRIVE THRU DRINK STATION 2. SELF SERVE DRINK STATION 3. FROZEN BEVERAGE DISPENSER 4. ICE TEA BREWER FILTER LINE F2 SUPPLIES _______________________ 1.) (2)BUNN HOT WATER MACHINES
FILTER LINE F2 SUPPLIES BUNDLED TUBE BY PEPSI 1. ICE MACHINES TB5/620-5 WITH SCALE-OUT HIGH FLOW WATER FILTRATION SYSTEM GENERAL NOTES: OVERALL DIMENSIONS 25-1/2" WIDE x 9" DEEP x 32"
HIGH SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION. INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING CODES. THE UNIT MUST BE PROTECTED AGAINST FREEZING. USE ONLY TEFLON (HIGH-LOW
TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. SEE SHT. A2.0 FOR LOCATION. 1. 2. 3. 4.
5. 6. 7. CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: PLOT DATE:KFC /TB 10575 N. Michigan Road Carmel, IN 46032 KT-Y0708.25.08 KT-Y07 JAN08-C 305823 2007088.16
08.25.08 FLUE THRU ROOF -SEE DETAIL 20/A6.0 WATER HEATER PLATFORM PROVIDED BY W.H. MANUFACTURER. FINISHED FLOOR THERMAL EXPANSION TANK BY WATTS -SEE PLUMBING SCHEDULE -STRAP AND SUPPORT
TO WALL SCHEDULE 40 PVC, MINIMIZE TURNS AND TRANSITIONS. GAS COCK VALVE WITH FULL SIZE DIRT LEG 3/4" DRAIN WITH VALVE & CAP COMBINATION TEMPERATURE AND PRESSURE RELIEF PER LOCAL CODE
RUN T&P DISCHARGE FULL SIZE TO HUB DRAIN 22" DEEP HEAT TRAP AIR INTAKE W/INTERNAL INSECT SCREEN PROVIDED BY MFR. SUPPORT VENT PIPE RUNS EVERY 5'-0" VERTICALLY AND EVERY 3'-0" HORIZONTALLY.
OUTLET THERMOMETER PROVIDED BY MFR. LOCATE WITHIN 12" OF W.H. OUTLET. SEE DETAIL 9/P6.0 FOR SCHEDULE OF ITEMS PROVIDED BY W.H. MFR. DRAIN PAN TO HUB DRAIN. P-TRAP AND LINE TO DRAIN PROVIDED
BY MANUFACTURER. LEAVE AIR GAP BETWEEN BOTTOM OF TRAP AND DRAIN. 12 69 11 10 874532 YMF021B 1 5 1-1/4" G 937268 1-1/4" 1-1/2" 1 4 10 11 16 SERVICE CLEARANCES TOP SIDES FRONT 18" 4" 24"
12 15 13 14 13 14 15 16 T 12" MIN. AND 12" ABV. AVERAGE SNOW LEVEL YMF021S * THE FOLLOWING IS INCLUDED IN THE MANIFOLD KIT: QTY DESCRIPTION 1 1 1 1 3 1 1 2 6 1 2 1 1 1 1 1 1 1 1 1 1
1QTY MODEL # DESCRIPTION 1 EF100T199E3N BWC HIGH EFFICIENCY COMMERCIAL WATER HEATER 1 MFK7 MANIFOLD KIT * 1 DET12 EXPANSION TANK 1 HAL ALARM LIGHT W/INSTALLATION INSTRUCTIONS 3/4" BLK
GAS COCK 3/4" BLK UNION 3/4" BLK TEE 3/4" BLK CAP 3/4" x 2 1/2" BLK NIPPLE 3/4" x 4 BLK NIPPLE 3/4" THD BALL VALVE 1 1/2" FX UNION 1 1/2" CXC 90 1 1/2" CXC TEE 1 1/2" BALL VALVES CXC
1 1/2" CHECK VALVES CXC 1 1/2" GALV ST 90 1 1/2" CX ST 90 HPT-507 1/2" P-TRAP 1/2" P4 SMA 1 1/2" x 1 1/2" x 1/2" TEE COPPER DIAL THERMOMETER 1/2" COPPER FEMALE FITTING ADAPTER 3" PVC
90° 1/2" PVC STREET 90° 1/2" PVC 90° ELBOW 1 PK100 STAND TPS028 HOT WATER DISPENSER P721 HOT WATER P721 DISPENSER UTILITY -GENERAL KITCHEN (HOT) POWER SOAK @3 COMP. SINK FLOW ARROW POINT
OF CONNECTION (PEPSI) POINT OF CONNECTION (GC) UTILITY -TOILET ROOMS /GENERAL KITCHEN (COLD) LEGEND RETHERMALIZER KITCHEN EQUIPMENT # (SHEET A2.0) SYSTEM WATER HEATER MAPS LINE N014
C100 B215 Nxxx CARBONATOR 2 CARBONATOR 1 DRIVE-THRU DRINK SYSTEM SELF-SERVE DRINK SYSTEMVALVE MANIFOLD SELF-SERVE ICE MACHINE DRIVE-THRU ICE MACHINE PARTICULATE 5 MICRON 0.5M CARBON
POLYPHOSPHATE SILIPHOS S570 S570 S532 S532 S513 S513 F2 F1 SEE 11/P6.0 FOR PLUMBING CONNECTIONS OF ADDITIONAL EQUIPMENT TO FILTER SYSTEM. SUPPLY MAIN FROM METER BOOSTER PUMP BOOSTER
TANK S592 SELECTO DRINK/ICE FILTRATION R.O. SYSTEM CHEESE MELTER ICE TEA BREWER FROZEN BEV. DISP. S546 S543 TPS029 FROZEN BEVERAGE DISPENSER 3/8" FILTERED WATER LINE 3/8" x 1/4" SHUT
OFF VALVE 3/8" CO2 LINE FILTERED WATER LINE TO D/T DRINK DISPENSER CO2 LINE TO D/T DRINK DISPENSER TEE OFF FROM D/T DRINK DISPENSER CO2 LINE AND RUN TO FBD TEE OFF FROM D/T DRINK DISPENSER
FILTERED WATER LINE AND RUN TO FBD FILTERED WATER AND CO2 LINES VIA SYRUP BUNDLE SEE 11/P6.0 FOR PLUMBING CONNECTIONS OF ADDITIONAL EQUIPMENT TO FILTER SYSTEM. IF TUBES ARE EXPOSED,
PROVIDE STAINLESS STEEL WALL COVER ICE TEA BREWER